Extraction induced by microemulsion breaking as a novel tool for the simultaneous determination of Cd, Mn, Pb and Sb in gasoline samples by ICP-MS and discrete sample introduction

被引:0
|
作者
Vicentino P.O. [1 ,2 ]
Cassella R.J. [1 ]
Leite D. [2 ]
Resano M. [2 ]
机构
[1] Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Centro, Niterói/RJ
[2] Department of Analytical Chemistry, University of Zaragoza, Aragón Institute of Engineering Research (I3A), Pedro Cerbuna 12, Zaragoza
关键词
Extraction induced by microemulsion breaking; Gasoline; ICP-MS; Metals;
D O I
10.1016/j.talanta.2019.120230
中图分类号
学科分类号
摘要
This study reports a simple and efficient method for the simultaneous determination of Cd, Mn, Pb, and Sb at trace levels in gasoline samples by discrete sample introduction in inductively coupled plasma mass spectrometry (ICP-MS), employing the extraction induced by microemulsion breaking as a sample preparation method. In this work, a microemulsion was formed by mixing 0.7 mL of the gasoline sample with 0.28 mL of ethanol and 0.02 mL of 7 mol L−1 HNO3 solution. Afterwards, 0.1 mL of ultrapure water was added to induce microemulsion breaking. This lead to the formation of two different phases: (i) a top organic phase and (ii) a bottom aqueous phase that contained acid, ethanol and the extracted analytes. After that, 20 μL of the bottom phase (extract) was collected, and the analyte concentrations were determined by discrete sample introduction in ICP-MS. Calibration curves with 20 μg L−1 of Rh as an internal standard were set up to each analyte in the range from 1 up to 10 μg L−1, wherein the standard solutions were prepared in the matrix-matched extract (70:25:5, ethanol: deionized water: 7 mol L−1 HNO3 solution). The optimization of the EIMB conditions was carried out by analyzing the effects of the parameters that could affect the extraction efficiency, such as the relation between the nature of the alcohol and the proportion of the volumes of the microemulsion constituents (sample, HNO3 and alcohol), acid concentration, and the water volume used for the microemulsion breaking. The following limits of detection relative to the amount of sample were obtained: 0.03 (Cd), 0.49 (Mn), 0.07 (Pb) and 0.02 (Sb), all of them in μg L−1. The accuracy of the method was evaluated by the analysis of spiked samples, because no certified gasoline reference material is available. The average recoveries achieved for every analyte ranged from 96% to 114%. The developed methodology was successfully applied to the determination of these metals in five commercial gasoline samples. © 2019 Elsevier B.V.
引用
收藏
相关论文
共 18 条
  • [1] Extraction induced by microemulsion breaking as a novel tool for the simultaneous determination of Cd, Mn, Pb and Sb in gasoline samples by ICP-MS and discrete sample introduction
    Vicentino, Priscila O.
    Cassella, Ricardo J.
    Leite, Diego
    Resano, Martin
    TALANTA, 2020, 206
  • [2] Determination of Cd, Cu, Fe, Mn, Pb and Zn in marine environmental samples by ICP-MS
    Petisleam, T
    Chirila, E
    Caradima, Z
    REVISTA DE CHIMIE, 2005, 56 (12): : 1222 - 1225
  • [3] Extraction induced by emulsion breaking as a tool for simultaneous multi-element determination in used lubricating oils by ICP-MS
    He, Yang-Ming
    Zhao, Fang-Fang
    Zhou, Ying
    Ahmad, Farooq
    Ling, Zhao-Xing
    ANALYTICAL METHODS, 2015, 7 (11) : 4493 - 4501
  • [4] Extraction induced by emulsion breaking for the determination of As, Co, Cr, Mn, Mo and Pb in heavy and extra-heavy crude oil samples by ICP-MS
    Wuyke, Henry
    Oropeza, Tomas
    Feo, Llinaber
    ANALYTICAL METHODS, 2017, 9 (07) : 1152 - 1160
  • [5] Fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb in environmental and biological samples and their determination by ICP-MS
    Zhang, Nan
    Peng, Hanyong
    Wang, Shen
    Hu, Bin
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 121 - 128
  • [6] Fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb in environmental and biological samples and their determination by ICP-MS
    Nan Zhang
    Hanyong Peng
    Shen Wang
    Bin Hu
    Microchimica Acta, 2011, 175 : 121 - 128
  • [7] Determination of Mn, Fe, Ni, Cu, Zn, Cd and Pb in seawater using offline extraction and triple quadrupole ICP-MS/MS
    Jackson, S. L.
    Spence, J.
    Janssen, D. J.
    Ross, A. R. S.
    Cullen, J. T.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (02) : 304 - 313
  • [9] Determination of traces of As, Cd, Cr, Hg, Mn, Ni, Sb, Se, Sn and Pb in human hair by triple quadrupole ICP-MS
    Nouioui, Mohamed Anouar
    Milliand, Marie-Laure
    Bessueille-Barbier, Frederique
    Hedhili, Abderrazek
    Ayouni-Derouiche, Linda
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (10) : 954 - 976
  • [10] Advances in the offline trace metal extraction of Mn, Co, Ni, Cu, Cd, and Pb from open ocean seawater samples with determination by sector field ICP-MS analysis
    Queroue, Fabien
    Townsend, Ashley
    van der Merwe, Pier
    Lannuzel, Delphine
    Sarthou, Geraldine
    Bucciarelli, Eva
    Bowie, Andrew
    ANALYTICAL METHODS, 2014, 6 (09) : 2837 - 2847