Insulin sensitivity by oral glucose minimal models: validation against clamp

被引:93
|
作者
Dalla Man, C
Yarasheski, KE
Caumo, A
Robertson, H
Toffolo, G
Polonsky, KS
Cobelli, C
机构
[1] Univ Padua, Dept Informat Engn, I-35131 Padua, Italy
[2] Washington Univ, Sch Med, Div Endocrinol Metab & Lipid Res, St Louis, MO USA
[3] Ist Sci San Raffaele, Milan, Italy
关键词
insulin resistance; oral glucose tolerance test; meal; insulin action; tracer kinetics;
D O I
10.1152/ajpendo.00076.2005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measuring insulin sensitivity in the presence of physiological changes in glucose and insulin concentrations, e. g., during a meal or OGTT, is important to better understand insulin resistance in a variety of metabolic conditions. Recently, two oral minimal models have been proposed to measure overall insulin sensitivity (S-I) and its selective effect on glucose disposal (S-I(*)) from oral tests. S-I and S-I(*) have been successfully validated against multiple tracer meal estimates, but validation against euglycemic hyperinsulinemic clamp estimates is lacking. Here, we do so in 21 subjects who underwent both a multiple-tracer OGTT and a labeled euglycemic hyperinsulinemic clamp. Correlation between minimal-model S-I, S-I(*) and corresponding clamp estimates S-I(*clamp), S-I(*clamp) was satisfactory, respectively r = 0.81, P < 0.001, and r = 0.71, P < 0.001. SI was significantly lower than S I clamp (8.08 +/- 0.89 vs. 13.66 +/- 1.69 10(-4) dl.kg(-1).min(-1) per mu U/ml, P = 0.0002), whereas S-I(*) and S-I(*clamp) were very similar (8.17 +/- 1.59 vs. 8.84 +/- 1.39 10(-4) dl.kg(-1).min(-1) per mu U/ml, P = 0.52). These results add credibility to the oral minimal-model method as a simple and reliable physiological tool to estimate S-I and S-I(*), also in large-scale clinical trials.
引用
收藏
页码:E954 / E959
页数:6
相关论文
共 50 条
  • [41] Insulin release in impaired glucose tolerance - Oral minimal model predicts normal sensitivity to glucose but defective response tinges
    Breda, E
    Toffolo, G
    Polonsky, KS
    Cobelli, C
    DIABETES, 2002, 51 : S227 - S233
  • [42] Estimating insulin sensitivity and β-cell function from the oral glucose tolerance test: validation of a new insulin sensitivity and secretion (ISS) model
    Ha, Joon
    Chung, Stephanie T.
    Springer, Max
    Kim, Joon Young
    Chen, Phil
    Chhabra, Aaryan
    Cree, Melanie G.
    Behn, Cecilia Diniz
    Sumner, Anne E.
    Arslanian, Silva A.
    Sherman, Arthur S.
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2024, 326 (04): : E454 - E471
  • [43] INSULIN SENSITIVITY IN WOMEN WITH GESTATIONAL DIABETES - EUGLYCEMIC CLAMP AND MINIMAL MODEL MEASUREMENTS
    TRIGO, E
    BRUSCHETTA, H
    NADER, I
    DIAZ, J
    SIPOS, G
    BUCHANAN, T
    DIABETES, 1995, 44 : A14 - A14
  • [44] Correlation between insulin sensitivity indizes derived from glucose clamp studies and IMCL content in different rat models of insulin resistance
    Neumann-Haefelin, C
    Kuhlmann, J
    Belz, U
    Juretschke, HP
    Kramer, W
    Herling, AW
    DIABETOLOGIA, 2004, 47 : A200 - A201
  • [45] Good agreement between hyperinsulinemic-euglycemic clamp and 2 hours oral minimal model assessed insulin sensitivity in adolescents
    Carreau, Anne-Marie
    Xie, Danielle
    Garcia-Reyes, Yesenia
    Rahat, Haseeb
    Bartlette, Kai
    Behn, Cecilia Diniz
    Pyle, Laura
    Nadeau, Kristen J.
    Cree-Green, Melanie
    PEDIATRIC DIABETES, 2020, 21 (07) : 1159 - 1168
  • [46] Insulin sensitivity in NIDDM: Insulin modified intravenous glucose tolerance vs isoglycemic hyperinsulinemic clamp
    Mehring, G
    Coates, PA
    Brunel, PC
    Luzio, SD
    Beck, P
    Owens, D
    DIABETOLOGIA, 1997, 40 : 1099 - 1099
  • [47] INSULIN SENSITIVITY IN PATIENTS WITH ARTERIAL INSUFFICIENCY - REEVALUATION WITH THE MULTILEVEL GLUCOSE CLAMP TECHNIQUE
    LUNDGREN, F
    LUNDHOLM, K
    EKROTH, R
    HOLM, J
    SCHERSTEN, T
    CLINICAL PHYSIOLOGY, 1987, 7 (03): : 197 - 207
  • [48] The clamp-like index -: A novel and highly sensitive insulin sensitivity index to calculate hyperinsulinemic clamp glucose infusion rates from oral glucose tolerance tests in nondiabetic subjects
    Anderwald, Christian
    Anderwald-Stadler, Marietta
    Promintzer, Miriam
    Prager, Gerhard
    Mandl, Martina
    Nowotny, Peter
    Bischof, Martin G.
    Wolzt, Michael
    Ludvik, Bernhard
    Kaestenbauer, Thomas
    Pacini, Giovanni
    Luger, Anton
    Krebs, Michael
    DIABETES CARE, 2007, 30 (09) : 2374 - 2380
  • [49] A NEW GLUCOSE CLAMP TECHNIQUE YIELDING A MEASURE OF INSULIN SENSITIVITY INDEPENDENT OF GLYCEMIA
    BERGMAN, RN
    PACINI, G
    FINEGOOD, DT
    CLINICAL RESEARCH, 1982, 30 (01): : A60 - A60
  • [50] Simple estimates of insulin sensitivity in children: Comparison with the gold standard of glucose clamp
    Gungor, N
    Saad, R
    Arslanian, S
    PEDIATRIC RESEARCH, 2002, 51 (04) : 122A - 122A