Insulin sensitivity by oral glucose minimal models: validation against clamp

被引:93
|
作者
Dalla Man, C
Yarasheski, KE
Caumo, A
Robertson, H
Toffolo, G
Polonsky, KS
Cobelli, C
机构
[1] Univ Padua, Dept Informat Engn, I-35131 Padua, Italy
[2] Washington Univ, Sch Med, Div Endocrinol Metab & Lipid Res, St Louis, MO USA
[3] Ist Sci San Raffaele, Milan, Italy
关键词
insulin resistance; oral glucose tolerance test; meal; insulin action; tracer kinetics;
D O I
10.1152/ajpendo.00076.2005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measuring insulin sensitivity in the presence of physiological changes in glucose and insulin concentrations, e. g., during a meal or OGTT, is important to better understand insulin resistance in a variety of metabolic conditions. Recently, two oral minimal models have been proposed to measure overall insulin sensitivity (S-I) and its selective effect on glucose disposal (S-I(*)) from oral tests. S-I and S-I(*) have been successfully validated against multiple tracer meal estimates, but validation against euglycemic hyperinsulinemic clamp estimates is lacking. Here, we do so in 21 subjects who underwent both a multiple-tracer OGTT and a labeled euglycemic hyperinsulinemic clamp. Correlation between minimal-model S-I, S-I(*) and corresponding clamp estimates S-I(*clamp), S-I(*clamp) was satisfactory, respectively r = 0.81, P < 0.001, and r = 0.71, P < 0.001. SI was significantly lower than S I clamp (8.08 +/- 0.89 vs. 13.66 +/- 1.69 10(-4) dl.kg(-1).min(-1) per mu U/ml, P = 0.0002), whereas S-I(*) and S-I(*clamp) were very similar (8.17 +/- 1.59 vs. 8.84 +/- 1.39 10(-4) dl.kg(-1).min(-1) per mu U/ml, P = 0.52). These results add credibility to the oral minimal-model method as a simple and reliable physiological tool to estimate S-I and S-I(*), also in large-scale clinical trials.
引用
收藏
页码:E954 / E959
页数:6
相关论文
共 50 条
  • [31] The intravenous prandial glucose tolerance test (IVPGTT) to measure glucose effectiveness and insulin sensitivity with the minimal models
    Simeoni, M
    Basu, A
    Caumo, A
    Rizza, RA
    Cobelli, C
    DIABETES, 1999, 48 : A288 - A288
  • [32] A NEW GLUCOSE-CLAMP TECHNIQUE AND THE VALIDATION OF THE INSULIN SENSITIVITY INDEX MEASURED BY AN INTRAVENOUS GLUCOSE-TOLERANCE TEST IN DOGS
    COBELLI, C
    PACINI, G
    BERGMAN, RN
    FINEGOOD, DT
    DIABETOLOGIA, 1982, 23 (03) : 296 - 296
  • [33] COMPARISON OF THE MINIMAL MODEL AND HYPERGLYCEMIC CLAMP TECHNIQUES FOR MEASURING INSULIN SENSITIVITY
    KORYTKOWSKI, M
    BERGA, S
    HORWITZ, M
    DIABETES, 1993, 42 : A169 - A169
  • [34] Assessment of peripheral insulin sensitivity from an oral glucose test by a new labelled oral minimal model.
    Man, CD
    Caumo, A
    Basu, R
    Rizza, RA
    Toffolo, G
    Cobelli, C
    DIABETOLOGIA, 2003, 46 : A194 - A194
  • [35] Comparison of Oral Glucose Insulin Sensitivity with Other Insulin Sensitivity Surrogates from Oral Glucose Tolerance Tests in Chinese
    Wu, Chung-Ze
    Pei, Dee
    Su, Ching-Chieh
    Hsiao, Fone-Ching
    Chu, Yi-Min
    Lee, Li-Hsiu
    Wang, Kun
    Hsieh, An-Tsz
    Lin, Juinn-Diann
    Hsia, Te-Lin
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2010, 39 (01) : 4 - 8
  • [36] Minimal model indices of peripheral and hepatic insulin sensitivity from a labeled oral glucose test
    Caumo, A
    Dalla Man, C
    Di Camillo, B
    Basu, R
    Rizza, RA
    Toffolo, G
    Cobelli, C
    DIABETES, 2002, 51 : A350 - A351
  • [37] Insulin sensitivity and plasma glucose appearance profile by oral minimal model in normotensive and normoglycemic humans
    Burattini, Roberto
    Casagrande, Fabrizio
    Di Nardo, Francesco
    Boemi, Massimo
    Morosini, Pierpaolo
    BIOLOGICAL AND MEDICAL DATA ANALYSIS, PROCEEDINGS, 2006, 4345 : 128 - +
  • [38] Metabolite Trajectories during an Oral Glucose Challenge Reveal New Associations with Clamp-Measured Insulin Sensitivity
    Nowak, Christoph
    Sundstrom, Johan
    Salihovic, Samira
    Ganna, Andrea
    Shen, Xia
    Gustafsson, Stefan
    Broeckling, Corey D.
    Prenni, Jessica
    Berne, Christian
    Giedraitis, Vilmantas
    Arnlov, Johan
    Lind, Lars
    Fall, Tove
    Ingelsson, Erik
    DIABETES, 2016, 65 : A398 - A398
  • [39] COMPUTERIZED GLUCOSE CLAMP METHOD FOR THE DETERMINATION OF INSULIN SENSITIVITY IN DIABETIC SUBJECTS
    HARADA, M
    HARANO, Y
    KOJIMA, H
    SUZUKI, M
    FURUSAWA, S
    NISHINO, Y
    UCHIGAKI, T
    HYODO, H
    SHIGETA, Y
    JAPANESE JOURNAL OF MEDICINE, 1987, 26 (01) : 25 - 30
  • [40] Correlation of oral glucose tolerance test-derived estimates of insulin sensitivity with insulin clamp measurements in an African-American cohort
    Cheng, C
    Campbell, KL
    Kushner, H
    Falkner, BE
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2004, 53 (09): : 1107 - 1112