An anatomic coordinate system of the femoral neck for highly reproducible BMD measurements using 3D QCT

被引:42
|
作者
Kang, Y [1 ]
Engelke, K [1 ]
Fuchs, C [1 ]
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
anatomic 3D coordinate system; proximal femur; femoral neck; bone mineral density; cortical thickness;
D O I
10.1016/j.compmedimag.2005.05.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, a procedure for the determination of an anatomically oriented coordinate system of the femoral neck (NCS) in 3D spiral CT datasets is described. The origin of the NCS is centered in the minimal cross-sectional area of the neck. Its three axes are defined as follows: the so called neck axis is perpendicular to this area and points towards the femoral head, the second axis is the principal axis of the minimal cross-sectional area and the third axis is perpendicular to the other two. After a semi-automatic 3D segmentation of the proximal femur the NCS is automatically determined in a two-step minimization procedure. Relative to the coordinate system volumes of interest (VOIs) are positioned in which bone mineral density (BMD) and cortical thickness are analyzed. We investigated intra- and inter-operator precision of the position of the NCS, the BMD in cortical and trabecular VOls, and cortical thickness in nine pelvic CT datasets obtained from clinical routine examinations. We further investigated the effect of increased noise by adding Gaussian distributed noise to measured projections before tomographic reconstruction. The mean precision error (averaged form the results of the nine datasets) of the NCS position was less than 0.5 mm and smaller than 2.25 degrees. There were no significant differences between inter- and intra-operator analyses. Precision errors in trabecular BNID were smaller than 3% in a stack of five 1 mm thin slices cut perpendicularly to the neck axis and smaller than 1% in a spherical VOI encompassing the neck. Relative precision errors for cortical BNID were smaller than 3% for both VOIs. An increase of noise up to a factor of 5 caused a maximal displacement of the NCS origin position by less than I mm and a rotation by less than 2 degrees. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:533 / 541
页数:9
相关论文
共 50 条
  • [21] 3D quantitative computed tomography (QCT) of the spine to assess regional changes of trabecular and cortical BMD.
    Engelke, K.
    Mastmeyer, A.
    Kalender, W. K.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2006, 21 : S223 - S223
  • [22] A hierarchical 3D segmentation method and the definition of vertebral body coordinate systems for QCT of the lumbar spine
    Mastmeyer, Andre
    Engelke, Klaus
    Fuchs, Christina
    Kalender, Willi A.
    MEDICAL IMAGE ANALYSIS, 2006, 10 (04) : 560 - 577
  • [23] BURNCASE 3D: REPRODUCIBLE BURNS-ASSESSMENT USING 3D TECHNOLOGY
    Owen, R.
    Giretzlehner, M.
    Dirnberger, J.
    Haller, H.
    Kamolz, L. P.
    EHEALTH2012 - HEALTH INFORMATICS MEETS EHEALTH - VON DER WISSENSCHAFT ZUR ANWENDUNG UND ZURUCK: MOBILE HEALTH & CARE - GESUNDHEITSVORSORGE IMMER UND UBERALL, 2012, : 185 - 190
  • [24] A portable 3D vision coordinate measurement system using a light pen
    Liu, S.G.
    Peng, K.
    Huang, F.S.
    Zhang, G.X.
    Li, P.
    Key Engineering Materials, 2005, 295-296 : 331 - 336
  • [25] Algorithm for converting 3D objects into rolls using spiral coordinate system
    Shulunov, Vyacheslav R.
    VIRTUAL AND PHYSICAL PROTOTYPING, 2016, 11 (02) : 91 - 97
  • [26] A portable 3D vision coordinate measurement system using a light pen
    Liu, SG
    Peng, K
    Huang, FS
    Zhang, GX
    Li, P
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS VI, 2005, 295-296 : 331 - 336
  • [27] Pre- and postoperative offset and femoral neck version measurements and validation using 3D computed tomography in total hip arthroplasty
    Geijer, Mats
    Kiernan, Sverrir
    Sundberg, Martin
    Flivik, Gunnar
    ACTA RADIOLOGICA OPEN, 2020, 9 (10)
  • [28] 3D Simultaneous Segmentation and Registration of Vertebral Bodies for Accurate BMD Measurements
    Boneta, Lisa
    Shalaby, Ahmed
    Refaey, Ahmed
    Loukhaoukha, Khaled
    Giakos, George
    2017 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2017, : 54 - 58
  • [29] An Intrinsic Coordinate System for 3D Face Registration
    Koppen, W. P.
    Chan, C. H.
    Christmas, W. J.
    Kittler, J.
    2012 21ST INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR 2012), 2012, : 2740 - 2743
  • [30] 3D scanning as a highly precise, reproducible, and minimally invasive method for surface area and volume measurements of scleractinian corals
    Reichert, Jessica
    Schellenberg, Johannes
    Schubert, Patrick
    Wilke, Thomas
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2016, 14 (08): : 518 - 526