摘要
Background: Restoration of a correct biomechanical situation after total hip arthroplasty is important. Purpose: To evaluate proximal femoral symmetry of acetabular and femoral offset and femoral neck anteversion pre- and postoperatively in hip arthroplasty by semi-automated 3D-CT and to validate the software measurements by inter- and intraobserver agreement calculations. Material and Methods: In low-dose CT on 71 patients before and after unilateral total hip arthroplasty, two observers used a digital 3D templating software to measure acetabular offset, true and functional femoral offset, and femoral neck anteversion. Observer agreements were calculated using intraclass correlation. Hip measurements were compared in each patient and between pre- and postoperative measurements. Results: Preoperatively, acetabular offset (2.4 mm), true (2.2 mm), and functional global offset (2.7 mm) were significantly larger on the osteoarthritic side without side-to-side differences for true and functional femoral offset or femoral neck anteversion. Postoperatively, acetabular offset was significantly smaller on the operated side (2.1 mm) with a concomitantly increased true (2.5 mm) and functional femoral offset (1.5 mm), resulting in symmetric true and functional global offsets. There were no differences in postoperative femoral neck anteversion. Inter- and intraobserver agreements were near-perfect, ranging between 0.92 and 0.98 with narrow confidence intervals (0.77-0.98 to 0.94-0.99). Conclusion: Acetabular and concomitantly global offset are generally increased in hip osteoarthritis. Postoperative acetabular offset was reduced, and femoral offset increased to maintain global offset. 3D measurements were reproducible with near-perfect observer agreements. 3D data sets should be used for pre- and postoperative measurements in hip arthroplasty.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Effect of Femoral Offset Loss on Muscle Moment Arms in Total Hip Arthroplasty: A 3D biomechanical analysis
    Rudiger, Hannes
    Parvex, Valerie
    Terrier, Alexandre
    SWISS MEDICAL WEEKLY, 2014, 144 : 38S - 38S
  • [2] Assessment of Total Hip Arthroplasty by Means of Computed Tomography 3D Models and Fracture Risk Evaluation
    Gargiulo, Paolo
    Petursson, Throstur
    Magnusson, Benedikt
    Bifulco, Paolo
    Cesarelli, Mario
    Izzo, Gianluca Mario
    Magnusdottir, Gigja
    Halldorsson, Gretar
    Ludvigsdottir, Gudbjoerg K.
    Tribel, Jan
    Jonsson, Halldor, Jr.
    ARTIFICIAL ORGANS, 2013, 37 (06) : 567 - 573
  • [3] Specificity of estimating femoral anteversion using linea aspera version for total hip arthroplasty A three-dimensional computed tomography study
    Thajudeen, Mohamed Zaim Mohamed
    Merican, Azhar Mahmood
    Hashim, Muhammad Sufian
    Nordin, Abid
    MEDICINE, 2022, 101 (45) : E31398
  • [4] Computed tomography-based automated 3D measurement of femoral version: Validation against standard 2D measurements in symptomatic patients
    Schmaranzer, Florian
    Movahhedi, Mohammadreza
    Singh, Mallika
    Kallini, Jennifer R.
    Nanavati, Andreas K.
    Steppacher, Simon D.
    Heimann, Alexander F.
    Kiapour, Ata M.
    Novais, Eduardo N.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (10) : 2237 - 2248
  • [5] MONITORING BONE DENSITY FROM PATIENTS UNDERGOING TOTAL HIP ARTHROPLASTY USING COMPUTED TOMOGRAPHY AND 3D MODELING TECHNIQUES
    Gargiulo, Paolo
    Helgasson, Benedikt
    Magnusson, Benedikt
    Petursson, Throstur
    Izzo, Gianluca Mario
    Magnusdottir, Gigja
    Halldorsson, Gretar
    Tribel, Jan
    Jonsson, Halldor, Jr.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [6] True femoral anteversion during primary total hip arthroplasty - Use of postoperative computed tomography-based sections
    Suh, KT
    Kang, JH
    Roh, HL
    Moon, KP
    Kim, HJ
    JOURNAL OF ARTHROPLASTY, 2006, 21 (04): : 599 - 605
  • [7] The Utility of Lesser Trochanter Version to Estimate Femoral Anteversion in Total Hip Arthroplasty: A Three-Dimensional Computed Tomography Study
    Thajudeen, Mohamed Zaim bin Mohamed
    Merican, Azhar Mahmood
    Hashim, Muhammad Sufian
    Nordin, Abid
    SURGICAL TECHNIQUES DEVELOPMENT, 2022, 11 (02): : 54 - 61
  • [8] Periprosthetic modelling of femoral component fit using computed tomography data for total hip arthroplasty: A feasibility study
    D. A. Hauser-Kara
    D. L. Bartel
    Medical and Biological Engineering and Computing, 2002, 40 : 641 - 646
  • [9] Periprosthetic modelling of femoral component fit using computed tomography data for total hip arthroplasty: a feasibility study
    Hauser-Kara, DA
    Bartel, DL
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (06) : 641 - 646
  • [10] Low Dose Computed Tomography for 3D Planning of Total Hip Arthroplasty: Evaluation of Radiation Exposure and Image Quality
    Huppertz, Alexander
    Lembcke, Alexander
    Sariali, El-hadi
    Durmus, Tahir
    Schwenke, Carsten
    Hamm, Bernd
    Sparmann, Martin
    Baur, Alexander D. J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 649 - 656