A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media

被引:104
|
作者
Tillikainen, L. [1 ]
Helminen, H. [1 ]
Torsti, T. [1 ]
Siljamaki, S. [1 ]
Alakuijala, J. [1 ]
Pyyry, J. [1 ]
Ulmer, W. [2 ]
机构
[1] Varian Med Syst Finland Oy, FIN-00270 Helsinki, Finland
[2] Varian Med Syst Imaging Lab GmbH, CH-5408 Baden, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 14期
关键词
D O I
10.1088/0031-9155/53/14/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In thiswork, a novel three-dimensional superposition algorithm for photon dose calculation is presented. The dose calculation is performed as a superposition of pencil beams, which are modified based on tissue electron densities. The pencil beams have been derived from Monte Carlo simulations, and are separated into lateral and depth-directed components. The lateral component is modeled using exponential functions, which allows accurate modeling of lateral scatter in heterogeneous tissues. The depth-directed component represents the total energy deposited on each plane, which is spread out using the lateral scatter functions. Finally, convolution in the depth direction is applied to account for tissue interface effects. The method can be used with the previously introduced multiple-source model for clinical settings. The method was compared against Monte Carlo simulations in several phantoms including lung-and bone-type heterogeneities. Comparisons were made for several field sizes for 6 and 18 MV energies. The deviations were generally within (2%, 2 mm) of the field central axis dmax. Significantly larger deviations (up to 8%) were found only for the smallest field in the lung slab phantom for 18MV. The presented method was found to be accurate in a wide range of conditions making it suitable for clinical planning purposes.
引用
收藏
页码:3821 / 3839
页数:19
相关论文
共 50 条
  • [21] VERIFICATION OF PHOTON DOSE CALCULATION ACCURACY BY THE PENCIL BEAM AND ANALYTICAL ANISOTROPIC ALGORITHM USING MOSFET DETECTORS
    Swinnen, A.
    Nulens, A.
    Verstraete, J.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S414 - S414
  • [22] A GPU-based finite-size pencil beam algorithm with 3D-density correction for radiotherapy dose calculation
    Gu, Xuejun
    Jelen, Urszula
    Li, Jinsheng
    Jia, Xun
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (11): : 3337 - 3350
  • [23] Evaluation of a Proton Pencil Beam Alogirithm for Dose Calculations in Heterogeneous Media
    Knutson, N.
    Chapman, J.
    Fontenot, J.
    Newhauser, W.
    Hogstrom, K.
    MEDICAL PHYSICS, 2012, 39 (06) : 4020 - 4020
  • [24] Experimental pencil beam kernels derivation for 3D dose calculation in flattening filter free modulated fields
    Azcona, Juan Diego
    Barbes, Benigno
    Wang, Lilie
    Burguete, Javier
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : 50 - 66
  • [25] Clinical Implementation of a GPU Accelerated Pencil Beam Dose Calculation Algorithm
    Chen, H.
    Xiao, Z.
    Du, D.
    Yang, D.
    Mutic, S.
    Li, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3823 - 3823
  • [26] A GPU-Based Finite-Size Pencil Beam (FSPB) Algorithm with 3D-Density Correction for Radiotherapy Dose Calculation
    Gu, X.
    Jelen, U.
    Li, J.
    Jia, X.
    Jiang, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [27] Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy
    Egashira, Y.
    Nishio, T.
    Hotta, K.
    Kohno, R.
    Uesaka, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04): : 1169 - 1184
  • [28] EXPERIMENTAL EVALUATION OF A 2D AND 3D ELECTRON PENCIL BEAM ALGORITHM
    MAH, E
    ANTOLAK, J
    SCRIMGER, JW
    BATTISTA, JJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (09): : 1179 - 1194
  • [29] Development of a 3-D convolution/superposition algorithm for precise dose calculation in the skull
    Mack A.
    Weltz D.
    Scheib S.G.
    Wowra B.
    Böttcher H.
    Seifer V.
    Australasian Physics & Engineering Sciences in Medicine, 2006, 29 (1): : 1 - 12
  • [30] Delta-Functional Multi Segmented Pencil Beam Algorithm for Highly Accurate Proton Dose Calculation in Heterogeneous Body
    Egashira, Y.
    Nishio, T.
    Kameoka, S.
    Matsuura, T.
    Uesaka, M.
    MEDICAL PHYSICS, 2010, 37 (06)