Repeatable and reproducible measurements of myocardial oxidative metabolism, blood flow and external efficiency using 11C-acetate PET

被引:11
|
作者
Wu, Kai Yi [1 ]
Dinculescu, Vincent [1 ]
Renaud, Jennifer M. [1 ]
Chen, Shin-Yee [1 ]
Burwash, Ian G. [1 ]
Mielniczuk, Lisa M. [1 ]
Beanlands, Rob S. B. [1 ]
deKemp, Robert A. [1 ]
机构
[1] Univ Ottawa, Div Cardiol, Heart Inst, 40 Ruskin St, Ottawa, ON K1Y4W7, Canada
基金
加拿大健康研究院;
关键词
C-11-acetate; PET; Reproducibility; Repeatability; Test-retest; POSITRON-EMISSION-TOMOGRAPHY; POSITIVE AIRWAY PRESSURE; OXYGEN-CONSUMPTION; HEART-FAILURE; ENERGETICS; PERFUSION; TRACER;
D O I
10.1007/s12350-018-1206-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundNon-invasive approaches to investigate myocardial efficiency can help track the progression of heart failure (HF). This study evaluates the repeatability and reproducibility of C-11-acetate positron emission tomography (PET) imaging of oxidative metabolism.Methods and resultsDynamic C-11-acetate PET scans were performed at baseline and followup (4722days apart) in 20 patients with stable HF with reduced ejection fraction. Two observers blinded to patients' clinical data used FlowQuant((R)) to evaluate test-retest repeatability, as well as intra- and inter-observer reproducibility of C-11-acetate tracer uptake and clearance rates, for the measurement of myocardial oxygen consumption (MVO2), myocardial external efficiency (MEE), work metabolic index (WMI), and myocardial blood flow. Reproducibility and repeatability were evaluated using intra-class-correlation (ICC) and Bland-Altman coefficient-of-repeatability (CR). Test-retest correlations and repeatability were better for MEE and WMI compared to MVO2. All intra- and inter-observer correlations were excellent (ICC=0.95-0.99) and the reproducibility values (CR=3%-6%) were significantly lower than the test-retest repeatability values (22%-54%, P<0.001). Repeatability was improved for all parameters using a newer PET-computed tomography (CT) scanner compared to older PET-only instrumentation.Conclusion(11)C-acetate PET measurements of WMI and MEE exhibited excellent test-retest repeatability and operator reproducibility. Newer PET-CT scanners may be preferred for longitudinal tracking of cardiac efficiency.
引用
收藏
页码:1912 / 1925
页数:14
相关论文
共 50 条
  • [41] Methodologic aspects of myocardial blood flow quantification with 1-11C-acetate PET
    van den Hoff, J
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (09) : 1438 - 1438
  • [42] Myocardial oxidative metabolism is increased due to haemodynamic overload in patients with aortic valve stenosis: assessment using 11C-acetate positron emission tomography
    Masanao Naya
    Satoru Chiba
    Hiroyuki Iwano
    Satoshi Yamada
    Chietsugu Katoh
    Osamu Manabe
    Keiichiro Yoshinaga
    Yoshiro Matsui
    Nagara Tamaki
    Hiroyuki Tsutsui
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 2242 - 2248
  • [43] Myocardial oxidative metabolism is increased due to haemodynamic overload in patients with aortic valve stenosis: assessment using 11C-acetate positron emission tomography
    Naya, Masanao
    Chiba, Satoru
    Iwano, Hiroyuki
    Yamada, Satoshi
    Katoh, Chietsugu
    Manabe, Osamu
    Yoshinaga, Keiichiro
    Matsui, Yoshiro
    Tamaki, Nagara
    Tsutsui, Hiroyuki
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (12) : 2242 - 2248
  • [44] Validation of 11C-acetate tracer kinetic models for the assessment of myocardial blood flow in normal adults and in patients with hypertrophic cardiomyopathy
    Timmer, S. A. J.
    Lubberink, M.
    Germans, T.
    Gotte, M. J. W.
    Ten Berg, J. M.
    ten Cate, F. J.
    van Rossum, A. C.
    Lammertsma, A.
    Knaapen, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S249 - S249
  • [45] Evaluation of myocardial oxidative metabolism in mice with carbon-11 acetate and dynamic PET
    Tsui, Benjamin
    Lee, Taek-Soo
    Marx-Rattner, Ruth
    Sysa-Shah, Polina
    Abadir, Peter
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [46] Methodologic aspects of myocardial blood flow quantification with 1-11C-acetate PET -: Reply
    Sciacca, RR
    Bergmann, SR
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (09) : 1439 - 1439
  • [47] Normal variability and test-retest reproducibility of myocardial blood flow measurements in mice using C-11 acetate and small animal PET imaging
    Lamoureux, Marc
    Kordos, Myra
    Klein, Ran
    Renaud, Jennifer
    Mason, Samantha
    Beanlands, Rob
    DaSilva, Jean
    Dekemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [48] Automatic extraction of forward stroke volume using dynamic 11C-acetate PET/CT
    Harms, Hendrik
    Tolbod, Lars
    Hansson, Nils
    Kim, Won
    Wiggers, Henrik
    Frokiaer, Jorgen
    Sorensen, Jens
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [49] Validation of 11C-acetate tracer kinetic models for the assessment of myocardial blood flow in normal adults and in patients with hypertrophic cardiomyopathy.
    Timmer, S. A. J.
    Lubberink, M.
    Germans, T.
    Gotte, M. J. W.
    Ten Berg, J. M.
    ten Cate, F. J.
    van Rossum, A. C.
    Lammertsma, A.
    Knaapen, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (SUPPL 2) : 249 - 249
  • [50] MYOCARDIAL OXIDATIVE-METABOLISM IN HYPERTHYROID PATIENTS ASSESSED BY PET WITH CARBON-11-ACETATE
    TORIZUKA, T
    TAMAKI, N
    KASAGI, K
    MISAKI, T
    KAWAMOTO, M
    TADAMURA, E
    MAGATA, Y
    YONEKURA, Y
    MORI, T
    KONISHI, J
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (11) : 1981 - 1986