Repeatable and reproducible measurements of myocardial oxidative metabolism, blood flow and external efficiency using 11C-acetate PET

被引:11
|
作者
Wu, Kai Yi [1 ]
Dinculescu, Vincent [1 ]
Renaud, Jennifer M. [1 ]
Chen, Shin-Yee [1 ]
Burwash, Ian G. [1 ]
Mielniczuk, Lisa M. [1 ]
Beanlands, Rob S. B. [1 ]
deKemp, Robert A. [1 ]
机构
[1] Univ Ottawa, Div Cardiol, Heart Inst, 40 Ruskin St, Ottawa, ON K1Y4W7, Canada
基金
加拿大健康研究院;
关键词
C-11-acetate; PET; Reproducibility; Repeatability; Test-retest; POSITRON-EMISSION-TOMOGRAPHY; POSITIVE AIRWAY PRESSURE; OXYGEN-CONSUMPTION; HEART-FAILURE; ENERGETICS; PERFUSION; TRACER;
D O I
10.1007/s12350-018-1206-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundNon-invasive approaches to investigate myocardial efficiency can help track the progression of heart failure (HF). This study evaluates the repeatability and reproducibility of C-11-acetate positron emission tomography (PET) imaging of oxidative metabolism.Methods and resultsDynamic C-11-acetate PET scans were performed at baseline and followup (4722days apart) in 20 patients with stable HF with reduced ejection fraction. Two observers blinded to patients' clinical data used FlowQuant((R)) to evaluate test-retest repeatability, as well as intra- and inter-observer reproducibility of C-11-acetate tracer uptake and clearance rates, for the measurement of myocardial oxygen consumption (MVO2), myocardial external efficiency (MEE), work metabolic index (WMI), and myocardial blood flow. Reproducibility and repeatability were evaluated using intra-class-correlation (ICC) and Bland-Altman coefficient-of-repeatability (CR). Test-retest correlations and repeatability were better for MEE and WMI compared to MVO2. All intra- and inter-observer correlations were excellent (ICC=0.95-0.99) and the reproducibility values (CR=3%-6%) were significantly lower than the test-retest repeatability values (22%-54%, P<0.001). Repeatability was improved for all parameters using a newer PET-computed tomography (CT) scanner compared to older PET-only instrumentation.Conclusion(11)C-acetate PET measurements of WMI and MEE exhibited excellent test-retest repeatability and operator reproducibility. Newer PET-CT scanners may be preferred for longitudinal tracking of cardiac efficiency.
引用
收藏
页码:1912 / 1925
页数:14
相关论文
共 50 条
  • [31] Myocardial Infarction With Nonobstructive Coronary Arteries Assessed by 11C-Acetate Cardiac PET
    Cho, Sang-Geon
    Kim, Yongcheol
    Jeong, Myung Ho
    Bom, Hee-Seung
    CLINICAL NUCLEAR MEDICINE, 2019, 44 (03) : e166 - e167
  • [32] Improved spillover correction model to quantify myocardial blood flow by 11C-acetate PET: comparison with 15O-H2O PET
    Mori, Yuki
    Manabe, Osamu
    Naya, Masanao
    Tomiyama, Yuuki
    Yoshinaga, Keiichiro
    Magota, Keiichi
    Oyama-Manabe, Noriko
    Hirata, Kenji
    Tsutsui, Hiroyuki
    Tamaki, Nagara
    Katoh, Chietsugu
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (01) : 15 - 20
  • [33] Appropriate parameters of the ordered-subset expectation maximization algorithm on measurement of myocardial blood flow and oxygen consumption with 11C-acetate PET
    Kobayashi, Masato
    Mori, Tetsuya
    Kiyono, Yasushi
    Tsujikawa, Tetsuya
    Maruyama, Rikiya
    Higaki, Yusuke
    Shikano, Naoto
    Nishii, Ryuichi
    Kawai, Keiichi
    Kudo, Takashi
    Okazawa, Hidehiko
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (02) : 130 - 138
  • [34] Myocardial tissue and metabolism characterization in men with alcohol consumption by cardiovascular magnetic resonance and 11C-acetate PET/CT
    Shuai Liu
    Xue Lin
    Ximin Shi
    Ligang Fang
    Li Huo
    Fei Shang
    Juhani Knuuti
    Chunlei Han
    Xiaomeng Wu
    Rui Guo
    Haiyan Ding
    Runhua Zhang
    Huimin Duan
    Jie Ding
    Haiqun Xing
    Xihai Zhao
    Journal of Cardiovascular Magnetic Resonance, 22
  • [35] Heterogeneous reduction of myocardial oxidative metabolism in patients with ischemic and dilated cardiomyopathy using C-11 acetate PET
    Wu, Yen-Wen
    Naya, Masanao
    Tsukamoto, Takahiro
    Komatsu, Hiroshi
    Morita, Koichi
    Yoshinaga, Keiichiro
    Kuge, Yuji
    Tsutsui, Hiroyuki
    Tamaki, Nagara
    CIRCULATION JOURNAL, 2008, 72 (05) : 786 - 792
  • [36] EVALUATION OF RENAL TUMOUR USING 11C-ACETATE AND FDG PET IMAGING
    Oyama, N.
    Takahara, N.
    Hasegawa, U.
    Miwa, Y.
    Akino, H.
    Okazawa, H.
    Fujibayashi, Y.
    INTERNAL MEDICINE JOURNAL, 2011, 41 : 12 - 13
  • [37] PET/CT acquisition protocol using 11C-acetate for prostate cancer
    Em, Sotheary
    Reynold, Roger
    Morgan, Mary
    Epley, William
    Richard, Wahl
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [38] Astrocytic energy metabolism in rats after cerebral ischemia: 11C-acetate PET study
    Matsunaga, K.
    Watabe, T.
    Kanai, Y.
    Horitsugi, G.
    Ikeda, H.
    Kato, H.
    Naka, S.
    Isohashi, K.
    Shimosegawa, E.
    Hatazawa, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S616 - S616
  • [39] Radiosynthesis of [11C]acetate for PET imaging of myocardial oxidative metabolism in patients with dilated cardiomyopathy
    Jiang, Huailei
    Mangner, Tom
    Bronstein, Joel
    Muzik, Otto
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [40] Noninvasive quantification of the differential portal and arterial contribution to the liver blood supply from PET measurements using the 11C-acetate kinetic model
    Chen, SR
    Feng, DG
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (09) : 1579 - 1585