Detection of Mycoplasma pneumoniae, Chlamydia pneumoniae, and Legionella spp. in clinical specimens using a single-tube multiplex real-time PCR assay

被引:77
|
作者
Thurman, Kathleen A. [1 ]
Warner, Agnes K. [1 ]
Cowart, Kelley C. [1 ]
Benitez, Alvaro J. [1 ]
Winchell, Jonas M. [1 ]
机构
[1] Ctr Dis Control & Prevent, Resp Dis Branch, Atlanta, GA 30333 USA
关键词
Real-time PCR; Multiplex real-time PCR; Community-acquired pneumonia; COMMUNITY-ACQUIRED PNEUMONIA; CHAIN-REACTION ASSAY; CHLAMYDOPHILA-PNEUMONIAE; RESPIRATORY SPECIMENS; DIAGNOSIS; PNEUMOPHILA; INFECTION; DISEASE; ADULTS; PREVENTION;
D O I
10.1016/j.diagmicrobio.2010.11.014
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
A multiplex real-time PCR assay for the detection of Mycoplasma pneumoniae (MP181), Chlamydia (Chlamydophila) pneumoniae (CP-Arg), Legionella spp. (Pan-Leg), and the human RNase P (RNase P) gene was developed for rapid testing of atypical bacterial respiratory pathogens in clinical specimens. This method uses 4 distinct hydrolysis probes to detect 3 leading causes of community-acquired pneumonia. The assay was evaluated for specificity and sensitivity by testing against 35 related organisms, a dilution series of each specific target and 197 clinical specimens. Specificity testing demonstrated no cross-reactivity. A comparison to previously validated singleplex real-time PCR assays for each agent was also performed. The analytical sensitivity for specific pathogen targets in both the singleplex and multiplex was identical (50 fg), while efficiencies ranged from 82% to 97% for the singleplex assays and from 90% to 100% for the multiplex assay. The clinical sensitivity of the multiplex assay was improved for the Pan-Leg and CP-Arg targets when compared to the singleplex. The MP181 assay displayed equivalent performance. This multiplex assay provides an overall improvement in the diagnostic capability for these agents by demonstrating a sensitive, high-throughput and rapid method. This procedure may allow for a practical and efficient means to test respiratory clinical specimens for atypical pneumonia agents in health care settings and facilitate an appropriate public health response to outbreaks. Published by Elsevier Inc.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] A Single-Tube Real-Time PCR Assay for Mycoplasma Detection as a Routine Quality Control of Cell Therapeutics
    Janetzko, Karin
    Rink, Gabi
    Hecker, Andrea
    Bieback, Karen
    Klueter, Harald
    Bugert, Peter
    [J]. TRANSFUSION MEDICINE AND HEMOTHERAPY, 2014, 41 (01) : 83 - 89
  • [22] Multiplex Real-time PCR Assay for the Detection of all Chlamydia Species and Simultaneous Differentiation of C. psittaci and C. pneumoniae in Human Clinical Specimens
    Wolff, Bernard J.
    Gaines, Anna
    Conley, Andrew B.
    Norris, Emily
    Rishishwar, Lavanya
    Chande, Aroon T.
    Yang, Eungi
    Diaz, Maureen H.
    Winchell, Jonas M.
    [J]. ANNALS OF LABORATORY MEDICINE, 2023, 43 (04) : 375 - 380
  • [23] Evaluation of a Single-Tube Multiplex Real-Time PCR for Differentiation of Members of the Mycobacterium tuberculosis Complex in Clinical Specimens
    Halse, Tanya A.
    Escuyer, Vincent E.
    Musser, Kimberlee A.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (07) : 2562 - 2567
  • [24] The ProPneumo-1™ assay:: Detection of chlamydophila pneumoniae, mycoplasma pneumoniae, and an internal control using multiplex PCR on multiple real time PCR systems.
    Dollhopf, S
    Majewski, W
    Douglass, P
    Khanna, M
    Visuri, S
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2005, 7 (05): : 674 - 674
  • [25] Development of real-time PCR assay for simultaneous detection of Mycoplasma pneumoniae and Chlamydia pneumonia on ExiPrep™16 and Exicycler™96 system
    Kim, S.
    Kim, B.
    Byun, S.
    Park, H.
    [J]. CLINICAL CHEMISTRY, 2009, 55 (06) : A146 - A147
  • [26] Development and evaluation of Chlamylege, a new commercial test allowing simultaneous detection and identification of Legionella, Chlamydophila pneumoniae, and Mycoplasma pneumoniae in clinical respiratory specimens by multiplex PCR
    Ginevra, C
    Barranger, C
    Ros, A
    Mory, O
    Stephan, JL
    Freymuth, F
    Joannès, M
    Pozzetto, B
    Grattard, F
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (07) : 3247 - 3254
  • [27] Development of multiplex real-time PCR assay for the detection of Brucella spp., Leptospira spp. and Campylobacter foetus
    Selim, Abdelfattah M.
    Elhaig, Mahmoud M.
    Gaede, Wolfgang
    [J]. VETERINARIA ITALIANA, 2014, 50 (04) : 269 - 275
  • [28] Quantitative detection of respiratory Chlamydia pneumoniae infection by real-time PCR
    Kuoppa, Y
    Boman, J
    Scott, L
    Kumlin, U
    Eriksson, I
    Allard, A
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (06) : 2273 - 2274
  • [29] Evaluation of Five Real-Time PCR Assays for Detection of Mycoplasma pneumoniae
    Dumke, Roger
    Jacobs, Enno
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (11) : 4078 - 4081
  • [30] Single-tube multiplex real-time PCR assay for rapid and reliable detection of HLA-A*31:01 allele
    Zhang, Tingting
    Xiao, Ying
    Wang, Yanxia
    Li, Yanwei
    Zhang, Lirong
    Chen, Chao
    Wang, Huijuan
    [J]. PHARMACOGENOMICS, 2018, 19 (10) : 837 - 846