Single-tube multiplex real-time PCR assay for rapid and reliable detection of HLA-A*31:01 allele

被引:3
|
作者
Zhang, Tingting [1 ,2 ]
Xiao, Ying [1 ,2 ]
Wang, Yanxia [1 ,2 ]
Li, Yanwei [1 ,2 ]
Zhang, Lirong [1 ]
Chen, Chao [1 ,2 ]
Wang, Huijuan [1 ,2 ]
机构
[1] Northwest Univ, Sch Life Sci, Xian 710069, Shaanxi, Peoples R China
[2] Natl Engn Res Ctr Miniaturized Detect Syst, Xian 710069, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
carbamazepine; HLA-A*31:01; hypersensitivity reactions; ADVERSE DRUG-REACTIONS; ANTIEPILEPTIC DRUGS; CARBAMAZEPINE; HYPERSENSITIVITY; RISK; DNA; HLA-B-ASTERISK-15/02; EPILEPSY;
D O I
10.2217/pgs-2018-0050
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: HLA-A*31:01 has been associated with carbamazepine-induced hypersensitivity reactions. HLA-A*31:01 genetic testing is recommended before the initiation of carbamazepine therapy. Methods: A novel real-time PCR assay was designed for HLA-A*31:01 detection by allele-specific primers and TaqMan minor groove binding probes. Results: The genotyping results in 100 subjects by the established method who were in 100% agreement with the sequencing-based typing method. The assay presents a sensitivity of 1 (95% CI:0.69-1.00), a specificity of 1 (95% CI:0.96-1.00) and a positive and negative predictive value of 1. The carrier rates of HLA-A*31:01 in Tibetan (n = 45), Han Chinese (n = 100), Miaos (n = 48) and Khalkhas (n = 48) were 22.2, 10, 4.2 and 18.8%, respectively. Conclusion: This assay is reliable to detect HLA-A*31:01 and would be useful to prevent carbamazepine-induced hypersensitivity reactions.
引用
收藏
页码:837 / 846
页数:10
相关论文
共 50 条
  • [1] Development of a rapid and reliable single-tube multiplex real-time PCR method for HLA-A*24:02 genotyping
    Wang, Yanxia
    Zhang, Tingting
    Zhang, Lirong
    Pei, Yanrui
    Zhao, Lili
    Li, Yanwei
    Liu, Lin
    Wang, Huijuan
    [J]. PHARMACOGENOMICS, 2019, 20 (11) : 803 - 812
  • [2] Rapid and reliable genotyping of HLA-B*58:01 in four Chinese populations using a single-tube duplex real-time PCR assay
    Kang, Xing
    Chen, Rong
    Han, Min
    Liu, Zhengbin
    Liu, Jinhui
    Dai, Penggao
    Chen, Chao
    Wang, Huijuan
    [J]. PHARMACOGENOMICS, 2016, 17 (01) : 47 - 57
  • [3] Rapid and reliable screening of HLA-B*15:02 in four Chinese populations using single-tube multiplex real-time PCR assay
    Wang, Huijuan
    Kang, Xing
    Zhou, Shaohe
    Chen, Rong
    Liu, Zhengbin
    Han, Min
    Chen, Chao
    Gong, Yongkuan
    [J]. PHARMACOGENOMICS, 2017, 18 (09) : 853 - 863
  • [4] Detection of HLA-A*3101 by Real-Time PCR Assay
    Avula, R.
    Black, J. L.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 843 - 843
  • [5] A Rapid Single-Tube Protocol for HAV Detection by Nested Real-Time PCR
    Yuan Hu
    Ivica Arsov
    [J]. Food and Environmental Virology, 2014, 6 : 189 - 195
  • [6] A Rapid Single-Tube Protocol for HAV Detection by Nested Real-Time PCR
    Hu, Yuan
    Arsov, Ivica
    [J]. FOOD AND ENVIRONMENTAL VIROLOGY, 2014, 6 (03) : 189 - 195
  • [7] Simultaneous and rapid detection method for measles and rubella using single-tube multiplex real-time quantitative RT-PCR
    Yoshioka, Nori
    Hagiya, Hideharu
    Deguchi, Matsuo
    Hamaguchi, Shigeto
    Kagita, Masanori
    Tomono, Kazunori
    [J]. JOURNAL OF INFECTION AND CHEMOTHERAPY, 2019, 25 (10) : 829 - 831
  • [8] Rapid and Reliable Genotyping of HLA-B*57:01 in Four Chinese Populations Using a Single-Tube Duplex Real-Time Polymerase Chain Reaction Assay
    Han, Min
    Kang, Xing
    Liu, Zhengbin
    Zhang, Tingting
    Li, Yanwei
    Chen, Chao
    Wang, Huijuan
    [J]. AIDS RESEARCH AND HUMAN RETROVIRUSES, 2017, 33 (07) : 711 - 717
  • [9] Improving the specific diagnosis of trematode, cestode and nematode infections by a multiplex single-tube real-time PCR assay
    Wong, Samson S. Y.
    Poon, Rosana W. S.
    To, Kelvin K. W.
    Chan, Jasper F. W.
    Lu, Gang
    Xing, Fanfan
    Cheng, Vincent C. C.
    Yuen, Kwok-Yung
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2019, 72 (07) : 487 - 492
  • [10] A SINGLE-TUBE REAL-TIME PCR ASSAY FOR MYCOPLASMA DETECTION AS A ROUTINE QUALITY CONTROL OF CELL THERAPEUTICS
    Janetzko, K.
    Rink, G.
    Hecker, A.
    Bieback, K.
    Klueter, H.
    Bugert, P.
    [J]. CYTOTHERAPY, 2014, 16 (04) : S45 - S45