Evaluation of patient-specific scatter-corrected digital chest tomosynthesis

被引:0
|
作者
Inscoe, Christina R. [1 ]
Puett, Connor [2 ,3 ,4 ]
Billingsley, Alex J. [2 ,3 ]
Zhou, Otto [1 ]
Lu, Jianping [1 ]
Lee, Yueh Z. [4 ]
机构
[1] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Joint Dept Biomed Engn, Chapel Hill, NC 27599 USA
[3] North Carolina State Univ, Raleigh, NC 27607 USA
[4] Univ N Carolina, Sch Med, Chapel Hill, NC 27514 USA
关键词
XIM (X-ray imaging); TSY; (Tomosynthesis; DIAG (Diagnostic imaging);
D O I
10.1117/12.2549316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: Chest tomosynthesis is an attractive alternative to computed tomography (CT) for lung nodule screening, but reductions in image quality caused by radiation scatter remains an important limitation. Conventional anti-scatter grids result in higher patient dose, and alternative approaches are needed. The purpose of this study was to validate a low-dose patient-specific approach to scatter correction for an upcoming human imaging study. Method: A primary sampling device (PSD) was designed and scatter correction algorithm incorporated into an experimental stationary digital chest tomosynthesis (s-DCT) system for this study to directly compute scatter from the primary beam information. Phantom and an in-vivo porcine subject were imaged. Total scan time was measured and image quality evaluated. Results: Comparison of reconstruction slice images from uncorrected and scatter-corrected projection images reveals improved image quality, with increased feature conspicuity. Each scan in the current setup required twelve seconds, in addition to one second for PSD retraction, for a total scan time of 25 seconds. Conclusions: We have evaluated the prototype low-dose, patient-specific scatter correction methodology using phantom studies in preparation for a clinical trial. Incorporating only 5% of additional patient dose, the reconstruction slices exhibit increased visual conspicuity of anatomical features, with the primary drawback of increased total scan time. Though used for tomosynthesis, the technique can be easily translated to digital radiography in lieu of an anti-scattering grid.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Evaluation of patient dose during a digital breast tomosynthesis
    Shakya, S.
    Sulwathura, U.
    Wickramanayake, M.
    Dulshara, T.
    Herath, L. H. M. I. M.
    Wickramasinghe, W. M. I. S.
    Senanayake, G.
    [J]. RADIOGRAPHY, 2023, 29 (03) : 573 - 576
  • [22] In vitro digital subtraction angiographic evaluation of flow diverters in a patient-specific aneurysm
    Jou, Liang-Der
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2017, 23 (03) : 260 - 266
  • [23] Deep learning reconstruction of digital breast tomosynthesis images for accurate breast density and patient-specific radiation dose estimation
    Teuwen, Jonas
    Moriakov, Nikita
    Fedon, Christian
    Caballo, Marco
    Reiser, Ingrid
    Bakic, Pedrag
    Garcia, Eloy
    Diaz, Oliver
    Michielsen, Koen
    Sechopoulos, Ioannis
    [J]. MEDICAL IMAGE ANALYSIS, 2021, 71 (71)
  • [24] Quantitative evaluation of anatomical noise in chest digital tomosynthesis, digital radiography, and computed tomography
    Lee, D.
    Choi, S.
    Lee, H.
    Kim, D.
    Choi, S.
    Kim, H. -J.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [25] Evaluation of low contrast detectability after scatter correction in digital breast tomosynthesis.
    Michielsen, Koen
    Fieselmann, Andreas
    Cockmartin, Lesley
    Nuyts, Johan
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [26] Use of patient-specific estimates in patient evaluation and rehabilitation
    Stephens, D
    Jaworski, A
    Kerr, P
    Zhao, F
    [J]. SCANDINAVIAN AUDIOLOGY, 1998, 27 : 61 - 68
  • [27] Development and preclinical evaluation of a patient-specific high energy x-ray phase sensitive breast tomosynthesis system
    Ghani, Muhammad U.
    Wu, Xizeng
    Fajardo, Laurie L.
    Jing, Zhengxue
    Wong, Molly D.
    Zheng, Bin
    Omoumi, Farid
    Li, Yuhua
    Yan, Aimin
    Jenkins, Peter
    Hillis, Stephen L.
    Linstroth, Laura
    Liu, Hong
    [J]. MEDICAL PHYSICS, 2021, 48 (05) : 2511 - 2520
  • [28] Evaluation of the accuracy of a patient-specific instrumentation by navigation
    Fabio Conteduca
    Raffaele Iorio
    Daniele Mazza
    Ludovico Caperna
    Gabriele Bolle
    Giuseppe Argento
    Andrea Ferretti
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2194 - 2199
  • [29] Evaluation of the accuracy of a patient-specific instrumentation by navigation
    Conteduca, Fabio
    Iorio, Raffaele
    Mazza, Daniele
    Caperna, Ludovico
    Bolle, Gabriele
    Argento, Giuseppe
    Ferretti, Andrea
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2194 - 2199
  • [30] Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis
    Susan D. Kost
    Nicholas D. Fraser
    Diana E. Carver
    David R. Pickens
    Ronald R. Price
    Marta Hernanz-Schulman
    Michael G. Stabin
    [J]. Pediatric Radiology, 2015, 45 : 1771 - 1780