Optical quality of the eye degraded by time-varying wavefront aberrations with tear film dynamics

被引:15
|
作者
Hirohara, Yoko
Mihashi, Toshifumi
Koh, Shizuka
Ninomiya, Sayuri
Maeda, Naoyuki
Fujikado, Takashi
机构
[1] Osaka Univ, Grad Sch Med, Dept Appl Visual Sci, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Ophthalmol, Osaka, Japan
[3] Topcon Corp, Res Inst, Tokyo, Japan
关键词
aberration; retinal image; Shack-Hartmann aberrometer; Strehl ratio; tear film;
D O I
10.1007/s10384-007-0440-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Wavefront aberrations (WFAs) of the eye vary with time because of the tear film dynamics. We investigated, using a simulation method, the variation of optical quality with time-varying wavefront measurements of 13 eyes with different refractions. Methods: WFAs of 13 normal eyes of 13 subjects were measured every second for 10s. First, we simulated WFAs with conventional corneal laser refractive surgery by subtracting the second-order aberrations of the least aberrated measurement from measured consecutive WFAs. Second, we simulated customized refractive surgery by subtracting the second- to sixth-order aberrations of the least aberrated measurement from measured consecutive WFAs. We calculated Strehl ratios and retinal images from these corrected consecutive WFAs. Results: In one eye, the root mean square (RMS) values of WFAs with a second-order correction were sometimes smaller than those of WFAs with a second- to sixth-order correction, when these were compared at the same time point after a blink. However, in the other 12 eyes, the RMS values with second- to sixth-order corrections were smaller than those with only a second-order correction. In eight eyes, the Strehl ratios with second- to sixth-order corrections were larger than those with second-order corrections. In the remaining five eyes, Strehl ratios with second- to sixth-order corrections were sometimes smaller than those with second-order corrections. Conclusions: In a simulation, the correction of time-invariant higher order aberrations usually reduced RMS values, but it did not always result in higher Strehl ratios than those obtained with only second-order corrections.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [21] The synchronized dynamics of time-varying networks
    Ghosh, Dibakar
    Frasca, Mattia
    Rizzo, Alessandro
    Majhi, Soumen
    Rakshit, Sarbendu
    Alfaro-Bittner, Karin
    Boccaletti, Stefano
    PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 2022, 949 : 1 - 63
  • [22] DYNAMICS CONTROL BY A TIME-VARYING FEEDBACK
    Agrachev, A. A.
    Caponigro, M.
    JOURNAL OF DYNAMICAL AND CONTROL SYSTEMS, 2010, 16 (02) : 149 - 162
  • [23] Dynamics control by a time-varying feedback
    A. A. Agrachev
    M. Caponigro
    Journal of Dynamical and Control Systems, 2010, 16 : 149 - 162
  • [24] Time-varying grids for gas dynamics
    Coquel, F.
    Nguyen, Q. L.
    Postel, M.
    Tran, Q. H.
    PROGRESS IN INDUSTRIAL MATHEMATICS AT ECMI 2006, 2008, 12 : 887 - +
  • [25] Time-Varying Dynamics of the Norwegian Economy
    Akram, Q. Farooq
    Mumtaz, Haroon
    SCANDINAVIAN JOURNAL OF ECONOMICS, 2019, 121 (01): : 407 - 434
  • [26] Time-varying Investment Dynamics in the USA
    Mendieta-Munoz, Ivan
    ECONOMICS-THE OPEN ACCESS OPEN-ASSESSMENT E-JOURNAL, 2024, 18 (01):
  • [27] DYNAMICS OF TIME-VARYING THRESHOLD LEARNING
    SKLANSKY, J
    BERSHAD, NJ
    IEEE TRANSACTIONS ON INFORMATION THEORY, 1970, 16 (01) : 127 - +
  • [28] DYNAMICS OF TIME-VARYING THRESHOLD LEARNING
    SKLANSKY, J
    BERSHAD, NJ
    INFORMATION AND CONTROL, 1969, 15 (06): : 455 - &
  • [29] Real dynamic assessment of tear film optical quality for monitoring and early prevention of dry eye
    Wu, Ming-Feng
    Gao, Hui
    Zhao, Li-Jun
    Chen, Hua
    Huang, Yu-Kan
    MEDICINE, 2020, 99 (31)
  • [30] Automated Tear Film Surface Quality Breakup Time as a Novel Clinical Marker for Tear Hyperosmolarity in Dry Eye Disease
    Downie, Laura Elizabeth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (12) : 7260 - 7268