An MR Compatible LSO-PET Scanner for Molecular Imaging Studies

被引:0
|
作者
Mackewn, J. E. [1 ]
Keevil, S. F.
Hallett, W. A. [1 ,2 ]
Halsted, P. [1 ]
Page, R. A. [1 ]
Kelly, M.
Williams, S. C. R. [3 ]
Marsden, P. K. [1 ]
机构
[1] Kings Coll London, Guys Kings & St Thomas Sch Med, London, England
[2] GlaxoSmithKline, Translat Med & Technol, Greenford, Middx, England
[3] Kings Coll London, Inst Psychiat, London, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a detailed system description of an MR compatible PET scanner for small animal molecular imaging studies, which has recently been constructed. The system images a single slice and has an inner diameter 7.5cm. It consists of 4 concentric rings of 104 LSO crystals each with nominal dimensions of 2mm (tangential) by 3mm (axial) by 5mm (radial). The crystal ring is positioned at the centre of an MR scanner, and 3.5m long optical fibres transport the scintillation light to eight multi-channel PM tubes situated in a low field region in which they can function correctly. Position encoding boards convert the large number of signals from these multichannel photo-multiplier tubes to four position encoded signals. The electronics are standard NIM modules and can be housed in just two racks, to allow the system to be relocated easily for operation in a range of MR scanners. The signals are digitized on ADC cards in a PC and the raw data converted into a sinogram using an interpolation method prior to reconstruction. We present some preliminary results from the PET system. The system will now be fully evaluated and its performance assessed within the MR environment.
引用
收藏
页码:2986 / 2989
页数:4
相关论文
共 50 条
  • [21] The ClearPET™ neuro scanner:: A dedicated LSO/LuYAP phoswich small animal PET scanner
    Ziemons, K
    Achten, R
    Auffray, E
    Bauer, A
    Brandenburg, G
    Bruyndonckx, P
    Choi, Y
    Daemen, J
    Dehnhardt, M
    Devroede, O
    Fleischer, M
    Fuss, L
    Heinrichs, U
    Hollendung, A
    Holschbach, M
    Khodaverdi, M
    Kirchner, P
    Kleines, H
    Krieguer, M
    Larue, H
    Lecoq, P
    Leyendecker, M
    Moeller, R
    Morel, C
    Mosset, JB
    Parl, C
    Pietrzyk, U
    Schmitz, J
    Streun, M
    Tavernier, S
    Veggian, M
    Zimmermann, E
    Coenen, HH
    Halling, H
    Sievering, R
    Zilles, K
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2430 - 2433
  • [22] PET Performance Evaluation of a Pre-Clinical SiPM-Based MR-Compatible PET Scanner
    Mackewn, Jane E.
    Lerche, Christoph W.
    Weissler, Bjoern
    Sunassee, Kavitha
    de Rosales, Rafael T. M.
    Phinikaridou, Alkystis
    Salomon, Andre
    Ayres, Richard
    Tsoumpas, Charalampos
    Soultanidis, Georgios M.
    Gebhardt, Pierre
    Schaeffter, Tobias
    Marsden, Paul K.
    Schulz, Volkmar
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (03) : 784 - 790
  • [23] Performance Evaluation and Compatibility Studies of a Compact Preclinical Scanner for Simultaneous PET/MR Imaging at 7 Tesla
    Courteau, Alan
    McGrath, John
    Walker, Paul Michael
    Pegg, Rosie
    Martin, Gary
    Garipov, Ruslan
    Doughty, Peter
    Cochet, Alexandre
    Brunotte, Francois
    Vrigneaud, Jean-Marc
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (01) : 205 - 217
  • [24] Performance of a high sensitivity PET scanner based on LSO panel detectors
    Conti, M.
    Bendriem, B.
    Casey, M.
    Eriksson, L.
    Jakoby, B.
    Jones, W. F.
    Jones, J.
    Michel, C.
    Nahmias, C.
    Panin, V.
    Rappoport, V.
    Sibomana, M.
    Townsend, D. W.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1136 - 1142
  • [25] PET/MR: the Molecular Imaging Dream Team
    Maniawski, Piotr J.
    NUCLEAR MEDICINE REVIEW, 2011, 14 (01) : 47 - 50
  • [26] MOLECULAR IMAGING WITH PET-CT AND PET-MR
    Beuthien-Baumann, B.
    RADIOTHERAPY AND ONCOLOGY, 2012, 104 : 27 - 27
  • [27] A noninvasive LSO-APD blood radioactivity monitor for PET imaging studies
    Shokouhi, S
    Stoll, SP
    Villanueva, A
    Vaska, P
    Schlyer, DJ
    Woody, CL
    Yu, B
    O'Connor, P
    Pratte, JF
    Radeka, V
    Volkow, N
    Fowler, JS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1457 - 1461
  • [28] Molecular imaging in oncology: the acceptance of PET/CT and the emergence of MR/PET imaging
    Christiaan Schiepers
    Magnus Dahlbom
    European Radiology, 2011, 21 : 548 - 554
  • [29] Simultaneous PET/MR body imaging in rats: initial experiences with an integrated PET/MRI scanner
    Mitsuaki Tatsumi
    Seiichi Yamamoto
    Masao Imaizumi
    Tadashi Watabe
    Yasukazu Kanai
    Masaaki Aoki
    Hiroki Kato
    Eku Shimosegawa
    Jun Hatazawa
    Annals of Nuclear Medicine, 2012, 26 : 444 - 449
  • [30] Effect of temperature on the stability and performance of an LSO-APD PET scanner
    Spanoudalci, Virginia
    McElroy, David P.
    Zell, Karin
    Ziegler, Sibylle I.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 3014 - 3017