2D/3D registration of endoscopic ultrasound to CT volume data

被引:37
|
作者
Hummel, Johann [1 ]
Figl, Michael [1 ]
Bax, Michael
Bergmann, Helmar [1 ]
Birkfellner, Wolfgang [1 ]
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, Vienna, Austria
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 16期
关键词
D O I
10.1088/0031-9155/53/16/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a computer-aided navigation system using image fusion to support endoscopic interventions such as the accurate collection of biopsy specimens. An endoscope provides the physician with real- time ultrasound (US) and a video image. An image slice that corresponds to the corresponding image from the US scan head is derived from a preoperative computed tomography (CT) or magnetic resonance image volume data set using oblique reformatting and displayed side by side with the US image. The position of the image acquired by the US scan head is determined by a miniaturized electromagnetic tracking system (EMTS) after calibrating the endoscope's scan head. The transformation between the patient coordinate system and the preoperative data set is calculated using a 2D/3D registration. This is achieved by calibrating an intraoperative interventional CT slice with an optical tracking system (OTS) using the same algorithm as for the US calibration. The slice is then used for 2D/3D registration with the coordinate system of the preoperative volume. The fiducial registration error (FRE) for the US calibration was 2.0 mm +/- 0.4 mm; the interventional CT FRE was 0.36 +/- 0.12 mm; and the 2D/ 3D registration target registration error (TRE) was 1.8 +/- 0.3 mm. The point-to-point registration between the OTS and the EMTS had an FRE of 0.9 +/- 0.4 mm. Finally, we found an overall TRE for the complete system to be 3.9 +/- 0.6 mm.
引用
收藏
页码:4303 / 4316
页数:14
相关论文
共 50 条
  • [21] Intra-cardiac 2D US to 3D CT image registration
    Huang, Xishi
    Hill, Nicholas A.
    Ren, Jing
    Guiraudon, Gerard
    Peters, Terry M.
    [J]. MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [22] Volume registration tor 3D compounding of ultrasound images
    Kruecker, JF
    Meyer, CR
    LeCarpentier, GL
    Fowlkes, JB
    [J]. RADIOLOGY, 1999, 213P : 101 - 101
  • [23] Joint image registration and volume reconstruction for 3D ultrasound
    Sanches, JM
    Marques, JS
    [J]. PATTERN RECOGNITION LETTERS, 2003, 24 (4-5) : 791 - 800
  • [24] Sonographic measurement of thyroid gland volume: A comparison of 2D and 3D ultrasound
    Ying, Michael
    Sin, Man-hong
    Pang, Shuk-fan
    [J]. RADIOGRAPHY, 2005, 11 (04) : 242 - 248
  • [25] Registration of 2D cardiac images to real-time 3D ultrasound volumes for 3D stress echocardiography
    Leung, K. Y. Esther
    Van Stralen, Marijn
    Voormolen, Marco M.
    Van Burken, Gerard
    Nemes, Attila
    Ten Cate, Folkert J.
    Geleijnse, Marcel L.
    De Jong, Nico
    Van der Steen, Antonius F. W.
    Reiber, Johan H. C.
    Bosch, Johan G.
    [J]. MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [26] 3D Physics-Based Registration of 2D Dynamic MRI Data
    Trivisonne, Raffaella
    Peterlik, Igor
    Cotin, Stephane
    Courtecuisse, Hadrien
    [J]. MEDICINE MEETS VIRTUAL REALITY 22, 2016, 220 : 432 - 438
  • [27] THE COMPARISON OF 2D AND 3D DETECTORS FOR TLS DATA REGISTRATION - PRELIMINARY RESULTS
    Markiewicz, J. S.
    Markiewicz, L.
    Forys, P.
    [J]. 8TH INTERNATIONAL WORKSHOP 3D-ARCH: 3D VIRTUAL RECONSTRUCTION AND VISUALIZATION OF COMPLEX ARCHITECTURES, 2019, 42-2 (W9): : 467 - 472
  • [28] An Automatic Multimodal Data Registration Strategy for 2D/3D Information Fusion
    Schierl, Jonathan
    Asari, Vijayan
    Singer, Nina
    Aspiras, Theus
    Stokes, Andrew
    Keaffaber, Brett
    Van Rynbach, Andre
    Decker, Kevin
    Rabb, David
    [J]. MULTIMODAL IMAGE EXPLOITATION AND LEARNING 2022, 2022, 12100
  • [29] Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data
    van der Bom, M. J.
    Pluim, J. P. W.
    Gounis, M. J.
    de Kraats, E. B. van
    Sprinkhuizen, S. M.
    Timmer, J.
    Homan, R.
    Bartels, L. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04): : 1031 - 1043
  • [30] A fast and robust algorithm for 2D/3D panorama ultrasound data
    Scherzer, O
    Schoisswohl, A
    [J]. REAL-TIME IMAGING, 2002, 8 (01) : 53 - 60