Validation of NEMA NU4-2008 Scatter Fraction estimation with 18F and 68Ga for the ARGUS small-animal PET scanner

被引:0
|
作者
Vicente, E. [1 ,2 ]
Herraiz, J. L. [1 ]
Canadas, M. [3 ]
Cal-Gonzalez, J. [1 ]
Espana, S. [4 ,5 ]
Desco, M. [6 ,7 ,8 ]
Vaquero, J. J. [6 ]
Udias, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Dpto Fis Atom Mol & Nucl, Grp Fis Nucl, E-28040 Madrid, Spain
[2] CSIC, Inst Estruct Mat, Madrid, Spain
[3] CIEMAT Ctr Invest Energeticas Medioambientales &, Madrid, Spain
[4] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA USA
[5] Harvard Med Sch, Boston, MA USA
[6] Univ Carlos III Madrid, Dept Bioingn & Ingn Aeroesp, Madrid, Spain
[7] Univ Gregorio Maranon, Gen Hosp, Unidad Med & Cirugia Expt, Madrid, Spain
[8] Inst Salud Carlos III, CIBERSAM, Madrid, Spain
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The scatter fraction (SF) in PET data represents the fraction of coincidence events in which at least one of the two emitted photons have been scattered before being detected. It is usually estimated as the ratio of scattered events to total number of coincidences, when the number of random counts is negligible (less than 1% of true rates). SF provides a measurement of the relative sensitivity of the scanner to scattered radiation. It depends on object size, density and location inside the field of view, as well as on detector size, type of detector crystal and energy window. The performance evaluation guideline for small-animal PET NEMA (National Electrical Manufacturers Association) NU4-2008 proposes the estimation of the SF for three test phantoms made in proportion to the most widely used small animals in the laboratory: mouse, rat and monkey. The method estimates the different coincidence types in sinogram profiles from an off-centered line source inserted in these phantoms. We benchmark the procedure proposed by NEMA to estimate SF with F-18 and also with Ga-68, a radionuclide with lager positron range. Real data acquired with the ARGUS small-animal PET scanner (SEDECAL, Madrid, Spain) as well as simulations of the same scanner with peneloPET are used. The results show that, though SF should be practically the same with both F-18 and Ga-68 isotopes (and indeed our simulations indicate this) NEMA SF estimations with Ga-68 acquisitions are higher. This is due to the fact that Ga-68 positron range affects on the width of the line source profiles. Suggestions to modify the protocol to obtain similar SF estimations when using isotopes with larger positron range than F-18 are made.
引用
收藏
页码:3553 / 3557
页数:5
相关论文
共 41 条
  • [1] Performance Evaluation for 68Ga and 18F of the ARGUS Small-Animal PET Scanner Based on the NEMA NU-4 Standard
    Canadas, M.
    Romero Sanz, E.
    Oteo Vives, M.
    Vaquero, J. J.
    Desco, M.
    Vicente, E.
    Udias, J. M.
    Romero, L.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3454 - 3457
  • [2] Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards
    Sato, K.
    Shidahara, M.
    Watabe, H.
    Watanuki, S.
    Ishikawa, Y.
    Arakawa, Y.
    Nai, Y. H.
    Furumoto, S.
    Tashiro, M.
    Shoji, T.
    Yanai, K.
    Gonda, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 696 - 711
  • [3] 18F, 11C and 68Ga in small animal PET imaging
    Muellauer, J.
    Willimayer, R.
    Goertzen, A. L.
    Wanek, T.
    Langer, O.
    Birkfellner, W.
    Kuntner, C.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2013, 52 (06): : 250 - +
  • [4] Performance evaluation of a small-animal PET scanner with 213 mm axis using NEMA NU 4-2008
    Wei, Qing
    Wang, Yingjie
    Huang, Xianchao
    Li, Daowu
    Zheng, Yushuang
    Wang, Peilin
    Sun, Xiaoli
    Chai, Pei
    Han, Xiaorou
    Liu, Shuangquan
    Feng, Baotong
    Zhou, Wei
    Zeng, Xiangtao
    Zhu, Meiling
    Zhang, Zhiming
    Wei, Long
    MEDICAL PHYSICS, 2024,
  • [5] Image quality assessment for several positron emitters using the NEMA NU 4 2008 standards in the Inveon small-animal PET scanner
    Disselhorst, Jonathan
    Brom, Maarten
    Laverman, Peter
    Slump, Cornelis
    Boerman, Otto
    Oyen, Wim
    Gotthardt, Martin
    Visser, Eric
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [6] Performance Evaluation of a PEM Scanner Using the NEMA NU 4-2008 Small Animal PET Standards
    Luo, Weidong
    Anashkin, Edward
    Matthews, Christopher G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 94 - 103
  • [7] Image-Quality Assessment for Several Positron Emitters Using the NEMA NU 4-2008 Standards in the Siemens Inveon Small-Animal PET Scanner
    Disselhorst, Jonathan A.
    Brom, Maarten
    Laverman, Peter
    Slump, Cornelius H.
    Boerman, Otto C.
    Oyen, Wim J. G.
    Gotthardt, Martin
    Visser, Eric P.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (04) : 610 - 617
  • [8] Comparative performance measurement of 124I and 18F PET on Siemens Inveon PET using NEMA NU4-2008: Toward optimal parameters in 124I PET
    Yu, A. Ram
    Kim, Jin Su
    Kim, Kyeong Min
    Lee, Young Sub
    Kim, Jong Guk
    Park, JiAe
    Woo, Sang-Keun
    Kim, Hee-Joung
    Cheon, Gi Jeong
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [9] Technical Note: Performance evaluation of a small-animal PET/CT system based on NEMA NU 4-2008 standards
    Liu, Qiong
    Li, Chaofan
    Liu, Jiguo
    Krish, Kishore
    Fu, Xinlei
    Zhao, Jie
    Chen, Jyh-Cheng
    MEDICAL PHYSICS, 2021, 48 (09) : 5272 - 5282
  • [10] Investigation of the imaging characteristics of the ALBIRA II small animal PET system for 18F, 68Ga and 64Cu
    Attarwala, Ali Asgar
    Karanja, Yvonne Wanjiku
    Hardiansyah, Deni
    Romano, Chiara
    Roscher, Mareike
    Waengler, Bjoern
    Glatting, Gerhard
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (02): : 132 - 144