Design of a subcutaneous implantable biochip for monitoring of glucose and lactate

被引:84
|
作者
Guiseppi-Elie, A
Brahim, S
Slaughter, G
Ward, KR
机构
[1] Virginia Commonwealth Univ, Dept Emergency Med, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Dept Chem Engn, Richmond, VA 23284 USA
[3] Virginia Commonwealth Univ, Ctr Bioelect Biosensors & Biochips, Richmond, VA 23284 USA
关键词
amperometric; biochip; glucose; hydrogel; implantable; lactate; microdisc array; subcutaneous;
D O I
10.1109/JSEN.2005.846173
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design, fabrication, and in-vitro evaluation of an amperometric biochip that is designed for the continuous in vivo monitoring of physiological analytes is described. The 2 x 4 x 0.5 mm biochip contains two platinum working enzyme electrodes that adopt the microdise array design to minimize diffusional limitations associated with enzyme kinetics. This configuration permits either dual analyte sensing or a differential response analytical methodology during amperometric detection of a single analyte. The working enzyme electrodes are complemented by a large area platinized platinum counter electrode and a silver reference electrode. The biorecognition layer of the working electrodes was fabricated from around 1.0-mu m-thick composite membrane of principally tetraethylene glycol (TEGDA) cross-linked poly(2-hydroxyethyl methacrylate) that also contained a derivatized polypyrrole component and a biomimetic methacrylate component with pendant phosphorylcholine groups. These two additional components were introduced to provide interference screening and in vivo biocompatibility, respectively. This composite membrane was used to immobilize glucose oxidase and lactate oxidase onto both planar and microdisc array electrode designs, which were then used to assay for in vitro glucose and lactate, respectively. The glucose biosensor exhibited a dynamic linear range of 0.10-13.0 mM glucose with a response time (t(95)) of 50 s. The immobilized glucose oxidase within the hydrogel yielded a K-m(app) of 35 mM, not significantly different from that for the native, solution-borne enzyme (33 mM). The microdisc array biosensor displayed linearity for assayed lactate up to 90 mM, which represented a 30-fold increase in linear dynamic lactate range compared to the biosensor with the planar electrode configuration. Preliminary in vitro operational stability tests performed with the microdisc array lactate biosensor demonstrated retention of 80% initial biosensor response after five days of continuous operation in buffer under physiologic conditions of pH and temperature.
引用
收藏
页码:345 / 355
页数:11
相关论文
共 50 条
  • [1] Towards an implantable biochip for glucose and lactate monitoring using microdisc electrode arrays (MDEAs)
    Abdur Rub Abdur Rahman
    Gusphyl Justin
    Anthony Guiseppi-Elie
    Biomedical Microdevices, 2009, 11
  • [2] Towards an implantable biochip for glucose and lactate monitoring using microdisc electrode arrays (MDEAs)
    Abdur Rahman, Abdur Rub
    Justin, Gusphyl
    Guiseppi-Elie, Anthony
    BIOMEDICAL MICRODEVICES, 2009, 11 (01) : 75 - 85
  • [3] Design of Implantable MSA for Glucose Monitoring
    Khadase, R.
    Nandgaonkar, A.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING 2016 (ICCASP 2016), 2017, 137 : 637 - 641
  • [4] Miniature Implantable Antenna Design for Blood Glucose Monitoring
    Ahmed, Ayesha
    Ur-Rehman, Masood
    Abbasi, Qammer Hussain
    2018 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM (ACES), 2018,
  • [5] Design and Study of a Small Implantable Antenna Design for Blood Glucose Monitoring
    Ahmed, Ayesha
    Kalsoom, Tahera
    Ur-Rehman, Masood
    Ramzan, Naeem
    Karim, Sajjad
    Abbasi, Qammer H.
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2018, 33 (10): : 1146 - 1151
  • [6] Biochip for minimally invasive blood glucose monitoring
    Zhang, Peiyu
    Ahmadi, M. M.
    Jullien, G. A.
    NANOTECH CONFERENCE & EXPO 2009, VOL 2, TECHNICAL PROCEEDINGS: NANOTECHNOLOGY 2009: LIFE SCIENCES, MEDICINE, DIAGNOSTICS, BIO MATERIALS AND COMPOSITES, 2009, : 209 - 212
  • [7] Design and Analysis of a Small Implantable Antenna for Blood Glucose Monitoring
    Angeline, Nivitha J.
    Christe, Allin S.
    2020 5TH INTERNATIONAL CONFERENCE ON DEVICES, CIRCUITS AND SYSTEMS (ICDCS' 20), 2020, : 120 - 124
  • [8] IMPLANTABLE GLUCOSE AND KETONE MONITORING
    De Block, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A2 - A3
  • [9] Multilayered implantable antenna biosensor for continuous glucose monitoring: Design and analysis
    Khadase R.B.
    Nandgaonkar A.
    Iyer B.
    Wagh A.
    Progress In Electromagnetics Research C, 2021, 114 : 173 - 184
  • [10] Remote monitoring of subcutaneous implantable cardioverter defibrillators
    De Filippo, Paolo
    Luzi, Mario
    D'Onofrio, Antonio
    Bongiorni, Maria Grazia
    Giammaria, Massimo
    Bisignani, Giovanni
    Menardi, Endrj
    Ferrari, Paola
    Bianchi, Valter
    Viani, Stefano
    Leidi, Cristina
    Lovecchio, Mariolina
    Valsecchi, Sergio
    Capucci, Alessandro
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (03) : 373 - 381