Efficient procedure to evaluate electromagnetic transients on three-phase transmission lines

被引:30
|
作者
Costa, E. C. M. [1 ]
Kurokawa, S. [2 ]
Pissolato, J. [1 ]
Prado, A. J. [2 ]
机构
[1] Unicamp Univ Estadual Campinas, BR-13081970 Campinas, SP, Brazil
[2] Unesp Univ Estadual Paulista, BR-15385000 Ilha Solteira, SP, Brazil
关键词
TRANSFORMATION-MATRICES; PARAMETERS;
D O I
10.1049/iet-gtd.2009.0660
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a hybrid way mixing time and frequency domain for transmission lines modelling. The proposed methodology handles steady fundamental signal mixed with fast and slow transients, including impulsive and oscillatory behaviour. A transmission line model is developed based on lumped elements representation and state-space techniques. The proposed methodology represents an easy and practical procedure to model a three-phase transmission line directly in time domain, without the explicit use of inverse transforms. The proposed methodology takes into account the frequency-dependent parameters of the line, considering the soil and skin effects. In order to include this effect in the state matrices, a fitting method is applied. Furthermore the accuracy of proposed the developed model is verified, in frequency domain, by a simple methodology based on line distributed parameters and transfer function related to the input/output signals of the lumped parameters representation. In addition, this article proposes the use of a fast and robust analytic integration procedure to solve the state equations, enabling transient and steady-state simulations. The results are compared with those obtained by the commercial software Microtran (EMTP), taking into account a three-phase transmission line, typical in the Brazilian transmission system.
引用
收藏
页码:1069 / 1081
页数:13
相关论文
共 50 条
  • [31] AN EFFICIENT PROCEDURE FOR THE IMPLEMENTATION OF CORONA MODELS IN ELECTROMAGNETIC TRANSIENTS PROGRAMS
    CARNEIRO, S
    DOMMEL, HW
    MARTI, JR
    BARROS, HM
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (02) : 849 - 855
  • [32] Transient analysis of three-phase transmission lines with initial voltage and current distributions
    Natl Taiwan Ocean Univ, Keelung, Taiwan
    Electr Power Syst Res, 3 (177-186):
  • [33] Three-phase electromagnetic AC motors
    Smirnov Y.V.
    Russian Electrical Engineering, 2009, 80 (05) : 244 - 246
  • [34] Identification of three-phase permanent or temporary fault at transmission lines with shunt reactors
    Li, Yong-Li
    Li, Bo-Tong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (01): : 82 - 90
  • [35] Transient analysis of three-phase transmission lines with initial voltage and current distributions
    Li, JC
    ELECTRIC POWER SYSTEMS RESEARCH, 1995, 35 (03) : 177 - 186
  • [36] Single real transformation matrices applied to double three-phase transmission lines
    Campos, J. C. C.
    Pissolato Filho, J.
    Prado, A. J.
    Kurokawa, S.
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (10) : 1719 - 1725
  • [37] A frequency dependent mode domain model for double three-phase transmission lines
    Prado, AJ
    Pissolato, J
    Tavares, MC
    Portela, CM
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 1059 - 1064
  • [38] Harmonic impedance measurement using three-phase transients
    Nagpal, M
    Xu, W
    Sawada, J
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (01) : 272 - 277
  • [39] Fluctuations in the structure of three-phase lines
    Cornell Univ, Ithaca, United States
    Physica A: Statistical Mechanics and its Applications, 1998, 251 (1-2): : 27 - 39
  • [40] Fluctuations in the structure of three-phase lines
    Bukman, DJ
    Widom, B
    PHYSICA A, 1998, 251 (1-2): : 27 - 39