Assessment of a membrane drinking water filter in an emergency setting

被引:4
|
作者
Ensink, Jeroen H. J. [1 ]
Bastable, Andy [2 ]
Cairncross, Sandy [1 ]
机构
[1] London Sch Hyg & Trop Med, Environm Hlth Grp, London WC1E 7HT, England
[2] Oxfam GB, Oxford OX2 7DZ, England
关键词
acceptability; emergency; household water treatment; Nerox (TM) filter; use; POOR;
D O I
10.2166/wh.2014.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance and acceptability of the Nerox (TM) membrane drinking water filter were evaluated among an internally displaced population in Pakistan. The membrane filter and a control ceramic candle filter were distributed to over 3,000 households. Following a 6-month period, 230 households were visited and filter performance and use were assessed. Only 6% of the visited households still had a functioning filter, and the removal performance ranged from 80 to 93%. High turbidity in source water (irrigation canals), together with high temperatures and large family size were likely to have contributed to poor performance and uptake of the filters.
引用
收藏
页码:362 / 370
页数:9
相关论文
共 50 条
  • [21] Application of membrane technology for drinking water
    Ma, WT
    Sun, ZC
    Wang, ZX
    Feng, YB
    Wang, TC
    Chan, US
    Miu, CH
    Zhu, SC
    DESALINATION, 1998, 119 (1-3) : 127 - 131
  • [22] Drinking water treatment with membrane ultrafiltration
    Barlokova, D.
    Ilavsky, J.
    Marton, M.
    ADVANCES IN ENVIRONMENTAL ENGINEERING (AEE2019), 2020, 444
  • [23] DRINKING-WATER AND ZEOLITE MEMBRANE
    SUZUKI, H
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 193 - ENVR
  • [24] Membrane bioreactor for drinking water denitrification
    Barreiros, AM
    Rodrigues, CM
    Crespo, JPSG
    Reis, MAM
    BIOPROCESS ENGINEERING, 1998, 18 (04) : 297 - 302
  • [25] Membrane bioreactor for drinking water denitrification
    A. M. Barreiros
    C. M. Rodrigues
    J. P. S. G. Crespo
    M. A. M. Reis
    Bioprocess Engineering, 1998, 18 : 297 - 302
  • [26] USE OF MICROBIAL RISK ASSESSMENT IN SETTING UNITED-STATES DRINKING-WATER STANDARDS
    MACLER, BA
    REGLI, S
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1993, 18 (04) : 245 - 256
  • [27] Emergency preparedness for drinking water and wastewater systems
    US Environmental Protection Agency, United States
    J Am Water Works Assoc, 2007, 3 (36-38):
  • [28] Evaluation of semidecentralized emergency drinking water treatment
    Eloidin, Oceane
    Dorea, Caetano C.
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2015, 50 (10): : 1040 - 1045
  • [29] Emergency preparedness for drinking water and wastewater systems
    Whitler, John
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2007, 99 (03): : 36 - 38
  • [30] Comparison of UV and chlorine pretreatment in pilot plant micro-filter membrane separation for drinking water
    Research Development Department, Maezawa Industries, INC., 5-11 Nakachuo, Kawaguchi, Saitama 332-8556, Japan
    Water Sc. Technol. Water Supply, 5-6 (245-251):