Influence of thermal treatment duration on structure and phase composition of additive Co-Cr-Mo alloy samples

被引:3
|
作者
Khimich, M. A. [1 ,2 ]
Ibragimov, E. A. [3 ]
Tolmachev, A., I [1 ]
Chebodaeva, V. V. [1 ]
Uvarkin, P., V [1 ]
Saprykina, N. A. [3 ]
Saprykin, A. A. [3 ]
Sharkeev, Yu P. [1 ,3 ]
机构
[1] RAS, Siberian Branch, Inst Strength Phys & Mat Sci, Tomsk 634055, Russia
[2] Natl Res Tomsk State Univ, Tomsk 634050, Russia
[3] Natl Res Tomsk Polytech Univ, Tomsk 634050, Russia
来源
LETTERS ON MATERIALS | 2022年 / 12卷 / 01期
关键词
laser powder bed fusion; raw elemental powders; Co-Cr-Mo alloys; thermal treatment; structure; phase composition; MECHANICAL-PROPERTIES; HEAT-TREATMENT; COCRMO ALLOYS; SIGMA-PHASE; TI-NB; BEHAVIOR; MICROSTRUCTURE; POWDERS; TRANSFORMATION; TI-6AL-7NB;
D O I
10.22226/2410-3535-2022-1-43-48
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Laser powder bed fusion (LPBF) requires application of powders with specific characteristics. These are near-spherical shape of particles, uniform elemental composition, typical particle size of 5 - 70 mu m, etc. Such powders are produced by spheroidization methods. They have such disadvantages as high cost and sale only in large quantities. There are publications describing application in LPBF powders, produced by the methods, alternative to spheroidiz,ation. In the current study, powders of pure raw Co, Cr and Mo were used for the production of Co-Cr-Mo powder mixture. Samples of Co-28 wt.% Cr-6 wt.% Mo alloy were produced by LPBF from this powder mixture. Due to the difference between melting temperatures of Co, Cr and Mo, inclusions of Cr and Mo were formed within the bulk of samples. Studies of phase and elemental composition, structure and microhardness of the as-produced samples and after post-treatment with varied duration are represented. As-produced samples have non-uniform elemental composition and are represented by the main Co-based phase. Increasing the annealing duration leads to the sequential dissolution of un-melted Cr and Mo inclusions. Complete dissolution of Cr particles was observed at 10 hours of treatment and complete dissolution of Mo particles was not observed after 20 hours of annealing. Microhardness non-linearly changes with the increasing duration of annealing. This is due to the phase transformations and diffusion processes occurring at such type of post-treatment. Complete dissolution of Mo-particles could be achieved by further increasing the annealing time or by varying the mode of laser powder bed fusion.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 50 条
  • [41] The effect of ion implantation on the wear of Co-Cr-Mo alloy
    Werner, Z.
    Barlak, M.
    Gradzka-Dahlke, M.
    Diduszko, R.
    Szymczyk, W.
    Dabrowski, J.
    Piekoszewski, J.
    Borkowska, K.
    VACUUM, 2007, 81 (10) : 1191 - 1194
  • [42] TWIN-TWIN INTERACTION IN A CO-CR-MO ALLOY
    RAJAN, K
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1982, 1 (11) : 482 - 484
  • [43] Effect of nitriding treatment on corrosion behaviour of Co-Cr-Mo alloy in liquid Al
    Tang, Ning
    Li, Yunping
    Koizumi, Yuichiro
    Chiba, Akihiko
    CORROSION SCIENCE, 2014, 78 : 244 - 250
  • [44] Characterization of Co-Cr-Mo alloys after a thermal treatment for high wear resistance
    Balagna, C.
    Spriano, S.
    Faga, M. G.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (07): : 1868 - 1877
  • [45] The Effect of Cyclic Solution Heat Treatment on the Martensitic Phase Transformation and Grain Refinement of Co-Cr-Mo Dental Alloy
    Zangeneh, Shahab
    Lashgari, Hamid Reza
    Alsaadi, Shaimaa
    Mohamad-Moradi, Sara
    Saghafi, Morteza
    METALS, 2020, 10 (07) : 1 - 17
  • [46] Prediction of influence of Co-Cr-Mo alloy coating on the wear rate of aluminium with HCl solution
    Reddy, Pratapa Y.
    Narayana, Lakshmi K.
    Mallik, M. Kedar
    MATERIALS TODAY-PROCEEDINGS, 2021, 42 : 1287 - 1296
  • [47] Microscopic mechanism of plastic deformation in a polycrystalline Co-Cr-Mo alloy with a single hcp phase
    Matsumoto, Hiroaki
    Koizumi, Yuichiro
    Ohashi, Tetsuya
    Lee, Byong-Soo
    Li, Yunping
    Chiba, Akihiko
    ACTA MATERIALIA, 2014, 64 : 1 - 11
  • [48] Application of Harmonic Structure Design to Biomedical Co-Cr-Mo Alloy for Improved Mechanical Properties
    Sawangrat, Choncharoen
    Yamaguchi, Osamu
    Vajpai, Sanjay Kumar
    Ameyama, Kei
    MATERIALS TRANSACTIONS, 2014, 55 (01) : 99 - 105
  • [49] MICROSTRUCTURAL CHANGES DURING ISOTHERMAL FORGING OF A CO-CR-MO ALLOY
    IMMARIGEON, JP
    RAJAN, K
    WALLACE, W
    METALLURGICAL TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1984, 15 (02): : 339 - 345
  • [50] Interfacial reaction between Co-Cr-Mo alloy and liquid Al
    Tang, Ning
    Li, Yunping
    Koizumi, Yuichiro
    Kurosu, Shingo
    Chiba, Akihiko
    CORROSION SCIENCE, 2013, 75 : 262 - 268