Repeatability of central corneal thickness measurements of donor corneas in preservation chamber using Fourier-domain anterior segment optical coherence tomography

被引:5
|
作者
Golla, Abhinav [1 ]
Wang, Li [1 ]
Morris, Caleb [1 ]
Weikert, Mitchell P. [1 ,2 ]
Khandelwal, Sumitra S. [1 ,2 ]
机构
[1] Baylor Coll Med, Cullen Eye Inst, 6565 Fannin St NC505B, Houston, TX 77030 USA
[2] Lions Eye Bank Texas, 1977 Butler Blvd, Houston, TX 77030 USA
关键词
Central corneal thickness; Optical coherence tomography; Repeatability; Donor cornea; Preservation;
D O I
10.1007/s10561-018-9724-z
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
To evaluate the repeatability of central corneal thickness (CCT) measurements in donor corneas using optical coherence tomography (OCT, RTVueOptovue, Inc., Fremont, CA). Consecutive corneas were measured by a single observer using the RTVue. All corneas were preserved in the Transend chamber and Life4 degrees C media (Numedis, Inc., Isanti, MN/USA) and stored at 4 degrees C. The repeatability was evaluated using a pooled within-subject standard deviation (SD), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). To investigate inter-observer repeatability, a second observer independently measured the CCT for each image scan. CCT was measured in 32 eyes from 18 donors. Measurements were independently repeated by a second observer. The corneas had a mean CCT of 490.99m +/- 65.95 (381-642) as measured by Observer 1. For observer 1, the SD value for the CCT was 2.94m, the CoV value was 0.597%, and the ICC value was 0.998 (95% CI 0.996, 0.999). For observer 2, the SD value was 5.91m, the CoV value was 1.21%, and the ICC value was 0.992 (95% CI 0.985, 0.996). The Kappa statistic 21.88% with a p value<0.001. The Bland-Altman plot shows that the average CCT measurements between the two observers were within 20m of each other. The CCT measurements of donor corneas in the preservation chamber using Fourier domain OCT is highly repeatable.
引用
收藏
页码:717 / 720
页数:4
相关论文
共 50 条
  • [21] The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography
    Sin, Sokpheaktra
    Simpson, Trefford L.
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (06) : 360 - 365
  • [22] Study of Anterior Chamber Aqueous Tube Shunt by Fourier-Domain Optical Coherence Tomography
    Jiang, Chunhui
    Li, Yan
    Huang, David
    Francis, Brian A.
    JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [23] Anterior Segment Optical Coherence Tomography Versus Ultrasound Pachymetry to Measure Corneal Thickness in Endothelial Keratoplasty Donor Corneas
    Fante, Ryan J.
    Shtein, Roni M.
    Titus, Michael S.
    Woodward, Maria A.
    CORNEA, 2013, 32 (05) : E79 - E82
  • [24] Lower Tear Meniscus Measurements Using a New Anterior Segment Swept-Source Optical Coherence Tomography and Agreement With Fourier-Domain Optical Coherence Tomography
    Arriola-Villalobos, Pedro
    Ignacio Fernandez-Vigo, Jose
    Diaz-Valle, David
    Almendral-Gomez, Jaime
    Fernandez-Perez, Cristina
    Benitez-del-Castillo, Jose M.
    CORNEA, 2017, 36 (02) : 183 - 188
  • [25] Repeatability of laser in situ keratomileusis flap thickness measurement by Fourier-domain optical coherence tomography
    Rosas Salaroli, Camila Haydee
    Li, Yan
    Zhang, Xinbo
    Tang, Maolong
    Ramos, Jose Luiz Branco
    Allemann, Norma
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04): : 649 - 654
  • [26] Corneal power measurement with Fourier-domain optical coherence tomography
    Tang, Maolong
    Chen, Alex
    Li, Yan
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2115 - 2122
  • [27] Repeatability of Pachymetric Mapping Using Fourier Domain Optical Coherence Tomography in Corneas With Opacities
    El Gendy, Nehal M. Samy
    Li, Yan
    Zhang, Xinbo
    Huang, David
    CORNEA, 2012, 31 (04) : 418 - 423
  • [28] Anterior Chamber Angle Measurements Using Schwalbe's Line With High-resolution Fourier-Domain Optical Coherence Tomography
    Qin, Bing
    Francis, Brian A.
    Li, Yan
    Tang, Maolong
    Zhang, Xinbo
    Jiang, Chunhui
    Cleary, Catherine
    Huang, David
    JOURNAL OF GLAUCOMA, 2013, 22 (09) : 684 - 688
  • [29] Macular thickness of Chinese with fourier-domain optical coherence tomography
    Yu Weihong
    Zheng Lin
    Dai Rongping
    Zhang Zhiqiao
    Dong Fangtian
    ACTA OPHTHALMOLOGICA, 2011, 89 (01) : E104 - E105
  • [30] Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry
    Zhao, Paul S.
    Wong, Tien Yin
    Wong, Wan-Ling
    Saw, Seang-Mei
    Aung, Tin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) : 1047 - 1049