摘要
Precision errors that occur in estimating the average scatterer size from pulse-echo ultrasound waveforms are examined in detail. The method-independent lower bound on estimation error is found from the Cramer-Rao inequality for comparison with the predicted error for the measurement technique currently used to estimate scatterer sizes in soft biological tissues. The probability density function for the estimate is also derived. From these statistical analyses, strategies for designing experiments that minimize the error are discussed. It is shown that compared with biological variability, measurement errors in scatterer size estimates are relatively large. Consequently, there is reason to continue searching for more efficient estimators. Although the analysis and results are derived for Gaussian correlation models that have been used to study the function and structure of kidneys, generalization to include correlation models for other tissues is straightforward. (C) 1996 Acoustical Society of America.
引用
收藏
页码:392 / 399
页数:8
相关论文
共 50 条
  • [1] Errors in ultrasonic scatterer size estimates due to phase and amplitude aberration
    Gerig, A. (algerig@wisc.edu), 1600, Acoustical Society of America (115):
  • [2] Errors in ultrasonic scatterer size estimates due to phase and amplitude aberration
    Gerig, A
    Zagzebski, J
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (06): : 3244 - 3252
  • [3] Correlation of ultrasonic scatterer size estimates for the statistical analysis and optimization of angular compounding
    Gerig, A
    Chen, Q
    Zagzebski, J
    Varghese, T
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 116 (03): : 1832 - 1841
  • [4] Effective Scatterer Diameter Estimates for Broad Scatterer Size Distributions
    Nordberg, Eric P.
    Hall, Timothy J.
    ULTRASONIC IMAGING, 2015, 37 (01) : 3 - 21
  • [5] Methods for Improvement on Liver Scatterer Size Estimates
    Liu, Wu
    Zagzebski, James A.
    Gerig, Anthony L.
    Varghese, Tomy
    Marquez, Eibsee C.
    Kliewer, Mark A.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 641 - +
  • [6] Spectral analysis for ultrasonic scatterer size estimation
    Yang, F.-J.
    Tsao, J.
    Lin, W.-L.
    Shieh, M.-J.
    Biomedical Engineering - Applications, Basis and Communications, 1999, 11 (03): : 159 - 165
  • [7] Using resolution enhancement compression to reduce variance of scatterer size estimates from ultrasonic backscattered signals
    Sanchez, Jose R.
    Pocci, Darren
    Oelze, Michael L.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 36 - 39
  • [8] ERROR IN ESTIMATES OF SIZE
    MCMAHON, R
    GASTROINTESTINAL ENDOSCOPY, 1994, 40 (06) : 779 - 780
  • [9] Statistics of ultrasonic scatterer size estimation with a reference phantom
    Gerig, A. (algerig@wisc.edu), 1600, Acoustical Society of America (113):
  • [10] Autoregressive spectral estimation in ultrasonic scatterer size imaging
    Department of Radiology, University of Kansas, Medical Center, Kansas City, KS 66160-7234, United States
    ULTRASON. IMAGING, 1 (10-24):