Application of Sacrificial Point Anode for Prevention of Steel Corrosion in Cracked Concrete

被引:5
|
作者
Caronge, Muhammad Akbar [1 ]
Hamada, Hidenori [2 ]
Irmawaty, Rita [3 ]
Sagawa, Yasutaka [2 ]
Yamamoto, Daisuke [2 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Fukuoka, Japan
[2] Kyushu Univ, Dept Civil Engn, Fukuoka, Japan
[3] Hasanuddin Univ, Dept Civil Engn, Makassar, Indonesia
关键词
CATHODIC PROTECTION;
D O I
10.3151/jact.13.479
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effectiveness of a commercially available sacrificial point anode for corrosion prevention of steel in cracked concrete is presented. Reinforced concrete prisms with dimensions of 150 mm x 150 mm x 500 mm were prepared with a water to cement ratio (W/C) of 0.4 showing crack widths ranging from 0.1 to 0.4 mm obtained by pre-cracking. These specimens were exposed to three conditions: (1) laboratory air (temperature of 20 +/- 2 degrees C and relative humidity of 60%); (2) immersed in 3% NaCl solution; and (3) dry/wet cycles of above mentioned conditions. Measurements included the free corrosion potential, polarization behavior of the sacrificial point anode, anodic-cathodic polarization curve of the reinforcement steel and visual observation. The test results show that the sacrificial point anode was effective to prevent the embedded steel from corrosion in cracked concrete. Specimens exposed to dry/wet cycles or immersed in 3% NaCl solution demonstrated a better protection than those exposed to laboratory air due to the high moisture condition. Thus, a sacrificial point anode becomes active to protect the steel bars even in cracked concrete.
引用
收藏
页码:479 / 488
页数:10
相关论文
共 50 条
  • [1] Study for prevention of steel corrosion by sacrificial anode cathodic protection
    A. S. Yaro
    K. W. Hameed
    A. A. Khadom
    Theoretical Foundations of Chemical Engineering, 2013, 47 : 266 - 273
  • [2] Study for prevention of steel corrosion by sacrificial anode cathodic protection
    Yaro, A. S.
    Hameed, K. W.
    Khadom, A. A.
    THEORETICAL FOUNDATIONS OF CHEMICAL ENGINEERING, 2013, 47 (03) : 266 - 273
  • [4] CORROSION OF STEEL IN CRACKED CONCRETE
    BERKE, NS
    DALLAIRE, MP
    HICKS, MC
    HOOPES, RJ
    CORROSION, 1993, 49 (11) : 934 - 943
  • [5] CORROSION OF STEEL IN CRACKED CONCRETE
    BERKE, NS
    DALLAIRE, MP
    HICKS, MC
    HOOPES, RJ
    CORROSION, 1994, 50 (10) : 781 - 784
  • [6] Prevention of steel corrosion in concrete exposed to seawater with submerged sacrificial anodes
    Bertolini, L
    Gastaldi, M
    Pedeferri, M
    Redaelli, E
    CORROSION SCIENCE, 2002, 44 (07) : 1497 - 1513
  • [7] Chloride corrosion of steel in cracked concrete
    Rehm, Gallus
    Nuernberger, Ulf
    Neubert, Bernd
    Deutscher Ausschuss fuer Stahlbeton, 1988, (390): : 43 - 156
  • [8] CORROSION OF STEEL IN CRACKED CONCRETE - DISCUSSION
    MCDONALD, DB
    CORROSION, 1994, 50 (06) : 419 - 421
  • [9] Corrosion of steel in cracked concrete: Experimental investigation
    Bi, M.
    Subramaniam, K.
    MEASURING, MONITORING AND MODELING CONCRETE PROPERTIES, 2006, : 557 - +
  • [10] Corrosion of steel in cracked concrete: A microscale study
    Pacheco, J.
    Savija, B.
    Schlangen, E.
    Polder, R. B.
    CONCRETE SOLUTIONS: PROCEEDINGS OF CONCRETE SOLUTIONS, 5TH INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, 2014, : 551 - 557