Application of Sacrificial Point Anode for Prevention of Steel Corrosion in Cracked Concrete

被引:5
|
作者
Caronge, Muhammad Akbar [1 ]
Hamada, Hidenori [2 ]
Irmawaty, Rita [3 ]
Sagawa, Yasutaka [2 ]
Yamamoto, Daisuke [2 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Fukuoka, Japan
[2] Kyushu Univ, Dept Civil Engn, Fukuoka, Japan
[3] Hasanuddin Univ, Dept Civil Engn, Makassar, Indonesia
关键词
CATHODIC PROTECTION;
D O I
10.3151/jact.13.479
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effectiveness of a commercially available sacrificial point anode for corrosion prevention of steel in cracked concrete is presented. Reinforced concrete prisms with dimensions of 150 mm x 150 mm x 500 mm were prepared with a water to cement ratio (W/C) of 0.4 showing crack widths ranging from 0.1 to 0.4 mm obtained by pre-cracking. These specimens were exposed to three conditions: (1) laboratory air (temperature of 20 +/- 2 degrees C and relative humidity of 60%); (2) immersed in 3% NaCl solution; and (3) dry/wet cycles of above mentioned conditions. Measurements included the free corrosion potential, polarization behavior of the sacrificial point anode, anodic-cathodic polarization curve of the reinforcement steel and visual observation. The test results show that the sacrificial point anode was effective to prevent the embedded steel from corrosion in cracked concrete. Specimens exposed to dry/wet cycles or immersed in 3% NaCl solution demonstrated a better protection than those exposed to laboratory air due to the high moisture condition. Thus, a sacrificial point anode becomes active to protect the steel bars even in cracked concrete.
引用
收藏
页码:479 / 488
页数:10
相关论文
共 50 条
  • [11] CHLORIDE CORROSION OF REINFORCING STEEL IN CRACKED CONCRETE
    OKADA, K
    MIYAGAWA, T
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1980, 77 (05): : 381 - 381
  • [12] Factors affecting sacrificial anode to protect reinforcing steel corrosion
    Sancharoen, P.
    Mahasiripan, A.
    Tangtermsirikul, S.
    LIFE-CYCLE OF ENGINEERING SYSTEMS: EMPHASIS ON SUSTAINABLE CIVIL INFRASTRUCTURE, 2017, : 2297 - 2302
  • [13] Sacrificial anode protection of an underground steel reinforced concrete structure
    Kessler, RJ
    Powers, RG
    Lasa, IR
    MATERIALS PERFORMANCE, 1998, 37 (03) : 10 - 13
  • [14] Corrosion rate of reinforcing steel bars in cracked concrete
    Tsukahara, Ema
    Uomoto, Taketo
    Transactions of the Japan Concrete Institute, 2000, 22 : 155 - 166
  • [15] Cathodic Prevention and Cathodic Protection of Concrete Slab with Zinc Sacrificial Anode
    Jeong, Jin-A
    Advance Materials Development and Applied Mechanics, 2014, 597 : 341 - 344
  • [16] Study on the Splash Zone Corrosion Protection of Carbon Steel by Sacrificial Anode
    Chen, Jun
    Huang, Yanliang
    Dong, Xiqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (05): : 4114 - 4120
  • [17] Prevention of Corrosion of Steel Reinforcement in Concrete
    Patel, Rahul
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SUSTAINABLE MATERIALS AND STRUCTURES FOR CIVIL INFRASTRUCTURES (SMSCI2019), 2019, 2158
  • [18] Cathode corrosion prevention of steel in concrete
    Eichler, Thorsten
    Isecke, Bernd
    Klein, Hans-H.
    Schade, Andreas
    Pruckner, Franz
    Michel, Stefan
    BETON- UND STAHLBETONBAU, 2007, 102 (05) : 310 - 320
  • [19] Localized corrosion propagation of steel in cracked mortar and long-term corrosion of steel reinforcement in cracked concrete in seawater environment
    Feng, Guangyan
    Jin, Zuquan
    Jiang, Yudan
    Wang, Xiaoxian
    Zhu, Deju
    CORROSION SCIENCE, 2024, 228
  • [20] Localized Corrosion of Embedded Steel in Cracked Reinforced Concrete Pipes
    Busba, E.
    Saguees, A. A.