Prevention of steel corrosion in concrete exposed to seawater with submerged sacrificial anodes

被引:90
|
作者
Bertolini, L [1 ]
Gastaldi, M [1 ]
Pedeferri, M [1 ]
Redaelli, E [1 ]
机构
[1] Politecn Milan, Dipartimento Chim Fis Applicata, I-20133 Milan, Italy
关键词
reinforced concrete; chlorides; cathodic protection; cathodic prevention; sacrificial anode; throwing power; potential decay;
D O I
10.1016/S0010-938X(01)00168-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents the results of a study of the effectiveness of submerged sacrificial anodes in preventing the onset of pitting corrosion in the emerged part of marine piles. Experimental tests were carried out on reinforced concrete columns with steel embedded both in chloride free concrete and chloride contaminated concrete in order to compare the effects of sacrificial anodes on passive steel and on corroding steel. Results have shown, at least under the present testing conditions, that sacrificial anodes may be more effective in preventing corrosion initiation (i.e. in providing cathodic prevention) than in controlling ongoing pitting corrosion (i.e. in guaranteeing cathodic protection). Monitoring criteria for this type of prevention are also discussed. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1497 / 1513
页数:17
相关论文
共 50 条
  • [1] EVALUATION OF THE THROWING POWER OF CATHODIC PREVENTION WITH SACRIFICIAL ANODES APPLIED TO REINFORCED CONCRETE PILES PARTIALLY SUBMERGED IN SEAWATER
    Bertolini, L.
    Redaelli, E.
    METALLURGIA ITALIANA, 2008, (05): : 43 - 48
  • [2] Application of Sacrificial Point Anode for Prevention of Steel Corrosion in Cracked Concrete
    Caronge, Muhammad Akbar
    Hamada, Hidenori
    Irmawaty, Rita
    Sagawa, Yasutaka
    Yamamoto, Daisuke
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2015, 13 (10) : 479 - 488
  • [3] AC Corrosion behaviour of aluminium and zinc sacrificial anodes in seawater
    Tian, Nianpei
    Du, Yanxia
    Liang, Yi
    Yuan, Xun
    Chen, Le
    CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2022, 57 (02) : 169 - 177
  • [4] Corrosion mitigation of CFRP-steel interface with sacrificial anodes
    Kim, Yail J.
    Chai, Yufei
    Yoshitake, Isamu
    COMPOSITE INTERFACES, 2019, 26 (07) : 625 - 641
  • [5] Sacrificial Point Anodes for Cathodic Prevention of Reinforcing Steel in Concrete Repairs: Part 1-Polarization Behavior
    Dugarte, M. J.
    Saguees, A. A.
    CORROSION, 2014, 70 (03) : 303 - 317
  • [6] Sacrificial Point Anodes for Cathodic Prevention of Reinforcing Steel in Concrete Repairs-Part 2: Performance Modeling
    Dugarte, M. J.
    Saguees, A. A.
    CORROSION, 2014, 70 (04) : 414 - 429
  • [7] Effect of Al on the Intergranular Corrosion of Zn–Al Sacrificial Anodes in Seawater at 80 °C
    Lin Yu
    Zhaoxin Liu
    Haitao Wang
    Xu Shi
    Tingyong Wang
    Journal of Materials Engineering and Performance, 2023, 32 : 6876 - 6884
  • [8] Throwing power of cathodic prevention applied by means of sacrificial anodes to partially submerged marine reinforced concrete piles: Results of numerical simulations
    Bertolini, Luca
    Redaelli, Elena
    CORROSION SCIENCE, 2009, 51 (09) : 2218 - 2230
  • [9] TITANIUM ANODES FOR THE CATHODIC CORROSION PROTECTION OF STEEL IN CONCRETE
    KOTOWSKI, S
    BUSSE, B
    BEDEL, R
    METALL, 1988, 42 (02): : 133 - 140
  • [10] Prevention of Corrosion of Steel Reinforcement in Concrete
    Patel, Rahul
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SUSTAINABLE MATERIALS AND STRUCTURES FOR CIVIL INFRASTRUCTURES (SMSCI2019), 2019, 2158