Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT

被引:278
|
作者
Kachelriess, M
Watzke, O
Kalender, WA
机构
[1] Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen
关键词
computed tomography (CT); multi-slice spiral CT (MSCT); cone-beam CT (CBCT); artifact reduction; noise reduction; dose reduction; adaptive filters;
D O I
10.1118/1.1358303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In modern computed tomography (CT) there is a strong desire to reduce patient dose and/or to improve image quality by increasing spatial resolution and decreasing image noise. These are conflicting demands since increasing resolution at a constant noise level or decreasing noise at a constant resolution level implies a higher demand on x-ray power and an increase of patient dose. X-ray tube power is limited due to technical reasons. We therefore developed a generalized multi-dimensional adaptive filtering approach that applies nonlinear filters in up to three dimensions in the raw data domain. This new method differs from approaches in the literature since our nonlinear filters are applied not only in the detector row direction but also in the view and in the z-direction. This true three-dimensional filtering improves the quantum statistics of a measured projection Value proportional to the third power of the filter size. Resolution tradeoffs are shared among these three dimensions and thus are considerably smaller as compared to one-dimensional smoothing approaches. Patient data of spiral and sequential single- and multi-slice CT scans as well as simulated spiral cone-beam data were processed to evaluate these new approaches. Image quality was assessed by evaluation of difference images, by measuring the image noise and the noise reduction, and by calculating the image resolution using point spread functions. The use of generalized adaptive filters helps to reduce image noise or, alternatively, patient dose. Image noise structures, typically along the direction of the highest attenuation, are effectively reduced. Noise reduction values of typically 30%-60% can be achieved in noncylindrical body regions like the shoulder. The loss in image resolution remains below 5% for all cases. In addition, the new method has a great potential to reduce metal artifacts, e.g., in the hip region. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:475 / 490
页数:16
相关论文
共 50 条
  • [21] Technical advances in multi-slice spiral CT
    Fuchs, T
    Kachelriess, M
    Kalender, WA
    EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) : 69 - 73
  • [22] Radiation exposure of the head, midface and pelvis in multi-slice CT (MSCT):: Comparison with single-slice CT (SSCT)
    Wedegärtner, U
    Thurmann, H
    Schmidt, R
    Adam, G
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (02): : 234 - 238
  • [23] Feasibility of Dose Calculation Using Combined Information of Cone-Beam and Multi-Slice CT Images
    Usui, K.
    Ogawa, K.
    Kunieda, E.
    MEDICAL PHYSICS, 2012, 39 (06) : 3675 - 3675
  • [24] Comparison among peoperative single-slice CT and multi-slice CT in simple, closed, loop and strangulating bowel obstruction
    Assenza, Marco
    Ricci, Gabriele
    Macciucca, Marina De Vargas
    Polettini, Elisabetta
    Casciani, Emanuele
    De Cicco, Maria Luisa
    Gualdi, Gianfranco
    Modini, Claudio
    HEPATO-GASTROENTEROLOGY, 2007, 54 (79) : 2017 - 2023
  • [25] The effect of pitch in multi-slice spiral/helical CT
    Wang, G
    Vannier, MW
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 116 - 127
  • [26] Characterization of motion artifacts in multi-slice spiral CT
    Graf, H
    Heuschmid, M
    Küttner, A
    Kopp, AF
    Claussen, CD
    Schick, F
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (10): : 1301 - 1308
  • [27] Cone-Beam CT Compared to Multi-Slice CT for the Diagnostic Analysis of Conductive Hearing Loss: A Feasibility Study
    Kemp, Pieter
    Van Stralen, Jiska
    De Graaf, Pim
    Berkhout, Erwin
    Van Horssen, Pepijn
    Merkus, Paul
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2020, 16 (02): : 222 - +
  • [28] Kymogram- vs ECG-correlated imaging from subsecond multi-slice and cone-beam spiral CT scans of the heart
    Kachelriess, M
    Sennst, D
    Maxlmoser, W
    Kalender, WA
    RADIOLOGY, 2001, 221 : 458 - 458
  • [29] Radiation dose delivered by mobile CT unit for examination of patients in emergency: Comparison with stationary single-slice and multi-slice CT
    Hidajat, N
    Wolf, M
    Nunnemann, A
    Telchgraeber, UK
    Bittner, R
    Felix, R
    RADIOLOGY, 2000, 217 : 537 - 537
  • [30] Single-slice reconstruction method for helical cone-beam differential phase-contrast CT
    Fu, Jian
    Chen, Liyuan
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 45 - 51