A new approach to heart valve tissue engineering: mimicking the heart ventricle with a ventricular assist device in a novel bioreactor

被引:5
|
作者
Kaasi, Andreas [1 ,3 ,4 ,5 ]
Cestari, Idagene A. [1 ]
Stolf, Noedir A. G. [2 ]
Leirner, Adolfo A. [1 ]
Hassager, Ole [5 ]
Cestari, Ismar N. [1 ]
机构
[1] Univ Sao Paulo, Sch Med, Heart Inst InCor, Bioengn Div, Sao Paulo, Brazil
[2] Univ Sao Paulo, Sch Med, Heart Inst InCor, Dept Thorac & Cardiovasc Surg, Sao Paulo, Brazil
[3] Tech Univ Denmark, MSc Eng Program, Copenhagen, Denmark
[4] Univ Copenhagen, DK-1168 Copenhagen, Denmark
[5] Tech Univ Denmark, Danish Polymer Ctr, Dept Chem & Biochem Engn, DK-2800 Lyngby, Denmark
关键词
tissue engineering; heart valves; bioreactor; ventricular assist device; Windkessel; cardiomimetic approach; PULSATILE BIOREACTOR; STEM-CELLS; DESIGN; POLYURETHANE; CATHETERS; CULTURE; ETHANOL; SYSTEM;
D O I
10.1002/term.315
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The 'biomimetic' approach to tissue engineering usually involves the use of a bioreactor mimicking physiological parameters whilst supplying nutrients to the developing tissue. Here we present a new heart valve bioreactor, having as its centrepiece a ventricular assist device (VAD), which exposes the cell-scaffold constructs to a wider array of mechanical forces. The pump of the VAD has two chambers: a blood and a pneumatic chamber, separated by an elastic membrane. Pulsatile air-pressure is generated by a piston-type actuator and delivered to the pneumatic chamber, ejecting the fluid in the blood chamber. Subsequently, applied vacuum to the pneumatic chamber causes the blood chamber to fill. A mechanical heart valve was placed in the VAD's inflow position. The tissue engineered (TE) valve was placed in the outflow position. The VAD was coupled in series with a Windkessel compliance chamber, variable throttle and reservoir, connected by silicone tubings. The reservoir sat on an elevated platform, allowing adjustment of ventricular preload between 0 and 11 mmHg. To allow for sterile gaseous exchange between the circuit interior and exterior, a 0.2 mu m filter was placed at the reservoir. Pressure and flow were registered downstream of the TE valve. The circuit was filled with culture medium and fitted in a standard 5% CO2 incubator set at 37 degrees C. Pressure and flow waveforms were similar to those obtained under physiological conditions for the pulmonary circulation. The 'cardiomimetic' approach presented here represents a new perspective to conventional biomimetic approaches in TE, with potential advantages. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:292 / 300
页数:9
相关论文
共 50 条
  • [1] A new approach to heart valve tissue engineering
    Flameng, W
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 95 : S55 - S56
  • [2] A new approach to heart valve tissue engineering.
    Willem, F
    [J]. ACTA CARDIOLOGICA, 2006, 61 (02) : 205 - 206
  • [3] Tissue Engineering of Human Heart Valve Leaflets: A Novel Bioreactor for a Strain-Based Conditioning Approach
    Anita Mol
    Niels J. B. Driessen
    Marcel C. M. Rutten
    Simon P. Hoerstrup
    Carlijn V. C. Bouten
    Frank P. T. Baaijens
    [J]. Annals of Biomedical Engineering, 2005, 33 : 1778 - 1788
  • [4] Tissue engineering of human heart valve leaflets: A novel bioreactor for a strain-based conditioning approach
    Mol, A
    Driessen, NJB
    Rutten, MCM
    Hoerstrup, SP
    Bouten, CVC
    Baaijens, FPT
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (12) : 1778 - 1788
  • [5] Ventricular assist device use in single ventricle congenital heart disease
    Carlo, Waldemar F.
    Villa, Chet R.
    Lal, Ashwin K.
    Morales, David L.
    [J]. PEDIATRIC TRANSPLANTATION, 2017, 21 (07)
  • [6] Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device
    Lee, Hwansung
    Akagawa, Eiki
    Hornma, Akihiko
    Tsukiya, Tomonori
    Tatsumi, Eisuke
    Taenaka, Yoshiyuki
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2007, 10 (03) : 181 - 185
  • [7] Transcatheter Heart Valve Thrombosis in a Patient With a Left Ventricular Assist Device
    Rudisill, Kristyn G.
    Smallfield, Melissa C.
    Shah, Keyur B.
    Quader, Mohammed A.
    Bhardwaj, Hem L.
    Gertz, Zachary M.
    [J]. CIRCULATION-HEART FAILURE, 2020, 13 (09) : E007112
  • [8] Characteristics of mechanical heart valve cavitation in a pneumatic ventricular assist device
    Lee, Hwansung
    Taenaka, Yoshiyuki
    [J]. ARTIFICIAL ORGANS, 2008, 32 (06) : 453 - 460
  • [9] Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device
    Hwansung Lee
    Eiki Akagawa
    Akihiko Homma
    Tomonori Tsukiya
    Eisuke Tatsumi
    Yoshiyuki Taenaka
    [J]. Journal of Artificial Organs, 2007, 10 : 181 - 185
  • [10] Mechanical heart valve performance in a pulsatile pediatric ventricular assist device
    Zapanta, Conrad M.
    Dourte, Leann M.
    Doxtater, Bradley J.
    Lukic, Branka
    Weiss, William J.
    [J]. ASAIO JOURNAL, 2007, 53 (01) : 87 - 96