A new approach to heart valve tissue engineering: mimicking the heart ventricle with a ventricular assist device in a novel bioreactor

被引:5
|
作者
Kaasi, Andreas [1 ,3 ,4 ,5 ]
Cestari, Idagene A. [1 ]
Stolf, Noedir A. G. [2 ]
Leirner, Adolfo A. [1 ]
Hassager, Ole [5 ]
Cestari, Ismar N. [1 ]
机构
[1] Univ Sao Paulo, Sch Med, Heart Inst InCor, Bioengn Div, Sao Paulo, Brazil
[2] Univ Sao Paulo, Sch Med, Heart Inst InCor, Dept Thorac & Cardiovasc Surg, Sao Paulo, Brazil
[3] Tech Univ Denmark, MSc Eng Program, Copenhagen, Denmark
[4] Univ Copenhagen, DK-1168 Copenhagen, Denmark
[5] Tech Univ Denmark, Danish Polymer Ctr, Dept Chem & Biochem Engn, DK-2800 Lyngby, Denmark
关键词
tissue engineering; heart valves; bioreactor; ventricular assist device; Windkessel; cardiomimetic approach; PULSATILE BIOREACTOR; STEM-CELLS; DESIGN; POLYURETHANE; CATHETERS; CULTURE; ETHANOL; SYSTEM;
D O I
10.1002/term.315
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The 'biomimetic' approach to tissue engineering usually involves the use of a bioreactor mimicking physiological parameters whilst supplying nutrients to the developing tissue. Here we present a new heart valve bioreactor, having as its centrepiece a ventricular assist device (VAD), which exposes the cell-scaffold constructs to a wider array of mechanical forces. The pump of the VAD has two chambers: a blood and a pneumatic chamber, separated by an elastic membrane. Pulsatile air-pressure is generated by a piston-type actuator and delivered to the pneumatic chamber, ejecting the fluid in the blood chamber. Subsequently, applied vacuum to the pneumatic chamber causes the blood chamber to fill. A mechanical heart valve was placed in the VAD's inflow position. The tissue engineered (TE) valve was placed in the outflow position. The VAD was coupled in series with a Windkessel compliance chamber, variable throttle and reservoir, connected by silicone tubings. The reservoir sat on an elevated platform, allowing adjustment of ventricular preload between 0 and 11 mmHg. To allow for sterile gaseous exchange between the circuit interior and exterior, a 0.2 mu m filter was placed at the reservoir. Pressure and flow were registered downstream of the TE valve. The circuit was filled with culture medium and fitted in a standard 5% CO2 incubator set at 37 degrees C. Pressure and flow waveforms were similar to those obtained under physiological conditions for the pulmonary circulation. The 'cardiomimetic' approach presented here represents a new perspective to conventional biomimetic approaches in TE, with potential advantages. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:292 / 300
页数:9
相关论文
共 50 条
  • [41] Design of a new pulsatile bioreactor for tissue engineered aortic heart valve formation
    Dumont, K
    Yperman, J
    Verbeken, E
    Segers, P
    Meuris, B
    Vandenberghe, S
    Flameng, W
    Verdonck, PR
    [J]. ARTIFICIAL ORGANS, 2002, 26 (08) : 710 - 714
  • [42] Shear Stress Quantification in Tissue Engineering Bioreactor Heart Valves: A Computational Approach
    Dave, Raj
    Luraghi, Giulia
    Sierad, Leslie
    Migliavacca, Francesco
    Kung, Ethan
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (03)
  • [43] Heart transplant and left ventricular assist device costs
    Bostic, RR
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (11): : 1997 - 1998
  • [44] Diaphragmatic implantation of the Heart Ware ventricular assist device
    Gregoric, Igor D.
    Cohn, William E.
    Frazier, O. H.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (04): : 467 - 470
  • [45] Ventricular Assist Device as a Bridge to Heart Transplantation in Adults
    Engin, C.
    Ayik, F.
    Oguz, E.
    Eygi, B.
    Yagdi, T.
    Karakula, S.
    Ozbaran, M.
    [J]. TRANSPLANTATION PROCEEDINGS, 2011, 43 (03) : 927 - 930
  • [46] Ventricular Assist Device in Patients With Prosthetic Heart Valves
    Mokashi, Suyog A.
    Schmitto, Jan D.
    Lee, Lawrence S.
    Rawn, James D.
    Bolman, R. Morton, III
    Shekar, Prem S.
    Couper, Gregory S.
    Chen, Frederick Y.
    [J]. ARTIFICIAL ORGANS, 2010, 34 (11) : 1030 - 1034
  • [47] Left Ventricular Assist Device Followed by Heart Transplantation
    Biselli, Bruno
    Ayub-Ferreira, Silvia Moreira
    Avila, Monica Samuel
    Gaiotto, Fabio Antonio
    Jatene, Fabio Biscegli
    Bocchi, Edimar Alcides
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2015, 104 (03) : E22 - E24
  • [48] Heart transplant and left ventricular assist device costs
    DiGiorgi, PL
    Reel, MS
    Thornton, B
    Burton, E
    Naka, Y
    Oz, MC
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02): : 200 - 204
  • [49] Left ventricular assist device in heart failure - Reply
    Dang, NC
    Naka, Y
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05): : 1212 - 1212
  • [50] Effect of Systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: Using a monoleaflet valve
    Lee, Hwansung
    Tatsumi, Eisuke
    Taenaka, Yoshiyuki
    [J]. ASAIO JOURNAL, 2008, 54 (01) : 25 - 30