Neurospora sitophila in indoor environment of buildings

被引:2
|
作者
Vojtkova, H. [1 ]
Simonovicova, A. [2 ]
Cernansky, S. [3 ]
机构
[1] VSB Tech Univ Ostrava, Fac Min & Geol, Dept Environm Engn, 17 Listopadu 2172-15, Ostrava 70800, Czech Republic
[2] Comenius Univ, Fac Nat Sci, Dept Soil Sci, Ilkovicova 6, Bratislava 84215, Slovakia
[3] Comenius Univ, Fac Nat Sci, Dept Environm Ecol, Ilkovicova 6, Bratislava 84215, Slovakia
来源
ADVANCES IN ENVIRONMENTAL ENGINEERING (AEE2019) | 2020年 / 444卷
关键词
CHRYSONILIA-SITOPHILA; DIAGNOSIS; PNEUMONITIS; CRASSA;
D O I
10.1088/1755-1315/444/1/012055
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Neurospora sitophila is a microscopic filamentous fungus of the Ascomycete taxon that rapidly expands in the environment. Although the fungus has been recorded primarily as a known laboratory contaminant, this contribution presents evidence of its frequent occurrence in indoor environment of offices at the university, especially in places where a coffee maker was part of the equipment. A total of 50 smears were made from the environment of the University of VSB - TU Ostrava from various parts of the fixtures. It was found that spores and fragments of N. sitophila mycelia are an active part of the building air using the BIOLOG identification system. Although no direct evidence has yet been obtained that N. sitophila is the causative agent of human disease or infection, the presence of this fungus in the environment should be regarded as a risk factor for human health. Exposure to fungal spores and fragments of mycelia in the indoor environment of buildings can cause hypersensitivity known to be an influencing factor in allergic reactions and asthma.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Summer investigation on indoor environment of residential buildings in Beijing
    Yoshino, H
    Zhang, QY
    Yoshino, Y
    Shigeno, T
    Li, ZH
    Kumagai, K
    Ni, YY
    Yanagisawa, Y
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 477 - 485
  • [42] Indoor air environment of residential buildings in Dalian, China
    Zhao, Y
    Chen, B
    Guo, YL
    Peng, FF
    Zhao, JL
    ENERGY AND BUILDINGS, 2004, 36 (12) : 1235 - 1239
  • [43] Hygrothermal Analysis of Indoor Environment of Residential Prefabricated Buildings
    Kraus, Michal
    WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM - WMCAUS, 2017, 245
  • [44] Perceived importance of the quality of the indoor environment in commercial buildings
    Lai, Joseph H. K.
    Yik, Francis W. H.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (04) : 311 - 321
  • [45] Influence of the Indoor Environment Quality on the Market Value of the Buildings
    Pasek, Jan
    ENVIBUILD 2014, 2014, 1041 : 358 - 361
  • [46] Advanced Technologies on Indoor Environment Quality in Sustainable Buildings
    Sheng, Ying
    SUSTAINABILITY, 2024, 16 (16)
  • [47] INDOOR ENVIRONMENT, LIGHTING CONDITIONS AND PRODUCTIVITY IN THE EDUCATIONAL BUILDINGS
    Krawczyk, Natalia
    Debska, Luiza
    CIVIL AND ENVIRONMENTAL ENGINEERING, 2022, 18 (02) : 581 - 588
  • [48] Occupancy and Indoor Environment Quality Sensing for Smart Buildings
    Han, Zhenyu
    Gao, Robert X.
    Fan, Zhaoyan
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 882 - 887
  • [49] PRODUCTION OF CELLULOLYTIC ENZYMES BY NEUROSPORA-SITOPHILA GROWN ON CELLULOSIC MATERIALS
    OGUNTIMEIN, G
    VLACH, D
    MOOYOUNG, M
    BIORESOURCE TECHNOLOGY, 1992, 39 (03) : 277 - 283
  • [50] Analysis of indoor humidity environment in Chinese residential buildings
    Zhang, Huibo
    Yoshino, Hiroshi
    BUILDING AND ENVIRONMENT, 2010, 45 (10) : 2132 - 2140