Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)

被引:20
|
作者
Elshenawy, Enas A. [1 ]
Alam-Eldein, Ahmed M. [2 ]
Abd Elfatah, Fadel A. [2 ]
机构
[1] Tanta Univ, Fac Dent, Dent Biomat Dept, Tanta, Egypt
[2] Tanta Univ, Fac Dent, Prosthodont Dept, Tanta, Egypt
关键词
Direct technique; Indirect technique; Internal connection implant; Splinting procedure; SPLINTING MATERIALS; DEFINITIVE CASTS; CONNECTION; PROSTHESES; SYSTEM; TRAYS;
D O I
10.1186/s40729-018-0118-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. This study was designed to compare the dimensional accuracy of casts obtained from three impression techniques for three definitive lower casts with implants at different angulations. Methods: Three Osseolink implants were placed in three reference models with different angles (parallel, 15 degrees and 30 degrees). Impressions of each model were made with three techniques (n = 10 per group): indirect, unsplinted direct, and acrylic resin-splinted direct technique. Impressions were poured with type IV dental stone. Inter-implant distances were measured for casts using a coordinate measuring machine, and the deviations from the reference models (Delta r) were calculated. Data were analyzed using one-way ANOVA followed by post hoc tests to detect significance between groups (alpha = 0.05). Results: This study showed that the deviations in micrometers from the reference model were the least for acrylic resin-splinted direct technique (Delta r1 = 49.96, Delta r2 = 50.36) versus indirect (Delta r1 = 93.8, Delta r2 = 90.9) and unsplinted direct techniques ((Delta r1 = 67.07, Delta r2 = 68.66) in 30 degrees angulated implant situation (p value < 0.0001* for both Delta r1 and Delta r2). In 15 degrees angulated implants, both the acrylic resin-splinted direct (Delta r1 = 44.64, Delta r2 = 45.58) and unsplinted direct techniques (Delta r1 = 47.39, Delta r2 = 55.28) were more accurate than indirect technique (Delta r1 = 64.8, Delta r2 = 68.3) (p value < 0.0001* for both Delta r1 and Delta r2). While in parallel condition, no difference was found between all three techniques (p value = 0.085, 0.056 for Delta r1 and Delta r2, respectively). Conclusions: The impression technique affected the accuracy of definitive casts. The acrylic resin splinted direct technique produced the most accurate casts, followed by direct unsplinted and indirect techniques. Furthermore, implant angulation affected the impression accuracy. When implant angulation increased from parallel implants to 30 degrees, the forces of deformation increased, which resulted in increased distortion.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comparative Evaluation of the Rigidity and Accuracy of Different Elastomeric Impression Materials with Open Tray Implant Level Impression Technique-An In vitro Study
    Aidasani, Ashwin N.
    Jain, Shailesh
    Hassan, Sahba
    Sharma, Anu
    Shanthi, C.
    Fere, Sandeep
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1262 - S1265
  • [22] In vitro evaluation of surface cleaning methods in two different implant defect angulations: a pilot study
    Ozkan Karaca, Ebru
    Tunar, Ogul Leman
    [J]. BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2021, 35 (01) : 560 - 566
  • [23] ACCURACY OF IMPRESSION TECHNIQUES IN IMPLANT DENTISTRY
    Alrumi, Bader Abdullah
    al Yami, Ibrahim Mohammed
    Alghamdi, Randah Abdulrhman
    Aldajani, Ali Mohammed
    Alhelaly, Hussein Mohammed
    Mohammed, Abdulrahman Thabet
    Abotaleb, Mohannd Talebalrahman
    Aljuaid, Mohammed Mbearak
    Alotaibi, Jamal Mousa
    Alelyani, Mohammed Dakhil
    [J]. INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (01): : 1396 - 1402
  • [24] Accuracy of Implant Impressions with Different Impression Coping Types and Shapes
    Rashidan, Nayereh
    Alikhasi, Marzieh
    Samadizadeh, Samad
    Beyabanaki, Elahe
    Kharazifard, Mohammad Javad
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (02) : 218 - 225
  • [25] Accuracy of Different Elastomeric Impression Materials Using Dual Arch Impression Trays: An In Vitro Study
    Duseja, Sareen
    Shah, Dipti
    Vaishnav, Kalpesh
    Duseja, Shilpa
    Kumar, Santosh
    Desai, Khushboo
    [J]. ADVANCES IN HUMAN BIOLOGY, 2014, 4 (02) : 3 - 8
  • [26] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    [J]. JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 (06) : 412 - 415
  • [27] Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection
    Wenz, Hans-Juergen
    Hertrampf, Katrin
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (01) : 39 - 47
  • [28] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    [J]. JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S412 - S415
  • [29] Implant Impression Techniques using Different Materials and Methods: A Review
    Yasar, Muhammed Necati
    Cetinsahin, Cem
    Bayar, Omer
    Ozer, Hasan Yildrim
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (02) : ZE12 - ZE17
  • [30] Effect of 2 Impression Techniques on the Dimensional Accuracy of Working Implant Prosthesis Models: An In Vitro Study
    Calesini, Gaetano
    Zarone, Fernando
    Sorrentino, Roberto
    Micarelli, Costanza
    Fabianelli, Andrea
    Papacchini, Federica
    Gherlone, Enrico