In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables

被引:46
|
作者
Hitchon, PW
Brenton, MD
Black, AG
From, A
Harrod, JS
Barry, C
Serhan, H
Torner, JC
机构
[1] Univ Iowa, Roy J & Lucille A Carver Coll Med, Coll Publ Hlth, Dept Neurosurg, Iowa City, IA USA
[2] Univ Iowa, Roy J & Lucille A Carver Coll Med, Coll Publ Hlth, Dept Biomed Engn, Iowa City, IA USA
[3] Univ Iowa, Roy J & Lucille A Carver Coll Med, Coll Publ Hlth, Dept Epidemiol, Iowa City, IA USA
[4] Vet Adm Med Ctr, Iowa City, IA USA
关键词
pedicle screw; sublaminar hook; sublaminar cable; bone mineral density; biomechanical study;
D O I
10.3171/spi.2003.99.1.0104
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Three types of posterior thoracolumbar implants are in use today: pedicle screws, sublaminar titanium cables, and sublaminar hooks. The authors conducted a biomechanical comparison of these three implants in human cadaveric spines. Methods. Spine specimens (T5-12) were harvested, radiographically assessed for fractures or metastases, and their bone mineral density (BMD) was measured. Individual vertebrae were disarticulated and fitted with either pedicle screws, sublaminar cables, or bilateral claw hooks. The longitudinal component of each construct consisted of bilateral 10-cm rods connected with two cross-connectors. The vertebral body was embedded in cement, and the rods were affixed to a ball-and-socket apparatus for the application of a distraction force. The authors analyzed 1) 20 vertebrae implanted with screws; 2) 20 with hooks, and 3) 20 with cables. The maximum pullout (MPO) forces prior to failure (mean +/- standard deviation) for the screw, hook, and cable implants were 972 +/- 330, 802 +/- 356, and 654 +/- 248 N, respectively (p = 0.0375). Cables allowed significantly greater displacement (6.80 +/- 3.95 mm) prior to reaching the MPO force than hooks (3.73 +/- 1.42 mm) and screws (4.42 +/- 2.15 mm [p = 0.0108]). Eleven screw-implanted vertebrae failed because of screw pullout. All hook-and-cable-implanted vertebrae failed because of pedicle, middle column, or laminar fracture. Conclusions. These findings suggest that screws possess the greatest pullout strength of the three fixation systems. Sublaminar cables are the least rigid of the three. When screw failure occurred, the mechanism was generally screw backout, without vertebral fractures.
引用
收藏
页码:104 / 109
页数:6
相关论文
共 50 条
  • [31] Cervical pedicle screws versus lateral mass screws - Anatomic feasibility and biomechanical comparison
    Jones, EL
    Heller, JG
    Silcox, DH
    Hutton, WC
    SPINE, 1997, 22 (09) : 977 - 982
  • [32] Biomechanical comparison of inside–outside screws, cables, and regular screws, using a sawbone model
    Yusuf Sukru Caglar
    Fuat Torun
    Thomas Glenn Pait
    William Hogue
    Melih Bozkurt
    Serdar Özgen
    Neurosurgical Review, 2005, 28 : 53 - 58
  • [33] The Influence of Proximal Anchors on the Risk of Proximal Junctional Fracture in the Osteoporotic Spine Biomechanical Comparison Between Pedicle Screws and Transverse Process Hooks
    Mac-Thiong, Jean-Marc
    Levasseur, Annie
    Parent, Stefan
    Petit, Yvan
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (02): : E49 - E54
  • [34] The effectiveness of short hybrid stabilization with sublaminar bands and transpedicular screws in the treatment of thoracolumbar fractures
    Brembilla, Carlo
    Fanti, Andrea
    Rampini, Angela Dele
    Dorelli, Gianluigi
    Sicignano, Angelo Mirco
    Cracchiolo, Giorgio
    Bernucci, Claudio
    JOURNAL OF NEUROSURGICAL SCIENCES, 2022, : 412 - 421
  • [35] Volumetric spinal canal intrusion - A comparison between thoracic pedicle screws and thoracic hooks
    Polly, DW
    Potter, BK
    Kuklo, T
    Young, S
    Johnson, C
    Klemme, WR
    SPINE, 2004, 29 (01) : 63 - 69
  • [36] Effect of the Degree of Osteoporosis on the Biomechanical Anchoring Strength of the Sacral Pedicle Screws An In Vitro Comparison Between Unaugmented Bicortical Screws and Polymethylmethacrylate Augmented Unicortical Screws
    Zhuang, Xin-Ming
    Yu, Bin-Sheng
    Zheng, Zhao-Min
    Zhang, Jia-Fang
    Lu, William W.
    SPINE, 2010, 35 (19) : E925 - E931
  • [37] Cervical spine pedicle screws - A biomechanical comparison of two insertion techniques
    Kowalski, JM
    Ludwig, SC
    Hutton, WC
    Heller, JG
    SPINE, 2000, 25 (22) : 2865 - 2867
  • [38] A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions
    Bostan, Bora
    Esenkaya, Irfan
    Gunes, Taner
    Erdem, Mehmet
    Asci, Murat
    Kelestemur, M. Halidun
    Sen, Cengiz
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (03) : 272 - 276
  • [39] Attenuation of Proximal Junctional Kyphosis Using Sublaminar Polyester Tension Bands: A Biomechanical Study
    Cho, Samuel K.
    Caridi, John
    Kim, Jun S.
    Cheung, Zoe B.
    Gandhi, Anup
    Inzana, Jason
    WORLD NEUROSURGERY, 2018, 120 : E1136 - E1142
  • [40] Biomechanical comparison of inside-outside screws, cables, and regular screws, using a sawbone model
    Caglar, YS
    Torun, F
    Pait, TG
    Hogue, W
    Bozkurt, M
    Özgen, S
    NEUROSURGICAL REVIEW, 2005, 28 (01) : 53 - 58