In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables

被引:46
|
作者
Hitchon, PW
Brenton, MD
Black, AG
From, A
Harrod, JS
Barry, C
Serhan, H
Torner, JC
机构
[1] Univ Iowa, Roy J & Lucille A Carver Coll Med, Coll Publ Hlth, Dept Neurosurg, Iowa City, IA USA
[2] Univ Iowa, Roy J & Lucille A Carver Coll Med, Coll Publ Hlth, Dept Biomed Engn, Iowa City, IA USA
[3] Univ Iowa, Roy J & Lucille A Carver Coll Med, Coll Publ Hlth, Dept Epidemiol, Iowa City, IA USA
[4] Vet Adm Med Ctr, Iowa City, IA USA
关键词
pedicle screw; sublaminar hook; sublaminar cable; bone mineral density; biomechanical study;
D O I
10.3171/spi.2003.99.1.0104
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Three types of posterior thoracolumbar implants are in use today: pedicle screws, sublaminar titanium cables, and sublaminar hooks. The authors conducted a biomechanical comparison of these three implants in human cadaveric spines. Methods. Spine specimens (T5-12) were harvested, radiographically assessed for fractures or metastases, and their bone mineral density (BMD) was measured. Individual vertebrae were disarticulated and fitted with either pedicle screws, sublaminar cables, or bilateral claw hooks. The longitudinal component of each construct consisted of bilateral 10-cm rods connected with two cross-connectors. The vertebral body was embedded in cement, and the rods were affixed to a ball-and-socket apparatus for the application of a distraction force. The authors analyzed 1) 20 vertebrae implanted with screws; 2) 20 with hooks, and 3) 20 with cables. The maximum pullout (MPO) forces prior to failure (mean +/- standard deviation) for the screw, hook, and cable implants were 972 +/- 330, 802 +/- 356, and 654 +/- 248 N, respectively (p = 0.0375). Cables allowed significantly greater displacement (6.80 +/- 3.95 mm) prior to reaching the MPO force than hooks (3.73 +/- 1.42 mm) and screws (4.42 +/- 2.15 mm [p = 0.0108]). Eleven screw-implanted vertebrae failed because of screw pullout. All hook-and-cable-implanted vertebrae failed because of pedicle, middle column, or laminar fracture. Conclusions. These findings suggest that screws possess the greatest pullout strength of the three fixation systems. Sublaminar cables are the least rigid of the three. When screw failure occurred, the mechanism was generally screw backout, without vertebral fractures.
引用
收藏
页码:104 / 109
页数:6
相关论文
共 50 条
  • [1] Sublaminar fixation versus hooks and pedicle screws in scoliosis surgery for Marfan syndrome
    Rava, Alessandro
    Dema, Eugenio
    Palmisani, Matteo
    Palmisani, Rosa
    Cervellati, Stefano
    Girardo, Massimo
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2020, 11 (01): : 26 - 30
  • [2] Hooks Versus Pedicle Screws at the Upper Instrumented Level An In Vitro Biomechanical Comparison
    Colantonio, Donald F.
    Le, Anthony H.
    Pisano, Alfred J.
    Chung, Joon M.
    Wagner, Scott C.
    Fredericks, Donald R.
    Roach, William B.
    Schlaff, Cody
    Dill, Andrew
    Mauntel, Timothy C.
    Hendershot, Brad D.
    Helgeson, Melvin D.
    SPINE, 2023, 48 (07) : E94 - E100
  • [3] Comparison of Pedicle Screws Versus Hybrid Fixation With Sublaminar Polyester Bands in the Treatment of Neuromuscular Scoliosis
    Kilicaslan, Omer Faruk
    Akalin, Serdar
    Tokgoz, Mehmet Ali
    Cetin, Hakan
    Etli, Ibrahim
    WORLD NEUROSURGERY, 2021, 151 : E672 - E681
  • [4] The biomechanical analysis of sublaminar wires and cables using Luque segmental spinal instrumentation
    Parsons, JR
    Chokshi, BV
    Lee, CK
    Gundlapalli, RV
    Stamer, D
    SPINE, 1997, 22 (03) : 267 - 273
  • [5] OSTEOPOROTIC VERTEBRAL COMPRESSION FRACTURE: USE OF SUBLAMINAR MERSILENE TAPE AUGMENTED PEDICLE SCREWS
    Kakadiya, G.
    Chaudhary, K.
    OSTEOPOROSIS INTERNATIONAL, 2021, 32 (SUPPL 1) : S119 - S119
  • [6] Deformity correction in thoracic adolescent idiopathic scoliosis A COMPARISON OF POSTEROMEDIAL TRANSLATION USING SUBLAMINAR BANDS AND CANTILEVER WITH PEDICLE SCREWS
    Pesenti, S.
    Lafage, R.
    Henry, B.
    Kim, H. J.
    Bolzinger, M.
    Elysee, J.
    Cunningham, M.
    Choufani, E.
    Lafage, V
    Blanco, J.
    Jouve, J-L
    Widmann, R.
    BONE & JOINT JOURNAL, 2020, 102B (03): : 376 - 382
  • [7] Selective thoracolumbar instrumentation with pedicle screws and sublaminar bands (universal clamps) in adolescent idiopathic scoliosis
    Claudio Lamartina
    Riccardo Cecchinato
    European Spine Journal, 2011, 20 : 2286 - 2287
  • [8] A biomechanical analysis of sublaminar and subtransverse process fixation using metal wires and polyethylene cables
    Fujita, Masaru
    Diab, Mohammad
    Xu, Zheng
    Puttlitz, Christian M.
    SPINE, 2006, 31 (19) : 2202 - 2208
  • [9] THE USE OF SUBLAMINAR CABLES TO REPLACE LUQUE WIRES
    SONGER, MN
    SPENCER, DL
    MEYER, PR
    JAYARAMAN, G
    SPINE, 1991, 16 (08) : S418 - S421
  • [10] Selective thoracolumbar instrumentation with pedicle screws and sublaminar bands (universal clamps) in adolescent idiopathic scoliosis
    Lamartina, Claudio
    Cecchinato, Riccardo
    EUROPEAN SPINE JOURNAL, 2011, 20 (12) : 2286 - 2287