Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry

被引:69
|
作者
Turpeinen, Ursula [1 ]
Hamalainen, Esa [1 ,2 ]
Stenman, Ulf-Hakan [2 ]
机构
[1] HUSLAB, Lab Womens Clin, Helsinki 00029, Finland
[2] Univ Helsinki, Dept Clin Chem, SF-00100 Helsinki, Finland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 862卷 / 1-2期
关键词
serum aldosterone; LC-MS/MS; ESI; Electrospray ionization mass spectrometry; API; 3000; RIA;
D O I
10.1016/j.jchromb.2007.11.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of serum aldosterone is clinically important in the diagnosis of hypertension.)While isotope dilution gas chromatography-mass spectrometry (ID-GC-MS) provides reliable results, it requires derivatization and is lengthy and time-consuming. Detection by liquid chromatography-mass spectrometry (LC-MS) is a potentially superior method. The analysis utilizes 0.5 mL of serum. The samples were extracted with dichloromethane-ether. The extract was evaporated to dryness and aldosterone was analyzed by LC-MS/MS operating in the negative mode ESI after separation on a reversed-phase column. Aldosterone was also measured by RIA. The calibration curves for analysis of serum aldosterone exhibited consistent linearity and reproducibility in the range of 60-3000 pmol/L. Interassay CVs were 4.3-7.5% at aldosterone concentrations of 97-993 pmol/L. The lower limit of quantitation (LOQ) was 30 pmol/L (signal to noise ratio = 10). The mean recovery of the analyte added to serum ranged from 95 to 102%. The regression equation by LC-MS/MS (x) and RIA (y) method was: y = 1.33x + 185 (r = 0.95; n = 124). Sensitivity and specificity of the LC-MS/MS method for serum aldosterone offer advantages over GC-MS by eliminating derivatization. The novel method is rapid, reliable and simple to perform with a routine LC-MS/MS spectrometer. The sensitivity is adequate for patient samples. Aldosterone concentrations reported by nonextraction RIA were consistently higher than those produced by LC-MS/MS. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 50 条
  • [41] Determination of streptomycin residues in honey by liquid chromatography-tandem mass spectrometry
    Granja, Rodrigo H. M. M.
    Montes Nino, Alfredo M.
    Zucchetti, Roberto A. M.
    Montes Nino, Rosario E.
    Patel, Raj
    Salerno, Alessandro G.
    ANALYTICA CHIMICA ACTA, 2009, 637 (1-2) : 64 - 67
  • [42] Determination of β-agonists in liver and retina by liquid chromatography-tandem mass spectrometry
    Fesser, Adrian C.E.
    Dickson, Leslie C.
    Macneil, James D.
    Patterson, John R.
    Lee, Stephen
    Gedir, Ronald
    Journal of AOAC International, 1600, 88 (01): : 61 - 69
  • [43] Determination of stanozolol in hair using liquid chromatography-tandem mass spectrometry
    Xiang Ping
    Shen Min
    Shen Baohua
    Yan Hui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (04) : 469 - 472
  • [44] Determination of flunixin and ketoprofen in milk by liquid chromatography-tandem mass spectrometry
    Daeseleire, E
    Mortier, L
    De Ruyck, H
    Geerts, N
    ANALYTICA CHIMICA ACTA, 2003, 488 (01) : 25 - 34
  • [45] Determination of Immunodepressants and Combined Drugs by Liquid Chromatography-Tandem Mass Spectrometry
    Li Peng-Fei
    Wang Yan
    Zhang Zheng
    Tong Wei-Hang
    Wu Hua
    Ma Ping
    Wang Jing
    Liu Li-Hong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (10) : 1573 - 1578
  • [46] Determination of dioscin in rat plasma by liquid chromatography-tandem mass spectrometry
    Li, K
    Wang, YW
    Gu, JK
    Chen, XY
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (02): : 271 - 275
  • [47] Determination of silodosin in human plasma by liquid chromatography-tandem mass spectrometry
    Zhao, Xia
    Liu, Yuwang
    Xu, Junyu
    Zhang, Dan
    Zhou, Ying
    Gu, Jingkai
    Cui, Yimin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3724 - 3728
  • [48] Determination of typhaneoside in rat plasma by liquid chromatography-tandem mass spectrometry
    Chen, Peidong
    Liu, Shijia
    Dai, Guoliang
    Xie, Liyan
    Xu, Jie
    Zhou, Ling
    Ju, Wenzheng
    Ding, Anwei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 636 - 639
  • [49] Determination of cyclosporine in saliva using liquid chromatography-tandem mass spectrometry
    Mendonza, A
    Gohh, R
    Akhlaghi, F
    THERAPEUTIC DRUG MONITORING, 2004, 26 (05) : 569 - 575
  • [50] Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry
    Lee, HW
    Ji, HY
    Kim, HH
    Cho, HY
    Lee, YB
    Lee, HS
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (02): : 395 - 400