Understanding the effect of scan spans on the accuracy of intraoral and desktop scanners

被引:30
|
作者
Chen, Yuming [1 ]
Zhai, Zhihao [1 ]
Watanabe, Shota [1 ]
Nakano, Tamaki [1 ]
Ishigaki, Shoichi [1 ]
机构
[1] Osaka Univ, Grad Sch Dent, Dept Fixed Prosthodont, 1-8 Yamadaoka, Suita, Osaka 5650871, Japan
来源
JOURNAL OF DENTISTRY | 2022年 / 124卷
关键词
Intraoral scanners; Desktop scanners; Trueness; Precision; Digital dentistry; AMBIENT LIGHT; IMPRESSIONS; TIME;
D O I
10.1016/j.jdent.2022.104220
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to measure and compare the accuracy (trueness and precision) of intraoral scanners and desktop scanners when scanning different spans. Methods: Three plaster models representing different spans (full arch, half arch, and three teeth) were obtained from conventional silicone impressions of a maxillary typodont and used as the scanning objects. An industrial scanner (ATOS III Triple Scan) was used to scan the three plaster models to obtain reference digital models. The plaster models were then scanned using two intraoral scanners (Trios 3 and Primescan) and two desktop scanners (LS3 and D2000) to obtain test digital models. The reference and test models were imported into professional reverse engineering software for processing and analysis. The root mean square value indicated differences between the reference and test models. Two-way ANOVA and Bonferroni multiple comparison tests were used for statistical analysis. Results: Two-way ANOVA tests revealed significant differences in trueness and precision for different scan spans (p < 0.001) and different scanners (p < 0.001), which indicates that the scanner types and scan spans affect the accuracy of the scanner. There was no significant difference in the accuracy of the D2000 at three different scan spans (trueness: 23.82 +/- 0.22 mu m, 21.53 +/- 0.18 mu m, and 21.02 +/- 0.27 mu m respectively; precision: 7.86 +/- 0.83 mu m, 7.87 +/- 1.11 mu m, and 7.82 +/- 0.84 mu m respectively). For the LS3 and the two intraoral scanners, the accuracy of the full arch scan (LS 3, trueness: 33.35 +/- 0.47 mu m, precision:15.36 +/- 3.10 mu m; Trios 3, trueness: 46.92 +/- 9.23 mu m, precision:20.79 +/- 3.08 mu m; Primescan, trueness: 28.73 +/- 0.77 mu m, precision:15.74 +/- 2.45 mu m) was significantly lower than that of the half arch (LS 3, trueness: 27.27 +/- 0.43 mu m, precision:5.62 +/- 0.88 mu m; trios 3, Trueness: 22.29 +/- 1.50 mu m, precision:14.12 +/- 2.25 mu m; Primescan, trueness: 18.91 +/- 0.70 mu m, precision:7.94 +/- 1.09 mu m) and three teeth scans (LS 3, trueness: 24.68 +/- 0.36 mu m, precision:5.29 +/- 0.62 mu m; Trios 3, trueness: 16.92 +/- 0.78 mu m, precision:11.95 +/- 2.22 mu m; Primescan, trueness: 15.79 +/- 0.65 mu m, precision:7.68 +/- 0.62 mu m). Conclusions: The scan span affected the accuracy of the intraoral scanners, but not necessarily the accuracy of the desktop scanners.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Investigation of accuracy and reproducibility of abutment position by intraoral scanners
    Fukazawa, Shota
    Odaira, Chikayuki
    Kondo, Hisatomo
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (04) : 450 - 459
  • [22] Accuracy of five intraoral scanners compared to indirect digitalization
    Gueth, Jan-Frederik
    Runkel, Cornelius
    Beuer, Florian
    Stimmelmayr, Michael
    Edelhoff, Daniel
    Keul, Christine
    [J]. CLINICAL ORAL INVESTIGATIONS, 2017, 21 (05) : 1445 - 1455
  • [23] Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors
    Abduo, Jaafar
    Elseyoufi, Mohamed
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2018, 26 (03): : 101 - 121
  • [24] Three-Dimensional Scanning Accuracy of Intraoral Scanners for Dental Implant Scan Bodies-An Original Study
    Rotaru, Cristian
    Bica, Elena Adina
    Butnarasu, Cristian
    Sandulescu, Mihai
    [J]. MEDICINA-LITHUANIA, 2023, 59 (11):
  • [25] Effect of preparation type on the accuracy of different intraoral scanners: An in vitro study at different levels of accuracy evaluation
    Abduo, Jaafar
    Laskey, David
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (08) : 1221 - 1229
  • [26] Effect of different span lengths with different total occlusal convergences on the accuracy of intraoral scanners
    Yehia, Ashraf
    Abo El Fadl, Ahmad
    El Sergany, Omar
    Ebeid, Kamal
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (03): : 252 - 258
  • [27] Effect of Different Intraoral Scanners on the Accuracy of Bite Registration in Edentulous Maxillary and Mandibular Arches
    Rutkunas, Vygandas
    Jegelevicius, Darius
    Gedrimiene, Agne
    Auskalnis, Liudas
    Eyuboglu, Tan Firat
    Ozcan, Mutlu
    Husain, Nadin Al-Haj
    Akulauskas, Mykolas
    Pletkus, Justinas
    [J]. JOURNAL OF DENTISTRY, 2024, 146
  • [28] Digital impressions in dentistry—accuracy of impression digitalisation by desktop scanners
    Cornelius Runkel
    Jan-Frederik Güth
    Kurt Erdelt
    Christine Keul
    [J]. Clinical Oral Investigations, 2020, 24 : 1249 - 1257
  • [29] Measured accuracy of intraoral scanners is highly dependent on methodical factors
    Peroz, Simon
    Spies, Benedikt Christopher
    Adali, Ufuk
    Beuer, Florian
    Wesemann, Christian
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 318 - 325
  • [30] Accuracy of full-arch scans using intraoral scanners
    Patzelt, Sebastian B. M.
    Emmanouilidi, Archontia
    Stampf, Susanne
    Strub, Joerg R.
    Att, Wael
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1687 - 1694