Quantifying the 4D PET/CT Volumetric Distortions: A 4D Dynamic Phantom Study Based On Pre-Recorded Patient Data

被引:0
|
作者
Ionascu, D.
Park, S.
Mamede-Lewer, M.
Gerbaudo, V.
Killoran, J.
Berbeco, R.
机构
关键词
D O I
10.1118/1.3181263
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-FF-I142
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study
    Bernatowicz, K.
    Keall, P.
    Mishra, P.
    Knopf, A.
    Lomax, A.
    Kipritidis, J.
    MEDICAL PHYSICS, 2015, 42 (01) : 324 - 334
  • [32] Model-Based Deconvolution for 4D PET
    Li, T.
    Li, X.
    Yang, Y.
    Li, F.
    Heron, D.
    Huq, M.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [33] A 4D digital phantom for patient-specific simulation of brain CT perfusion protocols
    van den Boom, Rieneke
    Manniesing, Rashindra
    Oei, Marcel T. H.
    van der Woude, Willem-Jan
    Smit, Ewoud J.
    Laue, Hendrik O. A.
    van Ginneken, Bram
    Prokop, Mathias
    MEDICAL PHYSICS, 2014, 41 (07)
  • [34] A feasibility study on evaluation of moving phantom for 4D radiotherapy
    Lim, S
    Yi, B
    Ahn, S
    Kim, J
    Lee, S
    Shin, S
    Choi, E
    MEDICAL PHYSICS, 2005, 32 (06) : 1921 - 1922
  • [35] 4D CBCT reconstruction with TV regularization on a dynamic software phantom
    Heylen, Rob
    Schramm, Georg
    Suetens, Paul
    Nuyts, Johan
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [36] Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans
    Killoran, Joseph H.
    Gerbaudo, Victor H.
    Mamede, Marcelo
    Ionascu, Dan
    Park, Sang-June
    Berbeco, Ross
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 261 - 274
  • [37] Influence of 4D CT Motion Artifacts on Correspondence Model-based 4D Dose Accumulation
    Sothmann, Thilo
    Gauer, Tobias
    Werner, Rene
    MEDICAL IMAGING 2018: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2018, 10576
  • [38] CT-PET image fusion using the 4D NCAT phantom with the purpose of attenuation correction
    Segars, WP
    Tsui, BMW
    Da Silva, AJ
    Shao, L
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1775 - 1779
  • [39] A Spatiotemporal Volumetric Interpolation Network for 4D Dynamic Medical Image
    Guo, Yuyu
    Bi, Lei
    Ahn, Euijoon
    Feng, Dagan
    Wang, Qian
    Kim, Jinman
    2020 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2020, : 4725 - 4734
  • [40] Validation of a 4D PET tumor segmentation algorithm with experimental phantom measurements
    Carles, M.
    Fechter, T.
    Christ, U.
    Nanko, N.
    Schaefer, A.
    Mix, M.
    Nestle, U.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S391 - S391