Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease

被引:164
|
作者
Johnson, Thorsten R. C.
Nikolaou, Konstantin
Busch, Stephanie
Leber, Alexander W.
Becker, Alexander
Wintersperger, Bernd J.
Rist, Carsten
Knez, Andreas
Reiser, Maximilian F.
Becker, Christoph R.
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Med Clin 1, Munich, Germany
关键词
dual source CT; CT coronary angiography; coronary artery disease; sensitivity; specificity;
D O I
10.1097/RLI.0b013e31806907d0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to evaluate the diagnostic accuracy of dual-source computed tomography (DSCT) with reference to invasive coronary angiography in the diagnosis of coronary artery disease (CAD) on a per-patient as well as on a per-segment basis. Materials and Methods: Thirty-five patients with known or suspected CAD underwent both DSCT (Somatom Definition, Siemens Medical Solutions) and quantitative x-ray coronary angiography (QCA). Parameters of CT acquisition were gantry rotation time 0.330 seconds (ie, temporal resolution 83 milliseconds), tube vol 120 kV, tube current 560 mA with ECG-triggered tube current modulation and full current at 70% of the cardiac cycle for heart rates below 70 beats per minute or full current between 30% and 80% for higher and arrhythmic heart rates. The pitch was also adapted to the heart rate, ranging from 0.2 to 0.43. Volume and flow rate of contrast material (Ultravist 370, Schering AG) were adapted to the patient's body weight. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of DSCT in the detection or exclusion of significant CAD (ie, stenoses > 50%) were evaluated on a per-patient and per-segment basis. Results: All 35 CT angiograms were of diagnostic image quality. QCA demonstrated significant CAD in 48% (n = 17) and nonsignificant disease or normal coronary angiograms in 52% (n = 18) of the patients. Sensitivity, specificity, PPV, and NPV of DSCT on a per-patient basis were 100%, 89%, 89%, and 100%, respectively. On a per-segment basis, 473 of 481 coronary artery segments were assessable (98%). QCA demonstrated stenoses > 50% in 32 segments (7%), and no disease or nonsignificant disease in 433 segments (93%). For the detection of stenoses > 50% on a per-segment basis, DSCT showed a sensitivity, specificity, PPV, and NPV of 88%, 98%, 78%, and 99%, respectively. Conclusions: The comparison of coronary DSCT with QCA shows a very robust image quality and a high diagnostic accuracy in a patient-based as well as a per-segment analysis. Maximal sensitivity and NPV in the per-patient analysis show the strength of the technique in ruling out significant CAD.
引用
收藏
页码:684 / 691
页数:8
相关论文
共 50 条
  • [21] Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy
    Alkadhi, Hatem
    Scheffel, Hans
    Desbiolles, Lotus
    Gaemperli, Oliver
    Stolzmann, Paul
    Plass, Andre
    Goerres, Gerhard W.
    Luescher, Thomas F.
    Genoni, Michele
    Marincek, Borut
    Kaufmann, Philipp A.
    Leschka, Sebastian
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (06) : 766 - 776
  • [22] Unilateral Pulmonary Artery Agenesis Noninvasive Diagnosis With Dual-Source Computed Tomography
    Johnson, T. R. C.
    Thieme, S. F.
    Deutsch, M. -A.
    Hinterseer, M.
    Reiser, M. F.
    Becker, C. R.
    Nikolaou, K.
    [J]. CIRCULATION, 2009, 119 (08) : 1158 - 1160
  • [23] Diagnostic Accuracy and Image Quality of Cardiac Dual-Source Computed Tomography in Patients with Arrhythmia
    Drosch, Tanja
    Reimann, Anja
    Brodoefel, Harald
    Tsiflikas, Ilias
    Thomas, Christoph
    Heuschmid, Martin
    Schroeder, Stephen
    Burgstahler, Christof
    [J]. CIRCULATION, 2008, 118 (18) : S845 - S845
  • [24] Diagnostic accuracy and image quality of cardiac dual-source computed tomography in patients with arrhythmia
    Burgstahler, C.
    Drosch, T.
    Brodoefel, H.
    Reimann, A.
    Tsiflikas, I.
    Thomas, C.
    Heuschmid, M.
    Kopp, A.
    Schroeder, S.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 248 - 248
  • [25] Diagnostic accuracy and image quality of cardiac dual-source computed tomography in patients with arrhythmia
    Tsiflikas, Ilias
    Drosch, Tanja
    Brodoefel, Harald
    Thomas, Christoph
    Reimann, Anja
    Till, Alexander
    Nittka, Daniel
    Kopp, Andreas F.
    Schroeder, Stephen
    Heuschmid, Martin
    Burgstahler, Christof
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 143 (01) : 79 - 85
  • [26] Diagnostic accuracy of dual-source coronary computed tomography angiography in patients after bypass grafting: comparison with invasive coronary angiography
    Kepka, C.
    Opolski, M. P.
    Pregowski, J.
    Kruk, M.
    Kowalewska, A.
    Wilkonska, P.
    Witkowski, A.
    Ruzyllo, W.
    Demkow, M.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 411 - 411
  • [27] Congenital anomalies of coronary arteries in complex congenital heart disease: diagnosis with dual-source computed tomography
    Yu, Fangfang
    Lu, Bin
    Gao, Yang
    Hou, Zhihui
    Cao, Huili
    [J]. CARDIOLOGY, 2013, 126 : 89 - 89
  • [28] Cardiac dual-source computed tomography in unselected patients with severe coronary calcifications and a high prevalence of coronary artery disease
    Burgstahler, C.
    Reimann, A.
    Heuschmid, M.
    Tsiflikas, I.
    Brodoefel, H.
    Kopp, A. F.
    Schroeder, S.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 22 - 22
  • [29] Combining dual-source computed tomography coronary angiography and calcium scoring: added value for the assessment of coronary artery disease
    Leschka, S.
    Scheffel, H.
    Desbiolles, L.
    Plass, A.
    Gaemperli, O.
    Stolzmann, P.
    Genoni, M.
    Luescher, T.
    Marincek, B.
    Kaufmann, P.
    Alkadhi, H.
    [J]. HEART, 2008, 94 (09) : 1154 - 1161
  • [30] Bilateral coronary artery to main pulmonary artery fistula visualized by dual-source computed tomography coronary angiography
    Cui, Xing-Yu
    Cai, Song
    Cui, Zhi-Min
    Chen, Hong-Wei
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (03) : 709 - 710