Diagnostic accuracy and image quality of cardiac dual-source computed tomography in patients with arrhythmia

被引:22
|
作者
Tsiflikas, Ilias [2 ]
Drosch, Tanja [3 ]
Brodoefel, Harald [2 ]
Thomas, Christoph [2 ]
Reimann, Anja [2 ]
Till, Alexander [3 ]
Nittka, Daniel [3 ]
Kopp, Andreas F. [2 ]
Schroeder, Stephen [4 ]
Heuschmid, Martin [2 ]
Burgstahler, Christof [1 ]
机构
[1] Univ Tubingen, Dept Internal Med Sports Med, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Diagnost Radiol, Tubingen, Germany
[3] Univ Tubingen Hosp, Dept Cardiol, Tubingen, Germany
[4] Klinikum Eichert, Goeppingen, Germany
关键词
CORONARY-ARTERY-DISEASE; HEART-RATE; INITIAL-EXPERIENCE; ATRIAL-FIBRILLATION; ANGIOGRAPHY; CT; VISUALIZATION;
D O I
10.1016/j.ijcard.2009.01.074
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiac multi-detector computed tomography (MDCT) permits accurate visualization of high-grade coronary artery stenosis. However, in patients with heart rate irregularities, MDCT was found to have limitations. Thus, the aim of the present study was to evaluate the diagnostic accuracy of a new dual-source computed tomography (DSCT) scanner generation with 83 ms temporal resolution in patients without stable sinus rhythm. Methods: 44 patients (31 men, mean age 67.5 +/- 9.2 years) without stable sinus rhythm and scheduled for invasive coronary angiography (ICA) because of suspected (n = 17) or known coronary artery disease (CAD, n = 27) were included in this study. All patients were examined with DSCT (Somatom Definition T, Siemens). Besides assessment of total calcium score, all coronary segments were analyzed with regard to the presence of significant coronary artery lesions (>50%). The findings were compared to ICA in a blinded fashion. Results: During CT examination, heart rhythm was as follows: 25 patients (57%) atrial fibrillation, 7 patients (16%) ventricular extrasystoles (two of them with atrial fibrillation), 4 patients (9%) supraventricular extrasystoles, 10 patients (23%) sinus arrhythmia (heart rate variability >10 bpm). Mean heart rate was 69 +/- 14 bpm, median 65 bpm. Mean Agatston score equivalent (ASE) was 762, ranging from 0 to 4949.7 ASE. Prevalence of CAD was 68% (30/44). 155 segments (27%) showed "step-ladder" artifacts and 28 segments (5%) could not be visualized by DSCT. Only 70 segments (12%) were completely imaged without any artifacts. Based on a coronary segment model, sensitivity was 73%, specificity 91%, positive predictive value 63%, and negative predictive value 94% for the detection of significant lesions (>= 50% diameter stenosis). Overall accuracy was 88%. Conclusions: In patients with heart rate irregularities, including patients with atrial fibrillation and a high prevalence of coronary artery disease, the diagnostic yield of dual-source computed tomography is still hampered due to a high number of segments with "step-ladder" artifacts. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [1] Diagnostic Accuracy and Image Quality of Cardiac Dual-Source Computed Tomography in Patients with Arrhythmia
    Drosch, Tanja
    Reimann, Anja
    Brodoefel, Harald
    Tsiflikas, Ilias
    Thomas, Christoph
    Heuschmid, Martin
    Schroeder, Stephen
    Burgstahler, Christof
    [J]. CIRCULATION, 2008, 118 (18) : S845 - S845
  • [2] Diagnostic accuracy and image quality of cardiac dual-source computed tomography in patients with arrhythmia
    Burgstahler, C.
    Drosch, T.
    Brodoefel, H.
    Reimann, A.
    Tsiflikas, I.
    Thomas, C.
    Heuschmid, M.
    Kopp, A.
    Schroeder, S.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 248 - 248
  • [3] Cardiac dual-source computed tomography - Effect of body mass index on image quality and diagnostic accuracy
    Brodoefel, Harald
    Tsiflikas, Ilias
    Burgstahler, Christof
    Reimann, Anja
    Thomas, Christoph
    Schroeder, Stephen
    Kopp, Andreas F.
    Claussen, Claus D.
    Heuschmid, Martin
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (10) : 712 - 718
  • [4] Dual-source cardiac computed tomography: image quality and dose considerations
    Achenbach, Stephan
    Anders, Katharina
    Kalender, Willi A.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (06) : 1188 - 1198
  • [5] Dual-source cardiac computed tomography: image quality and dose considerations
    Stephan Achenbach
    Katharina Anders
    Willi A. Kalender
    [J]. European Radiology, 2008, 18 : 1188 - 1198
  • [6] Radiation Dose and Image Quality of Prospective Triggering With Dual-Source Cardiac Computed Tomography
    Blankstein, Ron
    Shah, Amar
    Pale, Rodrigo
    Abbara, Suhny
    Bezerra, Hiram
    Bolen, Michael
    Mamuya, Wilfred S.
    Hoffmann, Udo
    Brady, Thomas J.
    Cury, Ricardo C.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (08): : 1168 - 1173
  • [7] Diagnostic accuracy of low-dose dual-source cardiac computed tomography as compared to surgery in univentricular heart patients
    Chaosuwannakit, Narumol
    Makarawate, Pattarapong
    [J]. JOURNAL OF CARDIOTHORACIC SURGERY, 2018, 13
  • [8] Diagnostic accuracy of low-dose dual-source cardiac computed tomography as compared to surgery in univentricular heart patients
    Narumol Chaosuwannakit
    Pattarapong Makarawate
    [J]. Journal of Cardiothoracic Surgery, 13
  • [9] Diagnostic accuracy of dual-source coronary computed tomography angiography in patients after bypass grafting
    Kepka, Cezary
    Opolski, Maksymilian
    Kruk, Mariusz
    Pregowski, Jerzy
    Kowalewska, Anna
    Wilkowska, Paulina
    Dzielinska, Zofia
    Karcz, Maciej
    Ruzyllo, Witold
    Demkow, Marcin
    [J]. POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2012, 8 (03): : 183 - 192
  • [10] Dual-source computed tomography in patients with acute chest pain: feasibility and image quality
    Thomas Schertler
    Hans Scheffel
    Thomas Frauenfelder
    Lotus Desbiolles
    Sebastian Leschka
    Paul Stolzmann
    Burkhardt Seifert
    Thomas G. Flohr
    Borut Marincek
    Hatem Alkadhi
    [J]. European Radiology, 2007, 17 : 3179 - 3188