Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease

被引:164
|
作者
Johnson, Thorsten R. C.
Nikolaou, Konstantin
Busch, Stephanie
Leber, Alexander W.
Becker, Alexander
Wintersperger, Bernd J.
Rist, Carsten
Knez, Andreas
Reiser, Maximilian F.
Becker, Christoph R.
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Med Clin 1, Munich, Germany
关键词
dual source CT; CT coronary angiography; coronary artery disease; sensitivity; specificity;
D O I
10.1097/RLI.0b013e31806907d0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to evaluate the diagnostic accuracy of dual-source computed tomography (DSCT) with reference to invasive coronary angiography in the diagnosis of coronary artery disease (CAD) on a per-patient as well as on a per-segment basis. Materials and Methods: Thirty-five patients with known or suspected CAD underwent both DSCT (Somatom Definition, Siemens Medical Solutions) and quantitative x-ray coronary angiography (QCA). Parameters of CT acquisition were gantry rotation time 0.330 seconds (ie, temporal resolution 83 milliseconds), tube vol 120 kV, tube current 560 mA with ECG-triggered tube current modulation and full current at 70% of the cardiac cycle for heart rates below 70 beats per minute or full current between 30% and 80% for higher and arrhythmic heart rates. The pitch was also adapted to the heart rate, ranging from 0.2 to 0.43. Volume and flow rate of contrast material (Ultravist 370, Schering AG) were adapted to the patient's body weight. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of DSCT in the detection or exclusion of significant CAD (ie, stenoses > 50%) were evaluated on a per-patient and per-segment basis. Results: All 35 CT angiograms were of diagnostic image quality. QCA demonstrated significant CAD in 48% (n = 17) and nonsignificant disease or normal coronary angiograms in 52% (n = 18) of the patients. Sensitivity, specificity, PPV, and NPV of DSCT on a per-patient basis were 100%, 89%, 89%, and 100%, respectively. On a per-segment basis, 473 of 481 coronary artery segments were assessable (98%). QCA demonstrated stenoses > 50% in 32 segments (7%), and no disease or nonsignificant disease in 433 segments (93%). For the detection of stenoses > 50% on a per-segment basis, DSCT showed a sensitivity, specificity, PPV, and NPV of 88%, 98%, 78%, and 99%, respectively. Conclusions: The comparison of coronary DSCT with QCA shows a very robust image quality and a high diagnostic accuracy in a patient-based as well as a per-segment analysis. Maximal sensitivity and NPV in the per-patient analysis show the strength of the technique in ruling out significant CAD.
引用
收藏
页码:684 / 691
页数:8
相关论文
共 50 条
  • [1] Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography
    Ropers, Ulrike
    Ropers, Dieter
    Pflederer, Tobias
    Anders, Katharina
    Kuettner, Axel
    Stilianakis, Nikolaos I.
    Komatsu, Sei
    Kalender, Willi
    Bautz, Werner
    Daniel, Werner G.
    Achenbach, Stephan
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (25) : 2393 - 2398
  • [2] Dual-source computed tomography coronary artery imaging in children
    Secinaro, Aurelio
    Curione, Davide
    Mortensen, Kristian Havmand
    Santangelo, Teresa Pia
    Ciancarella, Paolo
    Napolitano, Carmela
    Del Pasqua, Alessia
    Taylor, Andrew Mayall
    Ciliberti, Paolo
    [J]. PEDIATRIC RADIOLOGY, 2019, 49 (13) : 1823 - 1839
  • [3] Dual-source computed tomography coronary artery imaging in children
    Aurelio Secinaro
    Davide Curione
    Kristian Havmand Mortensen
    Teresa Pia Santangelo
    Paolo Ciancarella
    Carmela Napolitano
    Alessia Del Pasqua
    Andrew Mayall Taylor
    Paolo Ciliberti
    [J]. Pediatric Radiology, 2019, 49 : 1823 - 1839
  • [4] Diagnostic Accuracy of Dual-Source 64-Slice Multidetector Computed Tomography in Evaluation of Coronary Artery Bypass Grafts
    Sahiner, Levent
    Canpolat, Ugur
    Yorgun, Hikmet
    Hazirolan, Tuncay
    Karcaaltincaba, Musturay
    Sunman, Hamza
    Kaya, Ergun Baris
    Aytemir, Kudret
    Oto, Ali
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2012, 60 (08) : 1180 - 1185
  • [5] Diagnostic accuracy of dual-source coronary computed tomography angiography in patients after bypass grafting
    Kepka, Cezary
    Opolski, Maksymilian
    Kruk, Mariusz
    Pregowski, Jerzy
    Kowalewska, Anna
    Wilkowska, Paulina
    Dzielinska, Zofia
    Karcz, Maciej
    Ruzyllo, Witold
    Demkow, Marcin
    [J]. POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2012, 8 (03): : 183 - 192
  • [6] Accuracy of dual-source computed tomography to identify significant coronary artery disease in patients with atrial fibrillation: comparison with coronary angiography
    Marwan, Mohamed
    Pflederer, Tobias
    Schepis, Tiziano
    Lang, Alexandra
    Muschiol, Gerd
    Ropers, Dieter
    Daniel, Werner G.
    Achenbach, Stephan
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (18) : 2230 - 2237
  • [7] Diagnostic accuracy of first generation dual-source computed tomography in the assessment of coronary artery disease: a meta-analysis from 24 studies
    Guo, Shun-Lin
    Guo, You-Min
    Zhai, Ya-Nan
    Ma, Bin
    Wang, Ping
    Yang, Ke-hu
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (06): : 755 - 771
  • [8] Diagnostic accuracy of first generation dual-source computed tomography in the assessment of coronary artery disease: a meta-analysis from 24 studies
    Shun-Lin Guo
    You-Min Guo
    Ya-Nan Zhai
    Bin Ma
    Ping Wang
    Ke-hu Yang
    [J]. The International Journal of Cardiovascular Imaging, 2011, 27 : 755 - 771
  • [9] Coronary artery anomalies, detection by dual-source computed tomography angiography
    Vliegen, H. W.
    [J]. NETHERLANDS HEART JOURNAL, 2010, 18 (10): : 464 - 465
  • [10] Coronary artery anomalies, detection by dual-source computed tomography angiography
    H. W. Vliegen
    [J]. Netherlands Heart Journal, 2010, 18 : 464 - 465