Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography

被引:197
|
作者
Ropers, Ulrike [1 ]
Ropers, Dieter [1 ]
Pflederer, Tobias [1 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Stilianakis, Nikolaos I. [4 ,5 ]
Komatsu, Sei [1 ]
Kalender, Willi [3 ]
Bautz, Werner [2 ]
Daniel, Werner G. [1 ]
Achenbach, Stephan [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med Cardiol Angiol 2, Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Diagnost Radiol, Erlangen, Germany
[3] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[4] Univ Erlangen Nurnberg, Dept Biometry & Epidemiol, Erlangen, Germany
[5] Commiss European Communities, Joint Res Ctr, I-21020 Ispra, VA, Italy
关键词
D O I
10.1016/j.jacc.2007.09.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We evaluated the influence of heart rate on image quality and diagnostic accuracy of dual-source computed tomography (DSCT) coronary angiography. Background Multidetector computed tomography (MDCT) coronary angiography has demonstrated an inverse relationship between heart rate and image quality. Dual-source CT provides a higher temporal resolution. Methods One hundred patients were studied by DSCT (DEFINITION, Siemens Medical Solutions, Forchheim, Germany). A contrast-enhanced volume dataset was acquired (two tubes, 120 kV, 400 mAs/rot, collimation 64 x 0.6 mm). Datasets were evaluated concerning the presence of significant coronary stenoses and validated against invasive coronary angiography. Results In 44 patients with a heart rate >= 65 beats/min, 566 of 616 coronary segments were evaluable (92%), whereas in 56 patients with a heart rate <65 beats/min, 777 of 778 coronary segments were evaluable (100%, p < 0.001). On a per-patient basis, 93% of patients (>= 65 beats/min) and 100% of patients (<65 beats/min) were considered evaluable. By classifying unevaluable segments as positive for stenosis, per-patient sensitivity was 95% (19 of 20) for heart rates >= 65 beats/min and 100% (22 of 22) for heart rates <65 beats/min. Specificity was 87% (21 of 24) versus 76% (26 of 34), and overall diagnostic accuracy was 91% (40 of 44) versus 86% (48 of 56). None of these differences were statistically significant. Similarly, no difference in diagnostic accuracy was found in per-vessel and -segment analyses. Conclusions In 100 patients studied without beta-blocker pre-medication, DSCT demonstrated slightly lower per-segment evaluability for high heart rates but no decrease in diagnostic accuracy for the detection of coronary artery stenoses.
引用
收藏
页码:2393 / 2398
页数:6
相关论文
共 50 条
  • [1] Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy
    Alkadhi, Hatem
    Scheffel, Hans
    Desbiolles, Lotus
    Gaemperli, Oliver
    Stolzmann, Paul
    Plass, Andre
    Goerres, Gerhard W.
    Luescher, Thomas F.
    Genoni, Michele
    Marincek, Borut
    Kaufmann, Philipp A.
    Leschka, Sebastian
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (06) : 766 - 776
  • [2] Dual-source computed tomography coronary angiography in patients with high heart rate
    Fujimura, Tatsuhiro
    Miura, Toshiro
    Nao, Tomoko
    Yoshimura, Masayuki
    Nakashima, Yoshiteru
    Okada, Munemasa
    Okamura, Takayuki
    Yamada, Jutaro
    Ohshita, Chikage
    Wada, Yasuaki
    Matsunaga, Naofumi
    Matsuzaki, Masunori
    Yano, Masafumi
    [J]. HEART AND VESSELS, 2014, 29 (04) : 443 - 448
  • [3] Dual-source computed tomography coronary angiography in patients with high heart rate
    Tatsuhiro Fujimura
    Toshiro Miura
    Tomoko Nao
    Masayuki Yoshimura
    Yoshiteru Nakashima
    Munemasa Okada
    Takayuki Okamura
    Jutaro Yamada
    Chikage Ohshita
    Yasuaki Wada
    Naofumi Matsunaga
    Masunori Matsuzaki
    Masafumi Yano
    [J]. Heart and Vessels, 2014, 29 : 443 - 448
  • [4] Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography
    Laspas, Fotios
    Tsantioti, Dimitra
    Roussakis, Arkadios
    Kritikos, Nikolaos
    Efthimiadou, Roxani
    Kehagias, Dimitrios
    Andreou, John
    [J]. ACTA RADIOLOGICA, 2011, 52 (03) : 273 - 277
  • [5] Diagnostic accuracy of dual-source coronary computed tomography angiography in patients after bypass grafting
    Kepka, Cezary
    Opolski, Maksymilian
    Kruk, Mariusz
    Pregowski, Jerzy
    Kowalewska, Anna
    Wilkowska, Paulina
    Dzielinska, Zofia
    Karcz, Maciej
    Ruzyllo, Witold
    Demkow, Marcin
    [J]. POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2012, 8 (03): : 183 - 192
  • [6] Safety and accuracy of dual-source coronary computed tomography angiography in the pediatric population
    Han, B. Kelly
    Lindberg, Jana
    Overman, David
    Schwartz, Robert S.
    Grant, Katharine
    Lesser, John R.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (04) : 252 - 259
  • [7] Diagnostic accuracy of dual-source coronary computed tomography angiography in patients after bypass grafting: comparison with invasive coronary angiography
    Kepka, C.
    Opolski, M. P.
    Pregowski, J.
    Kruk, M.
    Kowalewska, A.
    Wilkonska, P.
    Witkowski, A.
    Ruzyllo, W.
    Demkow, M.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 411 - 411
  • [8] Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease
    Johnson, Thorsten R. C.
    Nikolaou, Konstantin
    Busch, Stephanie
    Leber, Alexander W.
    Becker, Alexander
    Wintersperger, Bernd J.
    Rist, Carsten
    Knez, Andreas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (10) : 684 - 691
  • [9] Diagnostic accuracy of dual-source computed tomography in the detection of coronary chronic total occlusion: Comparison with invasive angiography
    Li, Jiayi
    Li, Xue
    Wei, Mengqi
    Zhao, Hongliang
    Zheng, Minwen
    [J]. AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (19): : 3854 - 3858
  • [10] Diagnostic accuracy of dual source computed tomography coronary angiography in patients referred for conventional angiography
    Weustink, Annick C.
    Mollet, Nico R.
    Meijboom, Willem B.
    Krestin, Gabriel P.
    de Feyter, Pim J.
    [J]. CIRCULATION, 2006, 114 (18) : 448 - 448