Optimization of treatment isocenter location in single-isocenter LINAC-based stereotactic radiosurgery for management of multiple brain metastases

被引:10
|
作者
Cui, Taoran [1 ]
Zhou, Yongkang [2 ]
Yue, Ning J. [1 ]
Vergalasova, Irina [1 ]
Zhang, Yin [1 ]
Zhu, Jiahua [1 ]
Nie, Ke [1 ]
机构
[1] Rutgers Canc Inst New Jersey, Dept Radiat Oncol, New Brunswick, NJ 08901 USA
[2] Zhongshan Hosp, Dept Radiat Oncol, Shanghai, Peoples R China
关键词
UNCERTAINTIES; RADIOTHERAPY; NUMBER;
D O I
10.1002/mp.15294
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Single-isocenter linear accelerator (LINAC)-based stereotactic radiosurgery (SRS) has become a promising treatment technique for the management of multiple brain metastases. Because of the high prescription dose and steep dose gradient, SRS plans are sensitive to geometric errors, resulting in loss of target coverage and suboptimal local tumor control. Current planning techniques rely on adding a uniform and isotropic setup margin to all gross tumor volumes (GTVs) to account for rotational uncertainties. However, this setup margin may be insufficient, since the magnitude of rotational uncertainties varies and is dependent upon the distance between a GTV and the isocenter. In this study, we designed a framework to determine the optimal isocenter of a single-isocenter SRS plan for multiple brain metastases using stochastic optimization to mitigate potential errors resulting from rotational uncertainties. Methods Planning target volumes (PTVs), defined as GTVs plus a 1-mm margin following common SRS planning convention, were assumed to be originally treated with a prescription dose and therefore covered by the prescription isodose cloud. The dose distribution, including the prescription isodose, was considered invariant assuming small rotations throughout the study. A stochastic optimization scheme was developed to determine the location of the optimal isocenter, so that the prescription dose coverage of rotated GTVs, equivalent to the intersecting volumes between the rotated GTVs and original PTVs, was maximized for any random small rotations about the isocenter. To evaluate the coverage of GTVs, the expected V100% undergoing random rotations was approximated as the sample average V100% undergoing a predetermined number of rotations. The expected V100% of each individual GTV and total GTVs was then compared between the plans using the optimal isocenter and the center-of-mass (CoM), respectively. Results Twenty-two patients previously treated for multiple brain metastases in a single institute were included in this retrospective study. Each patient was initially treated for more than three brain metastases (mean: 7.6; range: 3-15) with the average GTV volume of 0.89 cc (range: 0.03-11.78 cc). The optimal isocenter found for each patient was significantly different from the CoM, with the average Euclidean distance between the optimal isocenter and the CoM being 4.36 +/- 2.59 cm. The dose coverage to GTVs was also significantly improved (paired t-test; p < 0.001) when the optimal isocenter was used, with the average V100% of total GTVs increasing from 87.1% (standard deviation as std: 11.7%; range: 39.9-98.2%) to 94.2% (std: 5.4%; range: 77.7-99.4%). The volume of a GTV was positively correlated with the expected V100% regardless of the isocenter used (Spearman coefficient: rho=0.66; p < 0.001). The distance between a GTV and the isocenter was negatively correlated with the expected V100% when the CoM was used (rho=-0.21; p = 0.004), however no significant correlation was found when the optimal isocenter was used (rho=-0.11; p = 0.137). Conclusion The proposed framework provides an effective approach to determine the optimal isocenter of single-isocenter LINAC-based SRS plans for multiple brain metastases. The implementation of the optimal isocenter results in SRS plans with consistently higher target coverage despite potential rotational uncertainties, and therefore significantly improves SRS plan robustness against random rotational uncertainties.
引用
收藏
页码:7632 / 7640
页数:9
相关论文
共 50 条
  • [31] Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA)
    Huang, Yimei
    Chin, Karen
    Robbins, Jared R.
    Kim, Jinkoo
    Li, Haisen
    Amro, Hanan
    Chetty, Indrin J.
    Gordon, James
    Ryu, Samuel
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) : 128 - 132
  • [32] Single-Isocenter, Volumetric Modulated Arc Radiosurgery for Multiple Brain Metastases in a Single Session
    Knuthson, A. R.
    Widdel, L.
    Dial, C.
    Petit, J. H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E267 - E267
  • [33] Characterizing Isocenter Reproducibility for Linac-Based Stereotactic Treatment Accuracy
    Pinkham, D.
    Hancock, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E598 - E598
  • [34] Comparison of dosimetric impact of intra-fractional setup discrepancy between multiple- and single-isocenter approaches in linac-based stereotactic radiotherapy of multiple brain metastases
    Tsui, Sylvia S. W.
    Wu, Vincent W. C.
    Cheung, Jerry S. C.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02):
  • [35] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Giorgio Hamid Raza
    Luca Capone
    Paolo Tini
    Martina Giraffa
    Piercarlo Gentile
    Giuseppe Minniti
    [J]. Radiation Oncology, 17
  • [36] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Raza, Giorgio Hamid
    Capone, Luca
    Tini, Paolo
    Giraffa, Martina
    Gentile, Piercarlo
    Minniti, Giuseppe
    [J]. RADIATION ONCOLOGY, 2022, 17 (01)
  • [37] Dosimetric Comparison between Single-Isocenter RapidArc and Multi-Isocenter Circular Cone Arc for Radiosurgery to Multiple Brain Metastases
    Dai, P.
    Zhang, P.
    Luo, L.
    Deng, G.
    Huang, Q.
    Cai, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E508 - E508
  • [38] Radiosurgery of Multiple Brain Metastases with Single-Isocenter VMAT: Optimizing Treatment Geometry to Reduce Normal Brain Dose
    Wu, Q.
    Snyder, K.
    Liu, C.
    Huang, Y.
    Li, H.
    Chetty, I.
    Wen, N.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3576 - 3576
  • [39] Impact of setup errors on the robustness of linac-based single-isocenter coplanar and non-coplanar VMAT plans for multiple brain metastases
    Sun, Xiaohuan
    Guan, Fada
    Yun, Qinghui
    Jennings, Matthew
    Biggs, Simon
    Wang, Zhongfei
    Wang, Wei
    Zhang, Te
    Shi, Mei
    Zhao, Lina
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (07):
  • [40] Single isocenter treatment planning techniques for stereotactic radiosurgery of multiple cranial metastases
    Velten, Christian
    Kabarriti, Rafi
    Garg, Madhur
    Tome, Wolfgang A.
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 17 : 47 - 52