Year long monitoring of indoor air quality and ventilation in school classrooms in Victoria, Australia

被引:12
|
作者
Rajagopalan, Priyadarsini [1 ]
Andamon, Mary Myla [1 ]
Woo, Jin [1 ]
机构
[1] RMIT Univ, Sch Property Construct & Project Management, Sustainable Bldg Innovat Lab, 124 La Trobe St, Melbourne, Vic 3000, Australia
关键词
Indoor air quality; school classrooms; CO2; concentration; ventilation; air change rates; particulate matter; RATES; HEALTH; PERFORMANCE; ENVIRONMENT; POLLUTION; RHINITIS; ASTHMA;
D O I
10.1080/00038628.2021.1988892
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Children under 15 years spend over six hours per day in school buildings and are particularly vulnerable to the effects of poor indoor air quality (IAQ). However long-term monitoring of indoor environmental conditions is limited in Australian schools. This study evaluates IAQ in ten Australian school classrooms in the temperate settings of Victoria. Temperature, relative humidity, CO2 concentration, PM2.5 and PM10 were monitored over a period of one year. The temperature and relative humidity values in the monitored classrooms ranged between 18.7 degrees C and 23.8 degrees C and 44-63 RH%, respectively, indicating that the conditions have been mechanically controlled. The average air change (ACH) rates in the 10 school classrooms varied considerably (range: 0.7-4.83 ACH). The ventilation rates ranged from 1.6 Ls(-1) to 11.5 Ls(-1) per person with 7 out of the 10 classrooms showing ventilation rates below the recommended minimum. This study points to the need for increasing ventilation rates in classrooms.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [21] Ventilation and Indoor Air Quality
    Kumar, Ashok
    Moreno-Rangel, Alejandro
    Khan, M. Amirul, I
    Piasecki, Michal
    ATMOSPHERE, 2022, 13 (10)
  • [22] Improving Indoor Air Quality in Classrooms via Wind-Induced Natural Ventilation
    Bayoumi, Mohannad
    MODELLING AND SIMULATION IN ENGINEERING, 2021, 2021
  • [23] Indoor Air Quality Assessment: Comparison of Ventilation Scenarios for Retrofitting Classrooms in a Hot Climate
    Calama-Gonzalez, Carmen Maria
    Leon-Rodriguez, Angel Luis
    Suarez, Rafael
    ENERGIES, 2019, 12 (24)
  • [24] PERCEIVED INDOOR AIR QUALITY RELATED TO VENTILATION RATES AND SCHOOL PERFORMANCE
    Badida, Miroslav
    Senitkov, Ingrid
    GEOCONFERENCE ON ENERGY AND CLEAN TECHNOLOGIES, 2013, : 733 - 740
  • [25] Indoor air quality and occupants' ventilation habits in China: Seasonal measurement and long-term monitoring
    Liu, Junjie
    Dai, Xilei
    Li, Xiangdong
    Jia, Susu
    Pei, Jingjing
    Sun, Yuexia
    Lai, Dayi
    Shen, Xiong
    Sun, Hejiang
    Yin, Haiguo
    Huang, Kailiang
    Tan, Hongwei
    Gao, Yao
    Jian, Yiwen
    BUILDING AND ENVIRONMENT, 2018, 142 : 119 - 129
  • [26] Assessment of indoor air quality in university classrooms
    Kraus, Michal
    Novakova, Petra
    10TH INTERNATIONAL SCIENTIFIC CONFERENCE BUILDING DEFECTS (BUILDING DEFECTS 2018), 2019, 279
  • [27] Indoor air quality investigations at five classrooms
    Lee, SC
    Chang, M
    INDOOR AIR, 1999, 9 (02) : 134 - 138
  • [28] Effect of natural ventilation and manual airing on indoor air quality in naturally ventilated Italian classrooms
    Stabile, Luca
    Dell'Isola, Marco
    Frattolillo, Andrea
    Massimo, Angelamaria
    Russi, Aldo
    BUILDING AND ENVIRONMENT, 2016, 98 : 180 - 189
  • [29] The effect of ventilation on air particulate matter in school classrooms
    Trompetter, W. J.
    Boulic, M.
    Ancelet, T.
    Garcia-Ramirez, J. C.
    Davy, P. K.
    Wang, Y.
    Phipps, R.
    JOURNAL OF BUILDING ENGINEERING, 2018, 18 : 164 - 171
  • [30] Ventilation for acceptable indoor air quality
    ASHRAE Standard, 2007, (62.1-2007): : 1 - 41