Effect of natural ventilation and manual airing on indoor air quality in naturally ventilated Italian classrooms

被引:91
|
作者
Stabile, Luca [1 ]
Dell'Isola, Marco [1 ]
Frattolillo, Andrea [2 ]
Massimo, Angelamaria [1 ]
Russi, Aldo [1 ]
机构
[1] Univ Cassino & Southern Lazio, Dept Civil & Mech Engn, Via Di Biasio 43, I-03043 Cassino, FR, Italy
[2] Univ Cagliari, Dept Civil & Environm Engn & Architecture, Cagliari, Italy
关键词
Schools; Exposure; Particles; Radon; Airing; Blower-door test; CO2; CARBON-DIOXIDE CONCENTRATION; PARTICLE CONCENTRATIONS; PARTICULATE MATTER; THERMAL CONDITIONS; SCHOOLS; HEALTH; SINGLE; INFILTRATION; PENETRATION; TIGHTNESS;
D O I
10.1016/j.buildenv.2016.01.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present work aimed to evaluate the effect of the ventilation on indoor air quality in Italian classrooms. To this end, schools located in the Central Italy were considered in the survey. The results of two experimental analyses are presented: a) data on classrooms' permeability and resultant air exchange rate, b) trends of indoor air quality parameters during heating and non-heating seasons to assess the possible effect of the manual airing technique. Pressurization tests were performed in 16 classrooms to evaluate their air infiltration due to envelope's leakages. The indoor air quality was investigated in 6 classrooms through CO2, particle number concentration and radon concentration measurements which were also related to the manual airing performed by window opening. Results of the pressurization tests revealed that, even in classrooms characterized by a poor maintenance state, the permeability of the envelopes was too low to guarantee acceptable air exchange rates. The analysis of the classrooms' air quality showed that during the fall and winter seasons the airing was ineffective, while it positively affected the indoor air quality during the spring season when strong reductions in CO2 and radon concentrations were recorded. The effect of the manual airing on the infiltration of outdoor generated pollutants was also assessed. As an example, a greater airing effect resulted in a higher penetration of sub-micrometric particles from outdoor: in fact, particle penetration factors of 0.83 and 1 were measured in fall/winter and spring seasons, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 50 条
  • [1] Indoor Air Quality in Naturally Ventilated Italian Classrooms
    Fuoco, Fernanda Carmen
    Stabile, Luca
    Buonanno, Giorgio
    Trassiera, Concepcion Vargas
    Massimo, Angelamaria
    Russi, Aldo
    Mazaheri, Mandana
    Morawska, Lidia
    Andrade, Alexandro
    ATMOSPHERE, 2015, 6 (11) : 1652 - 1675
  • [2] Indoor Air Quality in UK School Classrooms Ventilated by Natural Ventilation Windcatchers
    Jones, Benjamin M.
    Kirby, Ray
    INTERNATIONAL JOURNAL OF VENTILATION, 2012, 10 (04) : 323 - 337
  • [3] IMPROVING INDOOR AIR QUALITY OF NATURALLY VENTILATED CLASSROOMS IN THE NORTHEAST OF PORTUGAL
    Rodrigues, Filipe
    Feliciano, Manuel
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2019, 18 (07): : 1423 - 1437
  • [4] Air permeability of naturally ventilated Italian classrooms
    Stabile, Luca
    Frattolillo, Andrea
    Dell'Isola, Marco
    Massimo, Angelamaria
    Russi, Aldo
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 3150 - 3155
  • [5] Monitoring and modelling indoor air quality and ventilation in classrooms within a purpose-designed naturally ventilated school
    Kolokotroni, M
    Ge, YT
    Katsoulas, D
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (06) : 316 - 326
  • [6] The effects of manual airing strategies and architectural factors on the indoor air quality in college classrooms: a case study
    Yanzhe Yu
    Bei Wang
    Shijun You
    Tianzhen Ye
    Wandong Zheng
    Shen Wei
    Shuting Yang
    Yuanyuan Wang
    Kun Li
    Air Quality, Atmosphere & Health, 2022, 15 : 1 - 13
  • [7] The effects of manual airing strategies and architectural factors on the indoor air quality in college classrooms: a case study
    Yu, Yanzhe
    Wang, Bei
    You, Shijun
    Ye, Tianzhen
    Zheng, Wandong
    Wei, Shen
    Yang, Shuting
    Wang, Yuanyuan
    Li, Kun
    AIR QUALITY ATMOSPHERE AND HEALTH, 2022, 15 (01): : 1 - 13
  • [8] An integrated evaluation study of the ventilation rate, the exposure and the indoor air quality in naturally ventilated classrooms in the Mediterranean region during spring
    Dorizas, Paraskevi Vivian
    Assimakopoulos, Margarita-Niki
    Helmis, Constantinos
    Santamouris, Mattheos
    SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 502 : 557 - 570
  • [9] The Effect of Ventilation Strategies on Indoor Air Quality and Energy Consumptions in Classrooms
    Stabile, Luca
    Massimo, Angelamaria
    Canale, Laura
    Russi, Aldo
    Andrade, Alexandro
    Dell'Isola, Marco
    BUILDINGS, 2019, 9 (05)
  • [10] Indoor air quality in naturally ventilated dwellings in Spain
    Garcia-Ortega, Sonia
    Linares-Alemparte, Pilar
    INFORMES DE LA CONSTRUCCION, 2023, 75 (572)