The dosimetric advantages of perirectal hydrogel spacer in men with localized prostate cancer undergoing stereotactic ablative radiotherapy (SABR)

被引:2
|
作者
Sturt, Philippa [1 ]
Suh, Yae-Eun [2 ]
Khoo, Vincent [2 ]
机构
[1] Royal Marsden NHS Fdn Trust, Dept Phys, London SW3 6JJ, England
[2] Royal Marsden NHS Fdn Trust, Dept Clin Oncol, London SW3 6JJ, England
关键词
SABR; SBRT; Prostate; Hydrogel spacer; CyberKnife; Radiotherapy;
D O I
10.1016/j.meddos.2022.02.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To evaluate the dosimetric differences for patients receiving a perirectal hydrogel spacer (PR-HS) using SpaceOAR undergoing stereotactic ablative radiotherapy (SABR) for localized prostate cancer with the CyberKnife VSI system. Gold fiducial markers and a PR-HS was inserted in 22 consecutive patients with histologically confirmed localized prostate cancer. For planning comparison, dosimetry from the clinical plans was compared against replans based on a simulated rectum volume designed to recreate a clinically appropriate spacer-less anatomy for each patient. Both sets were planned to 36.25 Gy in 5 fractions using the treatment planning system associated with the CyberKnife VSI system. The aim was to ensure equivalent target coverage for both plans and to evaluate doses to the organs-at-risk (OARs): rectum, bladder and penile bulb. The median PR-HS implant volume was 11.2 cc (range 8.8 to 14.9 cc). The maximal median perirectal separation was 15.5 mm (10.5 to 20.7 mm). Statistically significant reductions were noted for the 3 OARs, with no statistically significant difference in planning target volumes or clinical target volume coverage. All rectal dose constraints were significantly improved in the PR-HS plans with a percentage dose difference of at least 24% (rectum V-18.(1Gy) (%)) to 60.5% (rectum V-36Gy (cc)). The bladder and penile bulb dose constraints parameters were also significantly improved: the bladder V-37Gy was reduced by 17.1%, V-18(.1Gy) was reduced by 4.2%; the penile bulb D-50(%) was reduced by 7.7%. The use of PR-HS was able to significantly reduce planned dose to the rectum, bladder and penile bulb with SABR techniques associated with the CyberKnife VSI system. (C) 2022 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:173 / 176
页数:4
相关论文
共 50 条
  • [41] Predicting acute and late toxicity in prostate cancer stereotactic ablative radiotherapy: the role of dosimetric parameters and prostate volume
    Ozyigit, Gokhan
    Hurmuz, Pervin
    Bayatfard, Pantea
    Tilki, Burak
    Yedekci, Yagiz
    Yilmaz, Melek Tugce
    STRAHLENTHERAPIE UND ONKOLOGIE, 2025,
  • [42] Dosimetric and radiobiological comparison of Cyberknife and Tomotherapy in stereotactic body radiotherapy for localized prostate cancer
    Chen, Chun-You
    Lee, Liang-Ming
    Yu, Hsiao-Wei
    Lee, Steve P.
    Lee, Hsin-Lun
    Lin, Yung-Wei
    Wen, Yu-Ching
    Chen, Yi-Ju
    Chen, Chiu-Ping
    Tsai, Jo-Ting
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (03) : 465 - 477
  • [43] Stereotactic Ablative Radiotherapy (SABR) for Non-Small Cell Lung Cancer
    Iyengar, Puneeth
    Westover, Kenneth
    Timmerman, Robert D.
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 34 (06) : 845 - 854
  • [44] Dosimetric Evaluation and Clinical Implementation of IPlan Monte Carlo Algorithm For Lung Stereotactic Ablative Radiotherapy (SABR)
    Badkul, R.
    Pokhrel, D.
    Jiang, H.
    Wang, F.
    Kumar, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [45] A case for development of stereotactic ablative body radiotherapy (SABR) for lung cancer at Aberdeen
    Stilwell, C.
    Steven, E.
    Sharma, R. N.
    Bissett, D.
    Shrimali, R. K.
    LUNG CANCER, 2013, 79 : S58 - S59
  • [46] Perirectal Spacer Gel for Men With Prostate Cancer Receiving IMRT Reply
    Mariados, Neil
    Hamstra, Daniel A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (04): : 937 - 939
  • [47] Dosimetric predictors of toxicity and quality of life following prostate stereotactic ablative radiotherapy
    Alayed, Yasir
    Davidson, Melanie
    Quon, Harvey
    Cheung, Patrick
    Chu, William
    Chung, Hans T.
    Vesprini, Danny
    Ong, Aldrich
    Chowdhury, Amit
    Liu, Stanley K.
    Panjwani, Dilip
    Helou, Joelle
    Musunuru, Hima B.
    Pang, Geordi
    Korol, Renee
    Ravi, Ananth
    McCurdy, Boyd
    Zhang, Liying
    Mamedov, Alexandre
    Deabreu, Andrea
    Commisso, Angela
    Commisso, Kristina
    D'Alimonte, Laura
    Ho, Ling
    Bhounr, Zeeba
    Loblaw, Andrew
    RADIOTHERAPY AND ONCOLOGY, 2020, 144 : 135 - 140
  • [48] Dosimetric and patient correlates of quality of life after prostate stereotactic ablative radiotherapy
    Elias, Evelyn
    Helou, Joelle
    Zhang, Liying
    Cheung, Patrick
    Deabreu, Andrea
    D'Alimonte, Laura
    Sethukavalan, Perakaa
    Mamedov, Alexandre
    Cardoso, Marlene
    Loblaw, Andrew
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) : 83 - 88
  • [49] Stereotactic ablative body radiotherapy in patients with prostate cancer
    Loblaw, Andrew
    Liu, Stanley
    Cheung, Patrick
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2018, 7 (03) : 330 - 340
  • [50] Stereotactic ablative Radiotherapy in Patients with oligometastatic Prostate Cancer
    Lorenz, Judith
    AKTUELLE UROLOGIE, 2021, 52 (01) : 22 - 22