The dosimetric advantages of perirectal hydrogel spacer in men with localized prostate cancer undergoing stereotactic ablative radiotherapy (SABR)

被引:2
|
作者
Sturt, Philippa [1 ]
Suh, Yae-Eun [2 ]
Khoo, Vincent [2 ]
机构
[1] Royal Marsden NHS Fdn Trust, Dept Phys, London SW3 6JJ, England
[2] Royal Marsden NHS Fdn Trust, Dept Clin Oncol, London SW3 6JJ, England
关键词
SABR; SBRT; Prostate; Hydrogel spacer; CyberKnife; Radiotherapy;
D O I
10.1016/j.meddos.2022.02.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To evaluate the dosimetric differences for patients receiving a perirectal hydrogel spacer (PR-HS) using SpaceOAR undergoing stereotactic ablative radiotherapy (SABR) for localized prostate cancer with the CyberKnife VSI system. Gold fiducial markers and a PR-HS was inserted in 22 consecutive patients with histologically confirmed localized prostate cancer. For planning comparison, dosimetry from the clinical plans was compared against replans based on a simulated rectum volume designed to recreate a clinically appropriate spacer-less anatomy for each patient. Both sets were planned to 36.25 Gy in 5 fractions using the treatment planning system associated with the CyberKnife VSI system. The aim was to ensure equivalent target coverage for both plans and to evaluate doses to the organs-at-risk (OARs): rectum, bladder and penile bulb. The median PR-HS implant volume was 11.2 cc (range 8.8 to 14.9 cc). The maximal median perirectal separation was 15.5 mm (10.5 to 20.7 mm). Statistically significant reductions were noted for the 3 OARs, with no statistically significant difference in planning target volumes or clinical target volume coverage. All rectal dose constraints were significantly improved in the PR-HS plans with a percentage dose difference of at least 24% (rectum V-18.(1Gy) (%)) to 60.5% (rectum V-36Gy (cc)). The bladder and penile bulb dose constraints parameters were also significantly improved: the bladder V-37Gy was reduced by 17.1%, V-18(.1Gy) was reduced by 4.2%; the penile bulb D-50(%) was reduced by 7.7%. The use of PR-HS was able to significantly reduce planned dose to the rectum, bladder and penile bulb with SABR techniques associated with the CyberKnife VSI system. (C) 2022 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:173 / 176
页数:4
相关论文
共 50 条
  • [31] Stereotactic Ablative Radiotherapy (SABR) for Prostate Cancer - an Analysis of 500 Consecutive Patients Treated at a Single Institution
    Miszczyk, L.
    Namysl-Kaletka, A. J.
    Napieralska, A.
    Kraszkiewicz, M.
    Miszczyk, M.
    Wozniak, G.
    Stapor-Fudzinska, M.
    Glowacki, G.
    Tukiendorf, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E295 - E295
  • [32] Relationship between hydrogel spacer distribution and dosimetric parameters in linear-accelerator-based stereotactic body radiotherapy for prostate cancer
    Ohira, Shingo
    Yamashita, Hideomi
    Minamitani, Masanari
    Sawayanagi, Subaru
    Ogita, Mami
    Imae, Toshikazu
    Katano, Atsuto
    Nozawa, Yuki
    Ohta, Takeshi
    Nawa, Kanabu
    Nishio, Teiji
    Koizumi, Masahiko
    Nakagawa, Keiichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (06):
  • [33] Phase I Dose-Escalation Trial of Stereotactic Ablative Body Radiotherapy (SAbR) for Men with High-Risk Prostate Cancer
    Salamekh, S.
    Desai, N. B.
    Folkert, M. R.
    Garant, A.
    Mannala, S.
    Mohamad, O.
    Choy, H.
    Roehrborn, C.
    Lotan, Y.
    Timmerman, R. D.
    Hannan, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E869 - E869
  • [34] Hydrogel Spacer Prospective Multicenter Randomized Controlled Pivotal Trial: Dosimetric and Clinical Effects of Perirectal Spacer Application in Men Undergoing Prostate Image Guided Intensity Modulated Radiation Therapy
    Mariados, Neil
    Sylvester, John
    Shah, Dhiren
    Karsh, Lawrence
    Hudes, Richard
    Beyer, David
    Kurtzman, Steven
    Bogart, Jeffrey
    Hsi, R. Alex
    Kos, Michael
    Ellis, Rodney
    Logsdon, Mark
    Zimberg, Shawn
    Forsythe, Kevin
    Zhang, Hong
    Soffen, Edward
    Francke, Patrick
    Mantz, Constantine
    Rossi, Peter
    DeWeese, Theodore
    Hamstra, Daniel A.
    Bosch, Walter
    Gay, Hiram
    Michalski, Jeff
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 92 (05): : 971 - 977
  • [35] Hydrogel spacer distribution within the perirectal space in patients undergoing radiotherapy for prostate cancer: Impact of spacer symmetry on rectal dose reduction and the clinical consequences of hydrogel infiltration into the rectal wall
    Fischer-Valuck, Benjamin W.
    Chundury, Anupama
    Gay, Hiram
    Bosch, Walter
    Michalski, Jeff
    PRACTICAL RADIATION ONCOLOGY, 2017, 7 (03) : 195 - 202
  • [36] SpaceOAR hydrogel spacer injection prior to stereotactic body radiation therapy for men with localized prostate cancer A systematic review
    Payne, Heather A.
    Pinkawa, Michael
    Peedell, Clive
    Bhattacharyya, Samir K.
    Woodward, Emily
    Miller, Larry E.
    MEDICINE, 2021, 100 (49)
  • [37] Stereotactic Body Radiotherapy Using a Hydrogel Spacer for Localized Prostate Cancer: A Dosimetric Study Between Tomotherapy With the Newly-Developed Tumor-Tracking System and CyberKnife
    Manabe, Y.
    Hashimoto, S.
    Mukouyama, H.
    Shibamoto, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E277 - E277
  • [38] Stereotactic body radiotherapy using a hydrogel spacer for localized prostate cancer: A dosimetric comparison between tomotherapy with the newly-developed tumor-tracking system and cyberknife
    Manabe, Yoshihiko
    Hashimoto, Seiji
    Mukouyama, Hideki
    Shibamoto, Yuta
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (10): : 66 - 72
  • [39] Two StereoTactic Ablative Radiotherapy Treatments for Localized Prostate Cancer (2STAR)
    Alayed, Y.
    Cheung, P.
    Chu, W.
    Chung, H.
    Davidson, M.
    Ravi, A.
    Helou, J.
    Zhang, L.
    Mamedov, A.
    Commisso, A.
    Commisso, K.
    Loblaw, A.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S441 - S441
  • [40] Quality of Life and Symptoms in Patients Undergoing Stereotactic Ablative Body Radiotherapy (SABR) for Early Stage Lung Cancer
    Gray, C.
    Wingate, E.
    Ghafoor, Q.
    CLINICAL ONCOLOGY, 2018, 30 (06) : E56 - E56