Three-dimensional ion mobility TOFMS analysis of electrosprayed biomolecules

被引:293
|
作者
Hoaglund, CS [1 ]
Valentine, SJ [1 ]
Sporleder, CR [1 ]
Reilly, JP [1 ]
Clemmer, DE [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
D O I
10.1021/ac980059c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion mobility/mass spectrometry technique has been developed to record mass-resolved ion mobility distributions for multiple ions simultaneously. The approach involves a new instrument that couples an electrospray ion source to an injected-ion drift tube/time-of-flight mass spectrometer. Individual components in a mixture of ions are separated by mobility differences in a drift tube and subsequently dispersed by mass-to-charge ratios in a time-of-flight instrument. Flight times in the mass spectrometer are much shorter than residence times in the drift tube, making it possible to record mass-resolved ion mobilities for all ions simultaneously. The result is a three-dimensional spectrum that contains collision cross section, mass-to-charge, and ion abundance information. The instrument and data acquisition system are described. Examples of combined ion mobility/time-of-flight data are presented for distributions of electrosprayed bradykinin and ubiquitin ions.
引用
收藏
页码:2236 / 2242
页数:7
相关论文
共 50 条
  • [41] Towards the three-dimensional field ion microscope
    Vurpillot, F.
    Gilbert, M.
    Deconihout, B.
    [J]. SURFACE AND INTERFACE ANALYSIS, 2007, 39 (2-3) : 273 - 277
  • [42] Three-dimensional ion micro-tomography
    Sakellariou, A
    Jamieson, DN
    Legge, GJF
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 211 - 218
  • [43] Point-group symmetry detection in three-dimensional charge density of biomolecules
    Reboul, Cyril F.
    Kiesewetter, Simon
    Elmlund, Dominika
    Elmlund, Hans
    [J]. BIOINFORMATICS, 2020, 36 (07) : 2237 - 2243
  • [44] Intra-observer reliability in three-dimensional kinematic analysis of sacroiliac joint mobility
    da Veiga, Thiago Rebello
    da Silva, Andre Custodio
    Gomes da Silva, Rodrigo Teixeira
    Machado Carvalho, Sandro Luiz
    Orsini, Marco
    Silva, Julio Guilherme
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (04) : 1001 - 1004
  • [45] Mobility modeling and traffic analysis in three-dimensional high-rise building environments
    Kim, TS
    Kwon, JK
    Sung, DK
    [J]. IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2000, 49 (05) : 1633 - 1640
  • [46] Arm waving in stylophoran echinoderms: three-dimensional mobility analysis illuminates cornute locomotion
    Clark, Elizabeth G.
    Hutchinson, John R.
    Bishop, Peter J.
    Briggs, Derek E. G.
    [J]. ROYAL SOCIETY OPEN SCIENCE, 2020, 7 (06):
  • [47] A Trial to Predict Interactions between Proteins and Biomolecules Based on Their Three-dimensional Structures
    Yura, Kei
    [J]. YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2008, 128 (11): : 1547 - 1555
  • [48] Ion mobility measurements and their applications to clusters and biomolecules
    Clemmer, DE
    Jarrold, MF
    [J]. JOURNAL OF MASS SPECTROMETRY, 1997, 32 (06): : 577 - 592
  • [49] Three-dimensional tracking and analysis of ion channel signals across dendritic arbors
    Ginger, Melanie
    Broser, Philip
    Frick, Andreas
    [J]. FRONTIERS IN NEURAL CIRCUITS, 2013, 7
  • [50] Three-dimensional analysis of coalesced bainite using focused ion beam tomography
    Keehan, E.
    Karisson, L.
    Bhadeshia, H. K. D. H.
    Thuvander, Mattias
    [J]. MATERIALS CHARACTERIZATION, 2008, 59 (07) : 877 - 882