Three-dimensional ion micro-tomography

被引:26
|
作者
Sakellariou, A [1 ]
Jamieson, DN [1 ]
Legge, GJF [1 ]
机构
[1] Univ Melbourne, Sch Phys, Microanalyt Res Ctr, Parkville, Vic 3010, Australia
关键词
STIM tomography; PIXE tomography;
D O I
10.1016/S0168-583X(01)00618-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The technique of ion micro-tomography (IMT) provides three-dimensional distribution information about a sample's mass density and elemental composition. The required data are obtained by doing a scanning transmission ion microscopy (STIM) tomography experiment followed by a particle-induced X-ray emission (PIXE) tomography experiment. The experiment times have been vastly reduced now that data are collected with MicroDAS, the new fast data acquisition system. Moreover, the experiment is easier to perform because sample manipulation is automated via computer control. To obtain comparable spatial resolutions between the STIM and PIXE data, the PIXE tomography experiment is performed by implementing a large solid angle between the sample and X-ray detector. To correct for the inherent three-dimensional nature of such an experimental setup, a specially developed tomographic reconstruction technique is used to combine the STIM and PIXE tomography data sets to create an accurate quantitative tomogram of the sample. The efficacy of the entire IMT process is tested with a characterised "standard" sample. The calculated data agree well with the quantitative and structural information known about the sample. To interpret the three-dimensional distribution information, a special volume rendering program is used to visualise various aspects of the tomogram. Each aspect is colour coded to facilitate the easy visualisation of multiple complex three-dimensional structures. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 50 条
  • [1] Micro-tomography based Geometry Modeling of Three-Dimensional Braided Composites
    Guodong Fang
    Chenghua Chen
    Shenggang Yuan
    Songhe Meng
    Jun Liang
    [J]. Applied Composite Materials, 2018, 25 : 469 - 483
  • [2] Micro-tomography based Geometry Modeling of Three-Dimensional Braided Composites
    Fang, Guodong
    Chen, Chenghua
    Yuan, Shenggang
    Meng, Songhe
    Liang, Jun
    [J]. APPLIED COMPOSITE MATERIALS, 2018, 25 (03) : 469 - 483
  • [3] THREE-DIMENSIONAL MICRO-STRUCTURES OF DUST AGGREGATE BY RANDOM BALLISTIC DEPOSITION USING MICRO-TOMOGRAPHY
    Imai, Y.
    Tsuchiyama, A.
    Blum, J.
    Uesugi, K.
    Takeuchi, A.
    Nakano, T.
    Uesugi, M.
    [J]. METEORITICS & PLANETARY SCIENCE, 2011, 46 : A107 - A107
  • [4] Three-dimensional visualisation of soft biological structures by X-ray computed micro-tomography
    Shearer, Tom
    Bradley, Robert S.
    Hidalgo-Bastida, L. Araida
    Sherratt, Michael J.
    Cartmell, Sarah H.
    [J]. JOURNAL OF CELL SCIENCE, 2016, 129 (13) : 2483 - 2492
  • [5] Three-dimensional study of a fretting crack using synchrotron X-ray micro-tomography
    Proudhon, H.
    Buffiere, J-Y
    Fouvry, S.
    [J]. ENGINEERING FRACTURE MECHANICS, 2007, 74 (05) : 782 - 793
  • [6] Non-destructive three-dimensional evaluation of a polymer sponge by micro-tomography using synchrotron radiation
    Müller, B
    Beckmann, F
    Huser, M
    Maspero, F
    Székely, G
    Ruffieux, K
    Thurner, P
    Wintermantel, E
    [J]. BIOMOLECULAR ENGINEERING, 2002, 19 (2-6): : 73 - 78
  • [7] Three-Dimensional Analysis of MgB2 Wire by use of X-ray Micro-Tomography
    Inoue, Masayoshi
    Tatara, Hiroshi
    Harada, Kazutaka
    Higashikawa, Kohei
    Ye, Shujun
    Matsumoto, Akiyoshi
    Kumakura, Hiroaki
    Kiss, Takanobu
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)
  • [8] First results on ion micro-tomography at LIPSION
    Rothermel, M.
    Reinert, T.
    Andrea, T.
    Butz, T.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (11-12): : 2001 - 2005
  • [9] Investigating the Three-Dimensional Microstructural Characteristics of Lithium-Sulfur Electrodes with X-Ray Micro-Tomography
    Tan, C.
    Daemi, S. R.
    Brett, D. J. L.
    Shearing, P. R.
    [J]. SELECTED PROCEEDINGS FROM THE 231ST ECS MEETING, 2017, 77 (11): : 447 - 455
  • [10] Three-dimensional assessment of bone architecure and turnover with computed micro-tomography and laser scanning confocal microscopy.
    Prevrhal, S
    Jiang, Y
    Zhao, J
    Genant, HK
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 : S464 - S464