Three-dimensional ion micro-tomography

被引:26
|
作者
Sakellariou, A [1 ]
Jamieson, DN [1 ]
Legge, GJF [1 ]
机构
[1] Univ Melbourne, Sch Phys, Microanalyt Res Ctr, Parkville, Vic 3010, Australia
关键词
STIM tomography; PIXE tomography;
D O I
10.1016/S0168-583X(01)00618-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The technique of ion micro-tomography (IMT) provides three-dimensional distribution information about a sample's mass density and elemental composition. The required data are obtained by doing a scanning transmission ion microscopy (STIM) tomography experiment followed by a particle-induced X-ray emission (PIXE) tomography experiment. The experiment times have been vastly reduced now that data are collected with MicroDAS, the new fast data acquisition system. Moreover, the experiment is easier to perform because sample manipulation is automated via computer control. To obtain comparable spatial resolutions between the STIM and PIXE data, the PIXE tomography experiment is performed by implementing a large solid angle between the sample and X-ray detector. To correct for the inherent three-dimensional nature of such an experimental setup, a specially developed tomographic reconstruction technique is used to combine the STIM and PIXE tomography data sets to create an accurate quantitative tomogram of the sample. The efficacy of the entire IMT process is tested with a characterised "standard" sample. The calculated data agree well with the quantitative and structural information known about the sample. To interpret the three-dimensional distribution information, a special volume rendering program is used to visualise various aspects of the tomogram. Each aspect is colour coded to facilitate the easy visualisation of multiple complex three-dimensional structures. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 50 条
  • [41] Three-dimensional analysis of micro defect morphologies in cement-based materials using focused ion beam tomography
    WAN KeShu SUN Wei TANG ChunKai RONG ZhiDan Jiangsu Key Laboratory of Construction MaterialsNanjing China School of Materials Science and EngineeringSoutheast UniversityNanjing China
    Science China(Technological Sciences), 2012, 55 (06) : 1539 - 1544
  • [42] Three-dimensional analysis of micro defect morphologies in cement-based materials using focused ion beam tomography
    Wan Keshu
    Sun Wei
    Tang ChunKai
    Rong ZhiDan
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2012, 55 (06) : 1539 - 1544
  • [43] Three-dimensional analysis of coalesced bainite using focused ion beam tomography
    Keehan, E.
    Karisson, L.
    Bhadeshia, H. K. D. H.
    Thuvander, Mattias
    MATERIALS CHARACTERIZATION, 2008, 59 (07) : 877 - 882
  • [44] Advances in Focused Ion Beam Tomography for Three-Dimensional Characterization in Materials Science
    Mura, Francesco
    Cognigni, Flavio
    Ferroni, Matteo
    Morandi, Vittorio
    Rossi, Marco
    MATERIALS, 2023, 16 (17)
  • [45] Three-dimensional diffractive acoustic tomography
    Luca Menozzi
    Tri Vu
    Aidan J. Canning
    Harshal Rawtani
    Carlos Taboada
    Marie Elise Abi Antoun
    Chenshuo Ma
    Jesse Delia
    Van Tu Nguyen
    Soon-Woo Cho
    Jianing Chen
    Theresa Charity
    Yirui Xu
    Phuong Tran
    Jun Xia
    Gregory M. Palmer
    Tuan Vo-Dinh
    Liping Feng
    Junjie Yao
    Nature Communications, 16 (1)
  • [46] Airborne Three-Dimensional Cloud Tomography
    Levis, Aviad
    Schechner, Yoav Y.
    Aides, Amit
    Davis, Anthony B.
    2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2015, : 3379 - 3387
  • [47] Three-dimensional electrical impedance tomography
    Metherall, P
    Barber, DC
    Smallwood, RH
    Brown, BH
    NATURE, 1996, 380 (6574) : 509 - 512
  • [48] Three-dimensional fluorescence lifetime tomography
    Godavarty, A
    Sevick-Muraca, EM
    Eppstein, MJ
    MEDICAL PHYSICS, 2005, 32 (04) : 992 - 1000
  • [49] Three-dimensional tomography of interplanetary disturbances
    Jackson, BV
    Hick, PP
    SOLAR AND SPACE WEATHER RADIOPHYSICS: CURRENT STATUS AND FUTURE DEVELOPMENTS, 2004, 314 : 355 - 386