Non-destructive three-dimensional evaluation of a polymer sponge by micro-tomography using synchrotron radiation

被引:66
|
作者
Müller, B
Beckmann, F
Huser, M
Maspero, F
Székely, G
Ruffieux, K
Thurner, P
Wintermantel, E
机构
[1] Swiss Fed Inst Technol, CH-8952 Schlieren, Switzerland
[2] DESY, Hamburger Synchrontronstschlungslab HASYLAB, D-22607 Hamburg, Germany
[3] Swiss Fed Inst Technol, Inst Bildverarbeitung, CH-8092 Zurich, Switzerland
[4] Degradable Solut AG, CH-9852 Schlieren, Switzerland
[5] Eidgenoss Mat Prufungs & Forschungsanstalt, CH-8600 Dubendorf, Switzerland
来源
BIOMOLECULAR ENGINEERING | 2002年 / 19卷 / 2-6期
关键词
biodegradable scaffold; X-ray microtomography; synchrotron radiation; three-dimensional image analysis; porosity;
D O I
10.1016/S1389-0344(02)00014-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
X-ray micro-tomography, a non-destructive technique is used to uncover the complex 3-D micro-architecture of a degradable polymer sponge designed for bone augmentation. The measurements performed at HASYLAB at DESY are based on a synchrotron radiation source resulting in a spatial resolution of about 5.4 mum. In the present communication we report the quantitative analysis of the porosity and of the pore architecture. First, we elucidate that synchrotron radiation at the photon energy of 9 keV has an appropriate cross section for this low-weight material. Modifications in sponge micro-architecture during measurement are not detected. Second, the treatment of the data, an amount of 2.5 Gbyte to generate binary data is described. We compare the 3-D with the 2-D analysis in a quantitative manner. The obtained values for the mean distance to material within the sponge calculated from 2-D and 3-D data of the whole tomogram differ significantly: 12.5 mum for 3-D and 17.6 mum for 2-D analysis. If the pores exhibit a spherical shape as frequently found, the derived mean pore diameter, however, is overestimated only by 6% in the 2-D image analysis with respect to the 3-D evaluation. This approach can be applied to different porous biomaterials and composites even in a hydrated state close to physiological conditions, where any surface preparation artifact is avoided. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 50 条
  • [1] Non-destructive three-dimensional evaluation of biocompatible materials by microtomography using synchrotron radiation
    Müller, B
    Thurner, P
    Beckmann, F
    Weitkamp, T
    Rau, C
    Bernhardt, R
    Karamuk, E
    Eckert, L
    Brandt, J
    Buchloh, S
    Wintermantel, E
    Scharnweber, D
    Worch, H
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 178 - 188
  • [2] Three-dimensional non-destructive soft-tissue visualization with X-ray staining micro-tomography
    Silva, Juliana Martins de S. e
    Zanette, Irene
    Noel, Peter B.
    Cardoso, Mateus B.
    Kimm, Melanie A.
    Pfeiffer, Franz
    SCIENTIFIC REPORTS, 2015, 5
  • [3] Three-dimensional non-destructive soft-tissue visualization with X-ray staining micro-tomography
    Juliana Martins de S. e Silva
    Irene Zanette
    Peter B. Noël
    Mateus B. Cardoso
    Melanie A. Kimm
    Franz Pfeiffer
    Scientific Reports, 5
  • [4] Three-dimensional ion micro-tomography
    Sakellariou, A
    Jamieson, DN
    Legge, GJF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 211 - 218
  • [5] Three-dimensional study of a fretting crack using synchrotron X-ray micro-tomography
    Proudhon, H.
    Buffiere, J-Y
    Fouvry, S.
    ENGINEERING FRACTURE MECHANICS, 2007, 74 (05) : 782 - 793
  • [6] Three-dimensional thermography for non-destructive testing and evaluation
    Akhloufi, Moulay A.
    Guyon, Yannis
    Castanedo, Clemente-Ibarra
    Bendada, Abdelhakim
    QUANTITATIVE INFRARED THERMOGRAPHY JOURNAL, 2017, 14 (01) : 79 - 106
  • [7] Three-dimensional non-destructive optical evaluation of laser-processing performance using optical coherence tomography
    Kim, Youngseop
    Choi, Eun Sco
    Kwak, Wooseop
    Shin, Yongjin
    Jung, Woonggyu
    Ahn, Yeh-Chan
    Chen, Zhongping
    OPTICS AND LASER TECHNOLOGY, 2008, 40 (04): : 625 - 631
  • [8] Three-dimensional and non-destructive characterization of nerves inside conduits using laboratory-based micro computed tomography
    Bikis, Christos
    Thalmann, Peter
    Degrugillier, Lucas
    Schulz, Georg
    Mueller, Bert
    Kalbermatten, Daniel F.
    Madduri, Srinivas
    Hieber, Simone E.
    JOURNAL OF NEUROSCIENCE METHODS, 2018, 294 : 59 - 66
  • [9] Three-dimensional non-destructive visualization of teeth enamel microcracks using X-ray micro-computed tomography
    Irma Dumbryte
    Arturas Vailionis
    Edvinas Skliutas
    Saulius Juodkazis
    Mangirdas Malinauskas
    Scientific Reports, 11
  • [10] Three-dimensional non-destructive visualization of teeth enamel microcracks using X-ray micro-computed tomography
    Dumbryte, Irma
    Vailionis, Arturas
    Skliutas, Edvinas
    Juodkazis, Saulius
    Malinauskas, Mangirdas
    SCIENTIFIC REPORTS, 2021, 11 (01)