Electrochemical noise analysis of cathodically protected steel reinforcement in concrete using carbon fiber sheet as anode

被引:6
|
作者
Hu, Jiyue [1 ]
Wang, Siyu [1 ]
Lu, Yiyan [1 ]
Li, Shan [1 ]
机构
[1] Wuhan Univ, Sch Civil Engn, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Corrosion; Cathodic protection; Carbon fiber sheet; Electrochemical noise; CORROSION BEHAVIOR; PITTING CORROSION; CEMENT MORTAR; INITIATION; REMOVAL;
D O I
10.1016/j.conbuildmat.2021.125474
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an efficiency and mechanism analysis of impressed current cathodic protection (ICCP) for corroded steel reinforcements in concrete by means of electrochemical noise (EN), which is an advanced technique that allows real-time monitoring without any disturbance. The considered variables include protection method (non-protection, ICCP) and current density of ICCP (30 mA/m2, 90 mA/m2). In the cases of ICCP, carbon fiber sheet is adopted as the anode thanks to its good electrochemical properties and durability. Electrochemical potential noise (EPN) and electrochemical current noise (ECN) of steel reinforcement in concrete are measured every 30 d during the 120-d exposure period and analyzed from the perspectives of time and frequency domains. The results show that ICCP treatment with a current density of 30 mA/m2 leads to slighter fluctuations in ECN signals, an improvement in noise resistance Rn, and decreases in the low frequency plateau WL in power density diagram (PSD) of ECN signals. It indicates that the corrosion of steel is alleviated. However, the results of the specimen protected with a current density of 90 mA/m2 are the opposite, which is overprotected and hydrogen corrosion may happen. Compared to the specimen with no protection, the specimen treated with 30 mA/m2 ICCP shows an evident increase in energy proportion of d1-d3 wavelet crystals. Additionally, with increasing the treatment duration, the energy proportion of d1-d3 wavelet crystals increases. This illustrates that ICCP is more effective in inhibiting general corrosion than pitting corrosion. Extra caution should be paid to EPN signals of specimens subjected to ICCP, namely polarization, because EPN signals may anomalously exhibit severer fluctuations as a result of insufficient depolarization. It is suggested to use ECN signals instead of EPN signals to analyze the corrosion behavior of specimens subjected to ICCP.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Electrochemical Degradation of Ammonia Nitrogen in Mariculture Wastewater Using an Activated Carbon Fiber Composite Anode
    Hang Xiaocai Yu
    Jinghua Yang
    Liping Liu
    Meichen Wang
    Surface Engineering and Applied Electrochemistry, 2019, 55 : 587 - 594
  • [42] Electrochemical noise analysis of cathodically polarised AISI 4140 steel.: II.: Identification of potential fluctuation sources for unstressed electrodes
    Benzaïd, A
    Huet, F
    Jérôme, M
    Wenger, F
    Gabrielli, C
    Galland, J
    ELECTROCHIMICA ACTA, 2002, 47 (27) : 4325 - 4332
  • [43] Study of the copper anode passivation by electrochemical noise analysis using spectral and wavelet transforms
    Lafront, Anne-Marie
    Safizadeh, Fariba
    Ghali, Edward
    Houlachi, Georges
    ELECTROCHIMICA ACTA, 2010, 55 (07) : 2505 - 2512
  • [44] Noise removal by cluster analysis after long time AE corrosion monitoring of steel reinforcement in concrete
    Calabrese, L.
    Campanella, G.
    Proverbio, E.
    CONSTRUCTION AND BUILDING MATERIALS, 2012, 34 : 362 - 371
  • [45] Investigating the feasibility of using carbon fiber tapes as reinforcement for 3D concrete printing
    Scheurer, Martin
    Quenzel, Philipp
    Nölke, Peter
    Reuter-Schniete, Jonas
    Gries, Thomas
    Civil Engineering Design, 2021, 3 (04) : 136 - 142
  • [46] Design of multiphase carbon fiber reinforcement of crack existing concrete structures using topology optimization
    Nguyen, Anh P.
    Banh, Thanh T.
    Lee, Dongkyu
    Lee, Jaehong
    Kang, Joowon
    Shin, Soomi
    STEEL AND COMPOSITE STRUCTURES, 2018, 29 (05): : 635 - 645
  • [47] Feasibility of reinforcement in Brazilian concrete highway bridges using carbon fiber-reinforced polymer
    Medeiros, A.
    Mazer, W.
    Rossigali, C. E.
    Bittencourt, T. N.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 354 - 357
  • [48] Tensile and bending stress analysis of fiber sheet and steel plate-reinforced concrete beams with cracks
    Zeng, Q. D.
    Wang, G. Y.
    ADVANCES IN HETEROGENEOUS MATERIAL MECHANICS 2008, 2008, : 1301 - 1305
  • [49] Laboratory testing and calculation analysis of reinforcement for prestressed concrete cylinder pipe with compound carbon fiber
    Dong X.
    Li M.
    Sun Z.
    Ma Y.
    Shuili Xuebao/Journal of Hydraulic Engineering, 2019, 50 (06): : 780 - 786
  • [50] Seismic performance evaluation and improvement for damaged reinforcement concrete piers using a fiber steel composite plate
    Han, Kyoungbong
    Cho, Dooyong
    Kim, Jinsoo
    JOURNAL OF VIBROENGINEERING, 2016, 18 (07) : 4574 - 4582