Electrochemical noise analysis of cathodically protected steel reinforcement in concrete using carbon fiber sheet as anode

被引:6
|
作者
Hu, Jiyue [1 ]
Wang, Siyu [1 ]
Lu, Yiyan [1 ]
Li, Shan [1 ]
机构
[1] Wuhan Univ, Sch Civil Engn, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Corrosion; Cathodic protection; Carbon fiber sheet; Electrochemical noise; CORROSION BEHAVIOR; PITTING CORROSION; CEMENT MORTAR; INITIATION; REMOVAL;
D O I
10.1016/j.conbuildmat.2021.125474
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an efficiency and mechanism analysis of impressed current cathodic protection (ICCP) for corroded steel reinforcements in concrete by means of electrochemical noise (EN), which is an advanced technique that allows real-time monitoring without any disturbance. The considered variables include protection method (non-protection, ICCP) and current density of ICCP (30 mA/m2, 90 mA/m2). In the cases of ICCP, carbon fiber sheet is adopted as the anode thanks to its good electrochemical properties and durability. Electrochemical potential noise (EPN) and electrochemical current noise (ECN) of steel reinforcement in concrete are measured every 30 d during the 120-d exposure period and analyzed from the perspectives of time and frequency domains. The results show that ICCP treatment with a current density of 30 mA/m2 leads to slighter fluctuations in ECN signals, an improvement in noise resistance Rn, and decreases in the low frequency plateau WL in power density diagram (PSD) of ECN signals. It indicates that the corrosion of steel is alleviated. However, the results of the specimen protected with a current density of 90 mA/m2 are the opposite, which is overprotected and hydrogen corrosion may happen. Compared to the specimen with no protection, the specimen treated with 30 mA/m2 ICCP shows an evident increase in energy proportion of d1-d3 wavelet crystals. Additionally, with increasing the treatment duration, the energy proportion of d1-d3 wavelet crystals increases. This illustrates that ICCP is more effective in inhibiting general corrosion than pitting corrosion. Extra caution should be paid to EPN signals of specimens subjected to ICCP, namely polarization, because EPN signals may anomalously exhibit severer fluctuations as a result of insufficient depolarization. It is suggested to use ECN signals instead of EPN signals to analyze the corrosion behavior of specimens subjected to ICCP.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Electrochemical noise analysis of carbon steel in simulated concrete pore solution affected by CO2 and SO2 using wavelet transform
    Allahkaram, Saeed Reza
    Khodayari, Mehdi
    ANTI-CORROSION METHODS AND MATERIALS, 2008, 55 (05) : 250 - 256
  • [22] Electrochemical noise of copper anode behaviour in industrial electrolyte using wavelet analysis
    Safizadeh, F.
    Ghali, E.
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2013, 23 (06) : 1854 - 1862
  • [23] Cathodic protection of steel reinforced concrete facilitated by using carbon fiber reinforced mortar or concrete
    Compos. Mat. Research Laboratory, Stt. Univ. of New York at Buffalo, Buffalo, NY 14260-4400, United States
    Cem Concr Res, 5 (649-656):
  • [24] Cathodic protection of steel reinforced concrete facilitated by using carbon fiber reinforced mortar or concrete
    Hou, JY
    Chung, DDL
    CEMENT AND CONCRETE RESEARCH, 1997, 27 (05) : 649 - 656
  • [25] Electrochemical noise analysis of cathodically polarised AISI 4140 steel.: III.: Influence of hydrogen absorption for stressed electrodes
    Benzaïd, A
    Huet, F
    Jérôme, M
    Wenger, F
    Gabrielli, C
    Galland, J
    ELECTROCHIMICA ACTA, 2002, 47 (27) : 4333 - 4338
  • [26] Stressing State Analysis of Reinforcement Concrete Beams Strengthened with Carbon Fiber Reinforced Plastic
    Jie Huang
    Jun Shi
    Hengheng Xiao
    Jiyang Shen
    Baisong Yang
    International Journal of Concrete Structures and Materials, 2020, 14
  • [27] Stressing State Analysis of Reinforcement Concrete Beams Strengthened with Carbon Fiber Reinforced Plastic
    Huang, Jie
    Shi, Jun
    Xiao, Hengheng
    Shen, Jiyang
    Yang, Baisong
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2020, 14 (01)
  • [28] Weld bead reinforcement on cold rolled carbon steel sheet joint using ColdArc technology
    Sabdin, Saiful Din
    Hussein, Nur Izan Syahriah
    Sued, Mohammad Kamil
    Ayof, Mohamad Nizam
    Ayob, Muhammed Syameel
    Rahim, Mohd Aidil Shah Abdul
    PROCEEDINGS OF MECHANICAL ENGINEERING RESEARCH DAY 2018 (MERD), 2018, : 197 - 198
  • [29] Factors affecting the measurements and analysis of electrochemical noise during carbon steel corrosion
    Cheng, YF
    Luo, JL
    BULLETIN OF ELECTROCHEMISTRY, 2001, 17 (03): : 97 - 104
  • [30] Electrochemical noise analysis for estimation of corrosion rate of carbon steel in crude oil
    Mahjani, Mohammad Ghassem
    Neshati, Jaber
    Masiha, Hashem Parvaneh
    Jafarian, Majid
    ANTI-CORROSION METHODS AND MATERIALS, 2007, 54 (01) : 27 - 33