Placement of deep brain stimulator electrodes using real-time high-field interventional magnetic resonance imaging

被引:77
|
作者
Martin, AJ
Larson, PS
Ostrem, FL
Sootsman, WK
Talke, P
Weber, OM
Levesque, N
Myers, J
Starr, PA
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Philips Med Syst, Cleveland, OH USA
[3] Univ Calif San Francisco, Dept Neurosurg, San Francisco, CA 94143 USA
[4] Univ Calif San Francisco, Dept Neurol, San Francisco, CA 94143 USA
[5] Image Guided Neurol, Melbourne, FL USA
[6] Univ Calif San Francisco, Dept Anesthesia & Perioperat Med, San Francisco, CA 94143 USA
[7] Univ Calif San Francisco, Dept Nursing, San Francisco, CA 94143 USA
关键词
interventional MR; DBS electrodes; Parkinson's disease; MR fluoroscopy; implants;
D O I
10.1002/mrm.20675
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A methodology is presented for placing deep brain stimulator electrodes under direct MR image guidance. The technique utilized a small, skull-mounted trajectory guide that is optimized for accurate alignment under MR fluoroscopy. Iterative confirmation scans are used to monitor device alignment and brain penetration. The methodology was initially tested in a human skull phantom and proved capable of achieving submillimeter accuracy over a set of 16 separate targets that were accessed. The maximum error that was obtained in this preliminary test was 2 mm, motivating use of the technique in a clinical study. Subsequently, a total of eight deep brain stimulation electrodes were placed in five patients. Satisfactory placement was achieved on the first pass in seven of eight electrodes, while two passes were required with one electrode. Mean error from the intended target on the first pass was 1.0 +/- 0.8 mm (range = 0.1-1.9 mm). All procedures were considered technical successes and there were no intraoperative complications; however, one patient did develop a postoperative infection. Magn Reson Med 54:1107-1114,2005. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1107 / 1114
页数:8
相关论文
共 50 条
  • [21] Safety, efficacy, and functionality of high-field strength interventional magnetic resonance imaging for neurosurgery - Comment
    Fahlbusch, R
    Nimsky, C
    NEUROSURGERY, 2000, 46 (03) : 642 - 642
  • [22] High-field magnetic resonance imaging using solenoid radiofrequency coils
    Vegh, Viktor
    Glaeser, Philipp
    Maillet, Donald
    Cowin, Gary J.
    Reutens, David C.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (08) : 1177 - 1185
  • [23] High-Field Atherosclerotic Plaque Magnetic Resonance Imaging
    Yuan, Chun
    Wang, Jinnan
    Balu, Niranjan
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2012, 22 (02) : 271 - +
  • [24] Safety aspects in high-field magnetic resonance imaging
    Muehlenweg, M.
    Schaefers, G.
    Trattnig, S.
    RADIOLOGE, 2008, 48 (03): : 258 - 267
  • [25] Superconducting array for high-field magnetic resonance imaging
    Wosik, J.
    Xue, L.
    Xie, L.-M.
    Kamel, M. R.
    Nesteruk, K.
    Bankson, James A.
    APPLIED PHYSICS LETTERS, 2007, 91 (18)
  • [26] High-field magnetic resonance techniques for brain research
    Kim, DS
    Garwood, M
    CURRENT OPINION IN NEUROBIOLOGY, 2003, 13 (05) : 612 - 619
  • [27] Steps towards the connectome: interrogation of brain function and connectivity using high-field magnetic resonance imaging
    Kim, Daeshik
    NEUROSCIENCE RESEARCH, 2010, 68 : E15 - E15
  • [28] A novel composite targeting method using high-field magnetic resonance imaging for subthalamic nucleus deep brain stimulation Clinical article
    Toda, Hiroki
    Sawamoto, Nobukatsu
    Hanakawa, Takashi
    Saiki, Hidemoto
    Matsumoto, Sadayuki
    Okumura, Ryosuke
    Ishikawa, Masatsune
    Fukuyama, Hidenao
    Hashimoto, Nobuo
    JOURNAL OF NEUROSURGERY, 2009, 111 (04) : 737 - 745
  • [29] Reading and controlling human brain activation using real-time functional magnetic resonance imaging
    deCharms, R. Christopher
    TRENDS IN COGNITIVE SCIENCES, 2007, 11 (11) : 473 - 481
  • [30] Optimizing brain tumor resection - High-field interventional MR imaging
    Tummala, RP
    Chu, RM
    Liu, HY
    Truwit, CL
    Hall, WA
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2001, 11 (04) : 673 - +